← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

4D0047000D51353234323830

PASS Grade A Grade B
Model : C235 · Batch : 20260616
Heated bed : 220V · 300W · SSR SSR10DA
QC pad (MAC) : 02813C788EB7
Start : 2026-06-27T03:13:18.225763 · End : 2026-06-27T03:24:29.473148 · Duration : 671 s
Received (server) : 2026-06-27T04:02:25
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C235 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=300 ssr=SSR10DA lot=20260616 uid=61C229

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 03:13:18
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C235;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=300;ssr=SSR10DA;lot=20260616;uid=61C229 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=4D0047000D51353234323830
Home X PASS 03:13:41
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000
Home Y PASS 03:14:16
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.6184 gap=1.3816 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 03:14:25
Part fan PASS 03:14:28
Hotend fan PASS 03:14:32
Hotend heat 220°C PASS 03:14:38
Bed heat 60°C PASS 03:14:51
Cutter (feed+cut) PASS 03:16:13
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 03:16:24
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 50mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 03:19:25
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 31.003,211.998 is z=263.337500 probe at 31.003,211.998 is z=252.412500 Tap drift (diff=10.9250mm) — reset probe at 31.003,211.998 is z=254.900000 Tap drift (diff=2.4875mm) — reset Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10) probe at 31.003,211.998 is z=245.060000 Tap drift (diff=9.8400mm) — reset probe at 31.003,211.998 is z=243.012500 Tap drift (diff=2.0475mm) — reset probe at 31.003,211.998 is z=217.780000 Tap drift (diff=25.2325mm) — reset probe at 31.003,211.998 is z=200.655000 Tap drift (diff=17.1250mm) — reset probe at 31.003,211.998 is z=198.147500 Tap drift (diff=2.5075mm) — reset probe at 31.003,211.998 is z=198.607500 Tap drift (diff=0.4600mm) — reset probe at 31.003,211.998 is z=197.697500 Tap drift (diff=0.9100mm) — reset probe at 31.003,211.998 is z=162.187500
Z tap repeatability PASS 03:23:56 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.0850, 255.9000, 255.8925, 255.8900, 255.9000, 255.9125, 255.9075, 255.8725, 255.9375, 255.9000, 255.9000, 255.9025, 255.9250, 255.8975, 255.9075
Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 30.994,211.998 is z=265.125000 probe at 30.994,211.998 is z=264.367500 Tap drift (diff=0.7575mm) — reset probe at 30.994,211.998 is z=252.085000 Tap drift (diff=12.2825mm) — reset probe at 30.994,211.998 is z=217.642500 Tap drift (diff=34.4425mm) — reset probe at 30.994,211.998 is z=1.020000 Tap drift (diff=216.6225mm) — reset probe at 30.994,211.998 is z=1.052500 Tap drift (diff=0.0325mm) — reset probe at 30.994,211.998 is z=1.090000 Tap drift (diff=0.0375mm) — reset probe at 30.994,211.998 is z=1.092500 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0025mm, stable 4/5) probe at 30.994,211.998 is z=1.085000 Tap OK (diff=0.0050mm, stable 5/5) VALIDATED: trigger_z=1.0850 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete! probe at 30.994,211.998 is z=255.862500 probe at 30.994,211.998 is z=255.910000 Tap drift (diff=0.0475mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 30.994,211.998 is z=255.905000 Tap OK (diff=0.0050mm, stable 3/5) probe at 30.994,211.998 is z=255.902500 probe at 30.994,211.998 is z=255.900000 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=255.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.867500 probe at 30.994,211.998 is z=255.912500 Tap drift (diff=0.0450mm) — reset Tap OK (diff=0.0075mm, stable 2/5) Tap OK (diff=0.0025mm, stable 3/5) probe at 30.994,211.998 is z=255.897500
Screws tilt PASS 03:24:29
probe: at 32.495,205.497 bed will contact at z=1.277500 probe: at 32.495,205.497 bed will contact at z=1.357500 Probe samples exceed tolerance. Retrying... probe: at 32.495,205.497 bed will contact at z=1.352500 probe: at 32.495,205.497 bed will contact at z=1.355000 probe: at 206.996,205.497 bed will contact at z=3.495000 probe: at 206.996,205.497 bed will contact at z=3.600000 probe: at 206.996,205.497 bed will contact at z=3.595000 probe: at 206.996,205.497 bed will contact at z=3.612500 probe: at 206.996,31.995 bed will contact at z=2.677500 probe: at 206.996,31.995 bed will contact at z=2.792500 probe: at 206.996,31.995 bed will contact at z=2.782500 probe: at 206.996,31.995 bed will contact at z=2.805000 probe: at 32.495,31.995 bed will contact at z=0.635000 probe: at 32.495,31.995 bed will contact at z=0.655000 probe: at 32.495,31.995 bed will contact at z=0.640000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=49.5, y=175.5, z=1.35250 front right screw : x=224.0, y=175.5, z=3.61250 : adjust CW 04:31 rear right screw : x=224.0, y=2.0, z=2.79250 : adjust CW 02:53 rear left screw : x=49.5, y=2.0, z=0.64000 : adjust CCW 01:25