SmartPi 1
SmartPi 2

4E004D000F51353135323934

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 220V · 750W · SSR SSR10DA
QC pad (MAC) : 0281D225B2A9
Start : 2026-08-12T05:45:04.850876 · End : 2026-08-12T05:57:18.380272 · Duration : 733 s
Received (server) : 2026-08-12T06:26:06
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=750 ssr=SSR10DA lot=20260618 uid=9221AF

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 05:45:05
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=4E004D000F51353135323934
Home X PASS 05:45:30
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.3747 gap=1.6253 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 05:46:04
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=-18.7769 gap=1.2231 (1/4) tap 3: pos=-18.7769 gap=1.2231 (2/4) tap 4: pos=-18.7769 gap=1.2231 (3/4) tap 5: pos=-18.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 05:46:17
Part fan PASS 05:46:20
Hotend fan PASS 05:46:22
Hotend heat 220°C PASS 05:46:27
Bed heat 60°C PASS 05:46:40
Cutter (feed+cut) PASS 05:48:08
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.3747 gap=1.6253 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=-18.7769 gap=1.2231 (1/4) tap 3: pos=-18.7769 gap=1.2231 (2/4) tap 4: pos=-18.7769 gap=1.2231 (3/4) tap 5: pos=-18.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 05:48:23
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 05:51:42
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.3869 gap=1.6131 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=-18.7769 gap=1.2231 (1/4) tap 3: pos=-18.7769 gap=1.2231 (2/4) tap 4: pos=-18.7769 gap=1.2231 (3/4) tap 5: pos=-18.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=462.732500 probe at 49.995,339.999 is z=455.645000 Tap drift (diff=7.0875mm) — reset probe at 49.995,339.999 is z=449.125000 Tap drift (diff=6.5200mm) — reset probe at 49.995,339.999 is z=429.240000 Tap drift (diff=19.8850mm) — reset probe at 49.995,339.999 is z=418.450000 Tap drift (diff=10.7900mm) — reset probe at 49.995,339.999 is z=421.425000 Tap drift (diff=2.9750mm) — reset probe at 49.995,339.999 is z=412.570000 Tap drift (diff=8.8550mm) — reset probe at 49.995,339.999 is z=412.572500 Tap OK (diff=0.0025mm, stable 2/5) probe at 49.995,339.999 is z=412.882500 Tap drift (diff=0.3100mm) — reset probe at 49.995,339.999 is z=412.575000 Tap drift (diff=0.3075mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 49.995,339.999 is z=412.577500
Z tap repeatability PASS 05:56:38 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.0950, 486.1000, 486.1050, 486.1025, 486.1000, 486.1025, 486.1075, 486.1025, 486.1000, 486.0975, 486.1025, 486.0975, 486.1075, 486.0975, 486.1000
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=482.005000 probe at 49.998,339.999 is z=474.250000 Tap drift (diff=7.7550mm) — reset probe at 49.998,339.999 is z=448.202500 Tap drift (diff=26.0475mm) — reset probe at 49.998,339.999 is z=436.702500 Tap drift (diff=11.5000mm) — reset probe at 49.998,339.999 is z=439.657500 Tap drift (diff=2.9550mm) — reset probe at 49.998,339.999 is z=442.132500 Tap drift (diff=2.4750mm) — reset probe at 49.998,339.999 is z=1.087500 Tap drift (diff=441.0450mm) — reset probe at 49.998,339.999 is z=1.090000 Tap OK (diff=0.0025mm, stable 2/5) probe at 49.998,339.999 is z=1.092500 Tap OK (diff=0.0025mm, stable 3/5) probe at 49.998,339.999 is z=1.095000 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=1.0950 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete! probe at 49.998,339.999 is z=486.100000 probe at 49.998,339.999 is z=486.102500 Tap OK (diff=0.0000mm, stable 3/5) VALIDATED: trigger_z=486.1000 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,339.999 is z=486.095000 Tap OK (diff=0.0075mm, stable 2/5) probe at 49.998,339.999 is z=486.107500 Tap OK (diff=0.0050mm, stable 3/5) probe at 49.998,339.999 is z=486.105000 VALIDATED: trigger_z=486.1050 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Tap OK (diff=0.0050mm, stable 2/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=486.1025 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,339.999 is z=486.097500
Screws tilt PASS 05:57:18
probe: at 54.997,328.001 bed will contact at z=1.070000 probe: at 54.997,328.001 bed will contact at z=1.060000 probe: at 54.997,328.001 bed will contact at z=1.085000 probe: at 380.001,328.001 bed will contact at z=0.910000 probe: at 380.001,328.001 bed will contact at z=0.887500 probe: at 380.001,328.001 bed will contact at z=0.902500 probe: at 380.001,101.996 bed will contact at z=1.022500 probe: at 380.001,101.996 bed will contact at z=1.012500 probe: at 380.001,101.996 bed will contact at z=1.055000 probe: at 54.997,101.996 bed will contact at z=0.995000 probe: at 54.997,101.996 bed will contact at z=1.007500 probe: at 54.997,101.996 bed will contact at z=1.005000 probe: at 217.505,214.498 bed will contact at z=1.092500 probe: at 217.505,214.498 bed will contact at z=1.085000 probe: at 217.505,214.498 bed will contact at z=1.090000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=1.07000 front right screw : x=397.0, y=298.0, z=0.90250 : adjust CCW 00:20 rear right screw : x=397.0, y=72.0, z=1.02250 : adjust CCW 00:06 rear left screw : x=72.0, y=72.0, z=1.00500 : adjust CCW 00:08 middle : x=234.5, y=184.5, z=1.09000 : adjust CW 00:02