← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

4C003F000F51353135323934

PASS Grade A Grade B
Model : C335 · Batch : 20260618
Heated bed : 220V · 500W · SSR SSR10DA
QC pad (MAC) : 0281E38DE8BE
Start : 2026-07-25T07:56:57.880255 · End : 2026-07-25T08:10:33.885172 · Duration : 816 s
Received (server) : 2026-07-25T08:15:25
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C335 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=500 ssr=SSR10DA lot=20260618 uid=36C6E9

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 07:56:58
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=500;ssr=SSR10DA;lot=20260618;uid=36C6E9 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=4C003F000F51353135323934
Home X PASS 07:57:22
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000
Home Y PASS 07:57:56
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.6062 gap=1.3938 (chauffe, ignore) tap 2: pos=-30.7769 gap=1.2231 (1/4) tap 3: pos=-30.7769 gap=1.2231 (2/4) tap 4: pos=-30.7769 gap=1.2231 (3/4) tap 5: pos=-30.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-30.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 07:58:05
Part fan PASS 07:58:07
Hotend fan PASS 07:58:10
Hotend heat 220°C PASS 07:58:12
Bed heat 60°C PASS 07:58:38
Cutter (feed+cut) PASS 08:00:14
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9847 gap=2.0153 (3/4) tap 5: pos=357.0091 gap=1.9909 fenetre=0.0244/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0244mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1797 gap=1.8203 (chauffe, ignore) tap 2: pos=-30.7769 gap=1.2231 (1/4) tap 3: pos=-30.7769 gap=1.2231 (2/4) tap 4: pos=-30.7769 gap=1.2231 (3/4) tap 5: pos=-30.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-30.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 08:00:24
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 50mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 08:03:31
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=356.9847 gap=2.0153 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=357.0091 gap=1.9909 fenetre=0.0244/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0244mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.5819 gap=1.4181 (chauffe, ignore) tap 2: pos=-30.1797 gap=1.8203 (1/4) tap 3: pos=-30.5941 gap=1.4059 (2/4) tap 4: pos=-30.1797 gap=1.8203 (3/4) tap 5: pos=-30.7769 gap=1.2231 fenetre=0.5972/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.4326 spread=0.5972mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.996,275.995 is z=290.140000 probe at 65.996,275.995 is z=290.130000 Tap OK (diff=0.0100mm, stable 2/5) probe at 65.996,275.995 is z=290.132500 Tap OK (diff=0.0025mm, stable 3/5) probe at 65.996,275.995 is z=290.125000 Tap OK (diff=0.0075mm, stable 4/5) probe at 65.996,275.995 is z=290.137500 Tap drift (diff=0.0125mm) — reset probe at 65.996,275.995 is z=290.127500 probe at 65.996,275.995 is z=290.047500 Tap drift (diff=0.0825mm) — reset probe at 65.996,275.995 is z=290.175000 Tap drift (diff=0.1275mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 65.996,275.995 is z=290.177500 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=290.1750 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete!
Z tap repeatability PASS 08:09:55 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.0575, 385.9425, 385.8875, 385.9100, 385.8950, 385.9025, 385.9050, 385.8975, 385.9025, 385.8975, 385.9025, 385.9025, 385.9000, 385.9000, 385.9025
Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.999,275.995 is z=395.737500 probe at 65.999,275.995 is z=398.490000 Tap rejete (vibration chassis, z=398.4900 > max-z_hop) -> pas de remontee, on poursuit la descente (1) probe at 65.999,275.995 is z=389.175000 probe at 65.999,275.995 is z=149.977500 Tap drift (diff=239.1975mm) — reset probe at 65.999,275.995 is z=150.695000 Tap drift (diff=0.7175mm) — reset probe at 65.999,275.995 is z=1.047500 Tap drift (diff=149.6475mm) — reset probe at 65.999,275.995 is z=1.060000 Tap drift (diff=0.0125mm) — reset probe at 65.999,275.995 is z=1.062500 Tap OK (diff=0.0025mm, stable 2/5) probe at 65.999,275.995 is z=1.065000 Tap OK (diff=0.0025mm, stable 3/5) probe at 65.999,275.995 is z=1.057500 Tap OK (diff=0.0075mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=1.0575 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete! probe at 65.999,275.995 is z=385.900000 probe at 65.999,275.995 is z=385.907500 Tap OK (diff=0.0075mm, stable 2/5) probe at 65.999,275.995 is z=385.930000 Tap drift (diff=0.0225mm) — reset probe at 65.999,275.995 is z=385.935000 Tap OK (diff=0.0050mm, stable 2/5) probe at 65.999,275.995 is z=385.910000 Tap drift (diff=0.0250mm) — reset Tap drift (diff=0.0200mm) — reset probe at 65.999,275.995 is z=385.912500 Tap drift (diff=0.0175mm) — reset probe at 65.999,275.995 is z=385.932500 Tap OK (diff=0.0000mm, stable 4/5) probe at 65.999,275.995 is z=386.817500 Tap drift (diff=0.8850mm) — reset
Screws tilt PASS 08:10:33
probe: at 67.000,271.004 bed will contact at z=0.920000 probe: at 67.000,271.004 bed will contact at z=0.947500 probe: at 67.000,271.004 bed will contact at z=0.940000 probe: at 267.996,271.004 bed will contact at z=0.920000 probe: at 267.996,271.004 bed will contact at z=0.932500 probe: at 267.996,71.995 bed will contact at z=0.775000 probe: at 267.996,71.995 bed will contact at z=0.765000 probe: at 67.000,71.995 bed will contact at z=0.797500 probe: at 67.000,71.995 bed will contact at z=0.840000 probe: at 67.000,71.995 bed will contact at z=0.900000 Probe samples exceed tolerance. Retrying... probe: at 67.000,71.995 bed will contact at z=0.810000 probe: at 67.000,71.995 bed will contact at z=0.877500 probe: at 67.000,71.995 bed will contact at z=0.890000 probe: at 67.000,71.995 bed will contact at z=0.870000 probe: at 67.000,71.995 bed will contact at z=0.867500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=84.0, y=241.0, z=0.94000 front right screw : x=285.0, y=241.0, z=0.92000 : adjust CCW 00:02 rear right screw : x=285.0, y=42.0, z=0.77500 : adjust CCW 00:20 rear left screw : x=84.0, y=42.0, z=0.87000 : adjust CCW 00:08