← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

4C0070000F51353135323934

PASS Grade A Grade B
Model : C235 · Batch : 20260616
Heated bed : 220V · 300W · SSR SSR10DA
QC pad (MAC) : 02813B23751D
Start : 2026-06-30T04:31:14.727211 · End : 2026-06-30T04:43:42.378826 · Duration : 747 s
Received (server) : 2026-06-30T04:43:30
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C235 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=300 ssr=SSR10DA lot=20260616 uid=61C229

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 04:31:14
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C235;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=300;ssr=SSR10DA;lot=20260616;uid=61C229 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=4C0070000F51353135323934
Home X PASS 04:31:36
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.9719 gap=1.0281 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000
Home Y PASS 04:32:04
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 04:32:45
Part fan PASS 04:32:47
Hotend fan PASS 04:32:50
Hotend heat 220°C PASS 04:32:50
Bed heat 60°C PASS 04:32:50
Cutter (feed+cut) PASS 04:36:50
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.9597 gap=1.0403 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7891 gap=1.2109 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 04:37:08
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 100mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 04:39:04
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.9597 gap=1.0403 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7891 gap=1.2109 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 31.003,211.998 is z=95.937500 probe at 31.003,211.998 is z=95.945000 Tap OK (diff=0.0075mm, stable 2/5) probe at 31.003,211.998 is z=95.960000 Tap drift (diff=0.0150mm) — reset probe at 31.003,211.998 is z=95.965000 Tap OK (diff=0.0050mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 31.003,211.998 is z=95.962500 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=95.9650 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete!
Z tap repeatability PASS 04:43:10 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.9875, 255.9000, 255.8700, 255.9000, 255.9000, 255.9000, 255.9000, 255.9025, 255.8975, 255.9000, 255.9000, 255.9025, 255.9000, 255.9000, 255.9000
Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 30.994,211.998 is z=21.200000 probe at 30.994,211.998 is z=8.277500 Tap drift (diff=12.9225mm) — reset probe at 30.994,211.998 is z=0.987500 Tap drift (diff=7.2900mm) — reset Tap OK (diff=0.0000mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=0.9875 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete! probe at 30.994,211.998 is z=255.895000 probe at 30.994,211.998 is z=255.900000 Tap OK (diff=0.0050mm, stable 2/5) VALIDATED: trigger_z=255.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=262.465000 probe at 30.994,211.998 is z=264.982500 Tap drift (diff=2.5175mm) — reset probe at 30.994,211.998 is z=266.570000 Tap drift (diff=1.5875mm) — reset probe at 30.994,211.998 is z=267.692500 Tap rejete (vibration chassis, z=267.6925 > max-z_hop) -> pas de remontee, on poursuit la descente (1) Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10) probe at 30.994,211.998 is z=266.535000 probe at 30.994,211.998 is z=255.862500 Tap drift (diff=10.6725mm) — reset probe at 30.994,211.998 is z=255.867500 probe at 30.994,211.998 is z=255.870000 Tap OK (diff=0.0025mm, stable 3/5) VALIDATED: trigger_z=255.8700 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.897500 Tap OK (diff=0.0025mm, stable 2/5) probe at 30.994,211.998 is z=255.892500 Tap OK (diff=0.0075mm, stable 3/5) probe at 30.994,211.998 is z=255.902500 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=255.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Screws tilt PASS 04:43:42
probe: at 32.495,205.497 bed will contact at z=0.850000 probe: at 32.495,205.497 bed will contact at z=0.872500 probe: at 32.495,205.497 bed will contact at z=0.860000 probe: at 206.996,205.497 bed will contact at z=3.372500 probe: at 206.996,205.497 bed will contact at z=3.385000 probe: at 206.996,205.497 bed will contact at z=3.347500 probe: at 206.996,31.995 bed will contact at z=4.060000 probe: at 206.996,31.995 bed will contact at z=4.040000 probe: at 206.996,31.995 bed will contact at z=4.000000 Probe samples exceed tolerance. Retrying... probe: at 206.996,31.995 bed will contact at z=3.992500 probe: at 206.996,31.995 bed will contact at z=3.965000 probe: at 206.996,31.995 bed will contact at z=4.017500 probe: at 206.996,31.995 bed will contact at z=4.005000 probe: at 206.996,31.995 bed will contact at z=4.020000 probe: at 206.996,31.995 bed will contact at z=4.037500 probe: at 32.495,31.995 bed will contact at z=1.537500 probe: at 32.495,31.995 bed will contact at z=1.547500 probe: at 32.495,31.995 bed will contact at z=1.542500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=49.5, y=175.5, z=0.86000 front right screw : x=224.0, y=175.5, z=3.37250 : adjust CW 05:02 rear right screw : x=224.0, y=2.0, z=4.02000 : adjust CW 06:19 rear left screw : x=49.5, y=2.0, z=1.54250 : adjust CW 01:22

History — 2 reports for this machine

QC dateResultQC pad (MAC)Received (server)
2026-06-30T04:31:14.727211 PASS 4C0070000F51353135323934 2026-06-30T04:43:30
2026-06-30T04:27:08.879217 PARTIAL 4C0070000F51353135323934 2026-06-30T04:25:32