← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

4E0055000F51353135323934

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 220V · 750W · SSR SSR10DA
QC pad (MAC) : 0281D225B2A9
Start : 2026-08-14T03:13:24.823964 · End : 2026-08-14T03:26:04.210422 · Duration : 759 s
Received (server) : 2026-08-14T04:39:17
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=750 ssr=SSR10DA lot=20260618 uid=9221AF

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 03:13:24
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=4E0055000F51353135323934
Home X PASS 03:13:50
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 03:14:27
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-18.7769 gap=1.2231 (1/4) tap 3: pos=-18.7769 gap=1.2231 (2/4) tap 4: pos=-18.7769 gap=1.2231 (3/4) tap 5: pos=-18.7647 gap=1.2353 fenetre=0.0122/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.7738 spread=0.0122mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 03:15:34
Part fan PASS 03:15:40
Hotend fan PASS 03:15:42
Hotend heat 220°C PASS 03:15:43
Bed heat 60°C PASS 03:15:43
Cutter (feed+cut) PASS 03:17:25
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=457.1797 gap=1.8203 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.1828/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=457.0426 spread=0.1828mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-18.7769 gap=1.2231 (1/4) tap 3: pos=-18.7647 gap=1.2353 (2/4) tap 4: pos=-18.5941 gap=1.4059 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.7800/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-18.5331 spread=0.7800mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 03:17:39
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 03:20:50
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=457.7769 gap=1.2231 (1/4) tap 3: pos=457.5941 gap=1.4059 (2/4) tap 4: pos=457.1797 gap=1.8203 (3/4) tap 5: pos=457.7769 gap=1.2231 fenetre=0.5972/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=457.5819 spread=0.5972mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.1797 gap=1.8203 (chauffe, ignore) tap 2: pos=-18.7769 gap=1.2231 (1/4) tap 3: pos=-18.7769 gap=1.2231 (2/4) tap 4: pos=-18.7769 gap=1.2231 (3/4) tap 5: pos=-18.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=403.225000 probe at 49.995,339.999 is z=403.242500 Tap drift (diff=0.0175mm) — reset probe at 49.995,339.999 is z=403.240000 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=403.2425 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete!
Z tap repeatability PASS 03:25:26 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.1300, 486.1025, 486.0925, 486.1025, 486.1000, 486.1025, 486.1050, 486.1000, 486.1000, 486.0975, 486.1025, 486.0975, 486.1025, 486.1000, 486.1025
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=495.615000 probe at 49.998,339.999 is z=1.120000 Tap drift (diff=494.4950mm) — reset probe at 49.998,339.999 is z=1.122500 Tap OK (diff=0.0025mm, stable 2/5) probe at 49.998,339.999 is z=1.125000 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) probe at 49.998,339.999 is z=1.130000 Tap OK (diff=0.0050mm, stable 5/5) VALIDATED: trigger_z=1.1300 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete! probe at 49.998,339.999 is z=486.100000 probe at 49.998,339.999 is z=486.102500 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=486.1025 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,339.999 is z=486.097500 probe at 49.998,339.999 is z=486.092500 Tap OK (diff=0.0050mm, stable 3/5) probe at 49.998,339.999 is z=486.095000 Tap OK (diff=0.0025mm, stable 4/5) VALIDATED: trigger_z=486.0925 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Tap OK (diff=0.0000mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=486.1000 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,339.999 is z=486.105000 Tap OK (diff=0.0050mm, stable 4/5) VALIDATED: trigger_z=486.1050 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,339.999 is z=495.125000 Tap drift (diff=9.0200mm) — reset Tap OK (diff=0.0100mm, stable 4/5) VALIDATED: trigger_z=486.0975 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,339.999 is z=486.107500 Tap OK (diff=0.0100mm, stable 3/5) Tap OK (diff=0.0050mm, stable 2/5) probe at 49.998,339.999 is z=486.112500
Screws tilt PASS 03:26:04
probe: at 54.997,328.001 bed will contact at z=2.410000 probe: at 54.997,328.001 bed will contact at z=2.415000 probe: at 54.997,328.001 bed will contact at z=2.412500 probe: at 380.001,328.001 bed will contact at z=2.362500 probe: at 380.001,328.001 bed will contact at z=2.367500 probe: at 380.001,101.996 bed will contact at z=2.327500 probe: at 380.001,101.996 bed will contact at z=2.342500 probe: at 380.001,101.996 bed will contact at z=2.340000 probe: at 54.997,101.996 bed will contact at z=2.420000 probe: at 54.997,101.996 bed will contact at z=2.415000 probe: at 217.505,214.498 bed will contact at z=2.415000 probe: at 217.505,214.498 bed will contact at z=2.412500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=2.41250 front right screw : x=397.0, y=298.0, z=2.36250 : adjust CCW 00:06 rear right screw : x=397.0, y=72.0, z=2.34000 : adjust CCW 00:09 rear left screw : x=72.0, y=72.0, z=2.42000 : adjust CW 00:01 middle : x=234.5, y=184.5, z=2.41500 : adjust CW 00:00