← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

4E0043000D51353234323830

PASS Grade A Grade B
Model : C235 · Batch : 20260618
Heated bed : 110V · 300W · SSR SSR10DA
QC pad (MAC) : 02813B23751D
Start : 2026-07-09T06:28:40.306526 · End : 2026-07-09T06:39:20.717699 · Duration : 640 s
Received (server) : 2026-07-09T07:08:36
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C235 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=110V bedw=300 ssr=SSR10DA lot=20260618 uid=BBA413

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 06:28:40
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C235;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=300;ssr=SSR10DA;lot=20260618;uid=BBA413 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=4E0043000D51353234323830
Home X PASS 06:29:05
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.5819 gap=1.4181 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000
Home Y PASS 06:29:35
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.5819 gap=1.4181 (chauffe, ignore) tap 2: pos=-30.5819 gap=1.4181 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-30.1919 gap=1.8081 (3/4) tap 5: pos=-30.5819 gap=1.4181 fenetre=0.5850/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.3381 spread=0.5850mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 06:30:08
Part fan PASS 06:30:11
Hotend fan PASS 06:30:14
Hotend heat 220°C PASS 06:30:14
Bed heat 60°C PASS 06:30:17
Cutter (feed+cut) PASS 06:31:46
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.6062 gap=1.3938 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 06:32:01
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 06:34:52
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 31.003,211.998 is z=232.895000 Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10) probe at 31.003,211.998 is z=193.535000 Tap drift (diff=39.3600mm) — reset probe at 31.003,211.998 is z=181.950000 Tap drift (diff=11.5850mm) — reset probe at 31.003,211.998 is z=182.455000 Tap drift (diff=0.5050mm) — reset probe at 31.003,211.998 is z=153.140000 Tap drift (diff=29.3150mm) — reset probe at 31.003,211.998 is z=153.147500 Tap OK (diff=0.0075mm, stable 2/5) probe at 31.003,211.998 is z=153.167500 Tap drift (diff=0.0200mm) — reset probe at 31.003,211.998 is z=153.170000 Tap OK (diff=0.0025mm, stable 2/5) probe at 31.003,211.998 is z=153.172500 Tap OK (diff=0.0025mm, stable 3/5) probe at 31.003,211.998 is z=153.175000 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5)
Z tap repeatability PASS 06:38:46 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.0650, 255.9025, 255.9025, 255.9000, 255.9000, 255.9000, 255.9025, 255.8975, 255.9000, 255.9000, 255.9000, 255.9000, 255.9000, 255.9000, 255.9000
Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 30.994,211.998 is z=1.055000 probe at 30.994,211.998 is z=1.062500 Tap OK (diff=0.0075mm, stable 2/5) probe at 30.994,211.998 is z=1.065000 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=1.0650 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete! probe at 30.994,211.998 is z=255.897500 Tap OK (diff=0.0000mm, stable 2/5) probe at 30.994,211.998 is z=255.900000 Tap OK (diff=0.0025mm, stable 4/5) probe at 30.994,211.998 is z=255.902500 Tap OK (diff=0.0050mm, stable 5/5) VALIDATED: trigger_z=255.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0025mm, stable 5/5) probe at 30.994,211.998 is z=255.895000 VALIDATED: trigger_z=255.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) VALIDATED: trigger_z=255.8975 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Tap OK (diff=0.0050mm, stable 2/5) probe at 30.994,211.998 is z=255.905000 Tap OK (diff=0.0050mm, stable 4/5)
Screws tilt PASS 06:39:20
probe: at 32.495,205.497 bed will contact at z=1.857500 probe: at 32.495,205.497 bed will contact at z=1.925000 Probe samples exceed tolerance. Retrying... probe: at 32.495,205.497 bed will contact at z=1.822500 probe: at 32.495,205.497 bed will contact at z=1.867500 probe: at 32.495,205.497 bed will contact at z=1.882500 probe: at 32.495,205.497 bed will contact at z=1.837500 probe: at 32.495,205.497 bed will contact at z=1.865000 probe: at 32.495,205.497 bed will contact at z=1.855000 probe: at 206.996,205.497 bed will contact at z=1.802500 probe: at 206.996,205.497 bed will contact at z=1.807500 probe: at 206.996,31.995 bed will contact at z=1.675000 probe: at 206.996,31.995 bed will contact at z=1.680000 probe: at 206.996,31.995 bed will contact at z=1.685000 probe: at 32.495,31.995 bed will contact at z=1.805000 probe: at 32.495,31.995 bed will contact at z=1.865000 probe: at 32.495,31.995 bed will contact at z=1.875000 probe: at 32.495,31.995 bed will contact at z=1.880000 probe: at 32.495,31.995 bed will contact at z=1.910000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=49.5, y=175.5, z=1.85500 front right screw : x=224.0, y=175.5, z=1.80750 : adjust CCW 00:06 rear right screw : x=224.0, y=2.0, z=1.68000 : adjust CCW 00:21 rear left screw : x=49.5, y=2.0, z=1.88000 : adjust CW 00:03