← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

4C0038000F51353135323934

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 220V · 750W · SSR SSR10DA
QC pad (MAC) : 02813B23751D
Start : 2026-08-11T05:03:02.826559 · End : 2026-08-11T05:15:04.896175 · Duration : 722 s
Received (server) : 2026-08-11T06:02:03
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=750 ssr=SSR10DA lot=20260618 uid=9221AF

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 05:03:03
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=4C0038000F51353135323934
Home X PASS 05:03:28
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 05:04:04
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 05:04:12
Part fan PASS 05:04:14
Hotend fan PASS 05:04:17
Hotend heat 220°C PASS 05:04:17
Bed heat 60°C PASS 05:04:47
Cutter (feed+cut) PASS 05:06:35
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.4234 gap=1.5766 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 05:06:54
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 100mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 05:09:38
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=461.307500 probe at 49.995,339.999 is z=463.665000 Tap drift (diff=2.3575mm) — reset probe at 49.995,339.999 is z=419.772500 Tap drift (diff=43.8925mm) — reset probe at 49.995,339.999 is z=413.130000 Tap drift (diff=6.6425mm) — reset probe at 49.995,339.999 is z=407.305000 Tap drift (diff=5.8250mm) — reset probe at 49.995,339.999 is z=407.450000 Tap drift (diff=0.1450mm) — reset probe at 49.995,339.999 is z=407.467500 Tap drift (diff=0.0175mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 49.995,339.999 is z=407.470000 Tap OK (diff=0.0025mm, stable 3/5) probe at 49.995,339.999 is z=407.472500 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=407.4725 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z tap repeatability PASS 05:14:26 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.1600, 486.1075, 486.1050, 486.0950, 486.1025, 486.1025, 486.0975, 486.1025, 486.1000, 486.1000, 486.1025, 486.1000, 486.1000, 486.1025, 486.0975
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=495.765000 probe at 49.998,339.999 is z=257.500000 Tap drift (diff=238.2650mm) — reset probe at 49.998,339.999 is z=243.002500 Tap drift (diff=14.4975mm) — reset probe at 49.998,339.999 is z=235.755000 Tap drift (diff=7.2475mm) — reset probe at 49.998,339.999 is z=193.695000 Tap drift (diff=42.0600mm) — reset probe at 49.998,339.999 is z=189.012500 Tap drift (diff=4.6825mm) — reset probe at 49.998,339.999 is z=162.922500 Tap drift (diff=26.0900mm) — reset probe at 49.998,339.999 is z=1.095000 Tap drift (diff=161.8275mm) — reset probe at 49.998,339.999 is z=1.130000 Tap drift (diff=0.0350mm) — reset probe at 49.998,339.999 is z=1.137500 Tap OK (diff=0.0075mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 49.998,339.999 is z=1.147500 Tap drift (diff=0.0100mm) — reset probe at 49.998,339.999 is z=1.155000 probe at 49.998,339.999 is z=1.157500 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) probe at 49.998,339.999 is z=1.160000 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=1.1600 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete! probe at 49.998,339.999 is z=486.085000 probe at 49.998,339.999 is z=486.100000 Tap drift (diff=0.0150mm) — reset probe at 49.998,339.999 is z=486.102500 Tap OK (diff=0.0025mm, stable 2/5) probe at 49.998,339.999 is z=486.105000 probe at 49.998,339.999 is z=486.107500
Screws tilt PASS 05:15:04
probe: at 54.997,328.001 bed will contact at z=1.872500 probe: at 54.997,328.001 bed will contact at z=1.895000 probe: at 54.997,328.001 bed will contact at z=1.892500 probe: at 380.001,328.001 bed will contact at z=1.907500 probe: at 380.001,328.001 bed will contact at z=1.922500 probe: at 380.001,328.001 bed will contact at z=1.912500 probe: at 380.001,101.996 bed will contact at z=1.787500 probe: at 380.001,101.996 bed will contact at z=1.797500 probe: at 380.001,101.996 bed will contact at z=1.790000 probe: at 54.997,101.996 bed will contact at z=1.787500 probe: at 54.997,101.996 bed will contact at z=1.827500 probe: at 54.997,101.996 bed will contact at z=1.802500 probe: at 217.505,214.498 bed will contact at z=1.825000 probe: at 217.505,214.498 bed will contact at z=1.840000 probe: at 217.505,214.498 bed will contact at z=1.830000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=1.89250 front right screw : x=397.0, y=298.0, z=1.91250 : adjust CW 00:02 rear right screw : x=397.0, y=72.0, z=1.79000 : adjust CCW 00:12 rear left screw : x=72.0, y=72.0, z=1.80250 : adjust CCW 00:11 middle : x=234.5, y=184.5, z=1.83000 : adjust CCW 00:07