← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

4E0061000F51353135323934

PASS Grade A Grade B
Model : C235 · Batch : 20260616
Heated bed : 220V · 300W · SSR SSR10DA
QC pad (MAC) : 02817A147AB3
Start : 2026-07-01T07:15:39.300621 · End : 2026-07-01T07:26:06.461063 · Duration : 627 s
Received (server) : 2026-07-01T08:55:32
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C235 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=300 ssr=SSR10DA lot=20260616 uid=61C229

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 07:15:39
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C235;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=300;ssr=SSR10DA;lot=20260616;uid=61C229 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=4E0061000F51353135323934
Home X PASS 07:16:05
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000
Home Y PASS 07:16:34
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7891 gap=1.2109 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 07:16:41
Part fan PASS 07:16:43
Hotend fan PASS 07:16:45
Hotend heat 220°C PASS 07:16:45
Bed heat 60°C PASS 07:16:45
Cutter (feed+cut) PASS 07:18:08
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 07:18:23
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 07:21:10
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 31.003,211.998 is z=265.380000 probe at 31.003,211.998 is z=267.832500 Tap rejete (vibration chassis, z=267.8325 > max-z_hop) -> pas de remontee, on poursuit la descente (1) probe at 31.003,211.998 is z=115.972500 probe at 31.003,211.998 is z=115.967500 Tap OK (diff=0.0050mm, stable 2/5) probe at 31.003,211.998 is z=115.970000 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=115.9725 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete!
Z tap repeatability PASS 07:25:27 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.8650, 255.7500, 255.9000, 255.9025, 255.8975, 255.9025, 255.8975, 255.9050, 255.9000, 255.8975, 255.9025, 255.8950, 255.9000, 255.9000, 255.9025
Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 30.994,211.998 is z=0.867500 probe at 30.994,211.998 is z=0.872500 Tap OK (diff=0.0050mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 30.994,211.998 is z=0.885000 Tap drift (diff=0.0125mm) — reset probe at 30.994,211.998 is z=1.945000 Tap drift (diff=1.0600mm) — reset probe at 30.994,211.998 is z=4.182500 Tap drift (diff=2.2375mm) — reset probe at 30.994,211.998 is z=6.297500 Tap drift (diff=2.1150mm) — reset probe at 30.994,211.998 is z=0.875000 Tap drift (diff=5.4225mm) — reset probe at 30.994,211.998 is z=2.825000 Tap drift (diff=1.9500mm) — reset probe at 30.994,211.998 is z=4.860000 Tap drift (diff=2.0350mm) — reset probe at 30.994,211.998 is z=7.147500 Tap drift (diff=2.2875mm) — reset Tap drift (diff=6.2800mm) — reset probe at 30.994,211.998 is z=0.870000 Tap OK (diff=0.0025mm, stable 4/5) probe at 30.994,211.998 is z=1.822500 Tap drift (diff=0.9525mm) — reset probe at 30.994,211.998 is z=0.865000 Tap drift (diff=0.9575mm) — reset probe at 30.994,211.998 is z=0.862500 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=0.8650 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete! probe at 30.994,211.998 is z=255.752500 probe at 30.994,211.998 is z=255.755000 probe at 30.994,211.998 is z=255.750000 VALIDATED: trigger_z=255.7500 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Screws tilt PASS 07:26:06
probe: at 32.495,205.497 bed will contact at z=1.390000 probe: at 32.495,205.497 bed will contact at z=1.622500 Probe samples exceed tolerance. Retrying... probe: at 32.495,205.497 bed will contact at z=1.617500 probe: at 32.495,205.497 bed will contact at z=1.615000 probe: at 206.996,205.497 bed will contact at z=4.260000 probe: at 206.996,205.497 bed will contact at z=4.557500 probe: at 206.996,205.497 bed will contact at z=4.465000 probe: at 206.996,205.497 bed will contact at z=4.527500 probe: at 206.996,205.497 bed will contact at z=4.520000 probe: at 206.996,205.497 bed will contact at z=4.577500 probe: at 206.996,205.497 bed will contact at z=4.507500 probe: at 206.996,205.497 bed will contact at z=4.552500 probe: at 206.996,31.995 bed will contact at z=3.205000 probe: at 206.996,31.995 bed will contact at z=3.470000 probe: at 206.996,31.995 bed will contact at z=3.480000 probe: at 206.996,31.995 bed will contact at z=3.435000 probe: at 206.996,31.995 bed will contact at z=3.447500 probe: at 32.495,31.995 bed will contact at z=1.185000 probe: at 32.495,31.995 bed will contact at z=1.417500 probe: at 32.495,31.995 bed will contact at z=1.412500 probe: at 32.495,31.995 bed will contact at z=1.400000 probe: at 32.495,31.995 bed will contact at z=1.410000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=49.5, y=175.5, z=1.61750 front right screw : x=224.0, y=175.5, z=4.50750 : adjust CW 05:47 rear right screw : x=224.0, y=2.0, z=3.44750 : adjust CW 03:40 rear left screw : x=49.5, y=2.0, z=1.41000 : adjust CCW 00:25

History — 9 reports for this machine

QC dateResultQC pad (MAC)Received (server)
2026-07-01T07:15:39.300621 PASS 4E0061000F51353135323934 2026-07-01T08:55:32
2026-07-01T07:10:05.516575 PARTIAL 4E0061000F51353135323934 2026-07-01T07:09:50
2026-07-01T05:35:33.383602 FAIL 4E0061000F51353135323934 2026-07-01T05:47:41
2026-06-30T05:15:21.264704 FAIL 4E0061000F51353135323934 2026-06-30T05:20:07
2026-06-30T05:12:28.951514 FAIL 4E0061000F51353135323934 2026-06-30T05:09:59
2026-06-30T05:01:51.909639 FAIL 4E0061000F51353135323934 2026-06-30T05:06:02
2026-06-29T00:41:47.412482 FAIL 4E0061000F51353135323934 2026-06-29T00:51:44
2026-06-27T04:36:46.112159 FAIL 4E0061000F51353135323934 2026-06-27T04:38:38
2026-06-27T04:24:20.055799 FAIL 4E0061000F51353135323934 2026-06-27T04:25:59