← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

4D0026000F51353135323934

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 220V · 750W · SSR SSR10DA
QC pad (MAC) : 02818836C394
Start : 2026-08-11T06:50:10.197331 · End : 2026-08-11T07:03:12.009362 · Duration : 781 s
Received (server) : 2026-08-11T07:05:51
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=750 ssr=SSR10DA lot=20260618 uid=9221AF

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 06:50:10
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=4D0026000F51353135323934
Home X PASS 06:50:36
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=457.1919 gap=1.8081 (1/4) tap 3: pos=456.8019 gap=2.1981 (2/4) tap 4: pos=457.1919 gap=1.8081 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.3900/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=457.0456 spread=0.3900mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 06:51:15
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.1797 gap=1.8203 (chauffe, ignore) tap 2: pos=-18.7769 gap=1.2231 (1/4) tap 3: pos=-18.7769 gap=1.2231 (2/4) tap 4: pos=-18.7769 gap=1.2231 (3/4) tap 5: pos=-18.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 06:52:06
Part fan PASS 06:52:08
Hotend fan PASS 06:52:10
Hotend heat 220°C PASS 06:52:11
Bed heat 60°C PASS 06:52:11
Cutter (feed+cut) PASS 06:53:39
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=-18.7769 gap=1.2231 (1/4) tap 3: pos=-18.7769 gap=1.2231 (2/4) tap 4: pos=-18.7769 gap=1.2231 (3/4) tap 5: pos=-18.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 06:53:54
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 06:57:28
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=-18.7769 gap=1.2231 (1/4) tap 3: pos=-18.7769 gap=1.2231 (2/4) tap 4: pos=-18.7769 gap=1.2231 (3/4) tap 5: pos=-18.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=415.912500 probe at 49.995,339.999 is z=418.595000 Tap drift (diff=2.6825mm) — reset probe at 49.995,339.999 is z=421.280000 Tap drift (diff=2.6850mm) — reset probe at 49.995,339.999 is z=415.925000 Tap drift (diff=5.3550mm) — reset probe at 49.995,339.999 is z=415.920000 Tap OK (diff=0.0050mm, stable 2/5) Tap drift (diff=2.6750mm) — reset probe at 49.995,339.999 is z=421.277500 probe at 49.995,339.999 is z=418.510000 Tap drift (diff=2.7675mm) — reset probe at 49.995,339.999 is z=421.205000 Tap drift (diff=2.6950mm) — reset probe at 49.995,339.999 is z=415.917500 Tap drift (diff=5.2875mm) — reset probe at 49.995,339.999 is z=418.397500 Tap drift (diff=2.4800mm) — reset probe at 49.995,339.999 is z=421.080000 probe at 49.995,339.999 is z=423.557500
Z tap repeatability PASS 07:02:31 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.1250, 486.1025, 486.1000, 486.1000, 486.1025, 486.1000, 486.1000, 486.1000, 486.1025, 486.1000, 486.1000, 486.1025, 486.1000, 486.1000, 486.1000
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=495.595000 probe at 49.998,339.999 is z=143.490000 Tap drift (diff=352.1050mm) — reset probe at 49.998,339.999 is z=145.342500 Tap drift (diff=1.8525mm) — reset probe at 49.998,339.999 is z=1.125000 Tap drift (diff=144.2175mm) — reset probe at 49.998,339.999 is z=3.617500 Tap drift (diff=2.4925mm) — reset probe at 49.998,339.999 is z=6.310000 Tap drift (diff=2.6925mm) — reset probe at 49.998,339.999 is z=1.130000 Tap drift (diff=5.1800mm) — reset Tap OK (diff=0.0050mm, stable 2/5) probe at 49.998,339.999 is z=1.127500 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=1.1250 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete! probe at 49.998,339.999 is z=495.480000 probe at 49.998,339.999 is z=498.160000 Tap rejete (vibration chassis, z=498.1600 > max-z_hop) -> pas de remontee, on poursuit la descente (1) probe at 49.998,339.999 is z=486.102500 probe at 49.998,339.999 is z=486.090000 Tap drift (diff=0.0125mm) — reset probe at 49.998,339.999 is z=486.100000 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0025mm, stable 4/5) VALIDATED: trigger_z=486.1025 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,339.999 is z=495.475000 probe at 49.998,339.999 is z=498.155000 Tap rejete (vibration chassis, z=498.1550 > max-z_hop) -> pas de remontee, on poursuit la descente (1) Tap OK (diff=0.0000mm, stable 3/5) VALIDATED: trigger_z=486.1000 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,339.999 is z=486.105000 Tap OK (diff=0.0000mm, stable 5/5)
Screws tilt PASS 07:03:12
probe: at 54.997,328.001 bed will contact at z=0.707500 probe: at 54.997,328.001 bed will contact at z=0.712500 probe: at 380.001,328.001 bed will contact at z=0.657500 probe: at 380.001,328.001 bed will contact at z=0.672500 probe: at 380.001,328.001 bed will contact at z=0.670000 probe: at 380.001,101.996 bed will contact at z=0.747500 probe: at 380.001,101.996 bed will contact at z=0.762500 probe: at 54.997,101.996 bed will contact at z=0.782500 probe: at 217.505,214.498 bed will contact at z=0.757500 probe: at 217.505,214.498 bed will contact at z=0.770000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=0.70750 front right screw : x=397.0, y=298.0, z=0.67000 : adjust CCW 00:04 rear right screw : x=397.0, y=72.0, z=0.74750 : adjust CW 00:05 rear left screw : x=72.0, y=72.0, z=0.78250 : adjust CW 00:09 middle : x=234.5, y=184.5, z=0.75750 : adjust CW 00:06