← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

500055000F51353135323934

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 220V · 750W · SSR SSR10DA
QC pad (MAC) : 028103694A6F
Start : 2026-08-11T14:13:12.320125 · End : 2026-08-11T14:25:59.837285 · Duration : 767 s
Received (server) : 2026-08-11T06:28:45
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=750 ssr=SSR10DA lot=20260618 uid=9221AF

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 14:13:12
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=500055000F51353135323934
Home X PASS 14:13:38
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=467.5819 gap=1.4181 (chauffe, ignore) tap 2: pos=466.9969 gap=2.0031 (1/4) tap 3: pos=466.9969 gap=2.0031 (2/4) tap 4: pos=466.9969 gap=2.0031 (3/4) tap 5: pos=466.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=466.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=467.0000
Home Y PASS 14:14:15
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-21.6062 gap=1.3938 (chauffe, ignore) tap 2: pos=-21.7647 gap=1.2353 (1/4) tap 3: pos=-21.7769 gap=1.2231 (2/4) tap 4: pos=-21.7769 gap=1.2231 (3/4) tap 5: pos=-21.7769 gap=1.2231 fenetre=0.0122/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-21.7738 spread=0.0122mm (tol=0.0500). Zero pose en butee=-21.0000
Motherboard fan PASS 14:14:21
Part fan PASS 14:14:23
Hotend fan PASS 14:14:25
Hotend heat 220°C PASS 14:14:32
Bed heat 60°C PASS 14:14:59
Cutter (feed+cut) PASS 14:16:31
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=467.5819 gap=1.4181 (chauffe, ignore) tap 2: pos=466.9847 gap=2.0153 (1/4) tap 3: pos=466.9969 gap=2.0031 (2/4) tap 4: pos=467.0091 gap=1.9909 (3/4) tap 5: pos=466.9969 gap=2.0031 fenetre=0.0244/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=466.9969 spread=0.0244mm (tol=0.0500). Zero pose en butee=467.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-21.5819 gap=1.4181 (chauffe, ignore) tap 2: pos=-21.7769 gap=1.2231 (1/4) tap 3: pos=-21.7769 gap=1.2231 (2/4) tap 4: pos=-21.7769 gap=1.2231 (3/4) tap 5: pos=-21.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-21.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-21.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 14:16:50
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 100mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 14:20:17
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=467.5819 gap=1.4181 (chauffe, ignore) tap 2: pos=466.8141 gap=2.1859 (1/4) tap 3: pos=466.9969 gap=2.0031 (2/4) tap 4: pos=466.9969 gap=2.0031 (3/4) tap 5: pos=467.1919 gap=1.8081 fenetre=0.3778/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=466.9999 spread=0.3778mm (tol=0.0500). Zero pose en butee=467.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-21.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=-21.7769 gap=1.2231 (1/4) tap 3: pos=-21.7769 gap=1.2231 (2/4) tap 4: pos=-21.7769 gap=1.2231 (3/4) tap 5: pos=-21.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-21.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-21.0000 Moving to tap point X=56.0 Y=334.0... Probing with pressure switch... probe at 55.998,334.001 is z=474.175000 probe at 55.998,334.001 is z=463.512500 Tap drift (diff=10.6625mm) — reset probe at 55.998,334.001 is z=456.205000 Tap drift (diff=7.3075mm) — reset probe at 55.998,334.001 is z=448.502500 Tap drift (diff=7.7025mm) — reset probe at 55.998,334.001 is z=438.545000 Tap drift (diff=9.9575mm) — reset probe at 55.998,334.001 is z=433.472500 Tap drift (diff=5.0725mm) — reset probe at 55.998,334.001 is z=435.345000 Tap drift (diff=1.8725mm) — reset probe at 55.998,334.001 is z=412.722500 Tap drift (diff=22.6225mm) — reset probe at 55.998,334.001 is z=412.712500 Tap OK (diff=0.0100mm, stable 2/5) probe at 55.998,334.001 is z=412.715000 Tap OK (diff=0.0025mm, stable 3/5) probe at 55.998,334.001 is z=412.717500 Tap OK (diff=0.0025mm, stable 4/5)
Z tap repeatability PASS 14:25:26 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.1300, 486.1000, 486.1050, 486.1000, 486.1025, 486.1000, 486.1000, 486.1025, 486.1000, 486.1000, 486.1025, 486.0975, 486.1025, 486.1000, 486.0975
Moving to tap point X=56.0 Y=334.0... Probing with pressure switch... probe at 56.001,334.001 is z=474.275000 probe at 56.001,334.001 is z=375.527500 Tap drift (diff=98.7475mm) — reset probe at 56.001,334.001 is z=364.680000 Tap drift (diff=10.8475mm) — reset probe at 56.001,334.001 is z=302.782500 Tap drift (diff=61.8975mm) — reset probe at 56.001,334.001 is z=305.777500 Tap drift (diff=2.9950mm) — reset probe at 56.001,334.001 is z=307.882500 Tap drift (diff=2.1050mm) — reset probe at 56.001,334.001 is z=1.120000 Tap drift (diff=306.7625mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 56.001,334.001 is z=1.117500 Tap OK (diff=0.0025mm, stable 3/5) probe at 56.001,334.001 is z=1.127500 Tap drift (diff=0.0100mm) — reset probe at 56.001,334.001 is z=1.130000 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=1.1300 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (56.0, 334.0) ~ point de tap (56.0, 334.0) Z calibration complete! probe at 56.001,334.001 is z=486.097500 probe at 56.001,334.001 is z=486.102500 Tap OK (diff=0.0050mm, stable 3/5) probe at 56.001,334.001 is z=486.105000 Tap OK (diff=0.0025mm, stable 4/5) probe at 56.001,334.001 is z=486.100000 Tap OK (diff=0.0050mm, stable 5/5) VALIDATED: trigger_z=486.1000 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Tap OK (diff=0.0000mm, stable 3/5) VALIDATED: trigger_z=486.1050 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Tap OK (diff=0.0050mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=486.1025 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Screws tilt PASS 14:25:59
probe: at 56.003,334.994 bed will contact at z=2.545000 probe: at 56.003,334.994 bed will contact at z=2.555000 probe: at 56.003,334.994 bed will contact at z=2.552500 probe: at 388.002,334.994 bed will contact at z=2.580000 probe: at 388.002,334.994 bed will contact at z=2.590000 probe: at 388.002,334.994 bed will contact at z=2.577500 probe: at 388.002,110.001 bed will contact at z=2.607500 probe: at 388.002,110.001 bed will contact at z=2.595000 probe: at 388.002,110.001 bed will contact at z=2.610000 probe: at 56.003,110.001 bed will contact at z=2.540000 probe: at 56.003,110.001 bed will contact at z=2.562500 probe: at 221.996,222.004 bed will contact at z=2.582500 probe: at 221.996,222.004 bed will contact at z=2.587500 probe: at 221.996,222.004 bed will contact at z=2.597500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=73.0, y=305.0, z=2.55250 front right screw : x=405.0, y=305.0, z=2.58000 : adjust CW 00:03 rear right screw : x=405.0, y=80.0, z=2.60750 : adjust CW 00:07 rear left screw : x=73.0, y=80.0, z=2.54000 : adjust CCW 00:01 rear middle screw : x=239.0, y=192.0, z=2.58750 : adjust CW 00:04