| Test | Result | Time | Details / log |
|---|---|---|---|
| MCU + firmware | PASS | 04:46:13 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=520043000D51353234323830
|
| Home X | PASS | 04:46:39 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
|
| Home Y | PASS | 04:47:14 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-18.7769 gap=1.2231 (chauffe, ignore)
tap 2: pos=-17.9969 gap=2.0031 (1/4)
tap 3: pos=-17.9969 gap=2.0031 (2/4)
tap 4: pos=-17.9969 gap=2.0031 (3/4)
tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
|
| Motherboard fan | PASS | 04:47:18 | |
| Part fan | PASS | 04:47:20 | |
| Hotend fan | PASS | 04:47:23 | |
| Hotend heat 220°C | PASS | 04:47:33 | |
| Bed heat 60°C | PASS | 04:47:55 | |
| Cutter (feed+cut) | PASS | 04:49:45 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-18.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=-17.9969 gap=2.0031 (1/4)
tap 3: pos=-17.9969 gap=2.0031 (2/4)
tap 4: pos=-17.9969 gap=2.0031 (3/4)
tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Extruder 'extruder1' now syncing with ''
Extruder 'extruder0' now syncing with 'extruder'
QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte)
QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120
Extruder 'extruder0' now syncing with ''
|
| YMS-2 feed to head | PASS | 04:50:00 |
Extruder 'extruder0' now syncing with ''
Extruder 'extruder1' now syncing with ''
Extruder 'extruder1' now syncing with 'extruder'
QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte)
QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
|
| Z tap home + Zmax | PASS | 04:52:35 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-17.9847 gap=2.0153 (chauffe, ignore)
tap 2: pos=-17.9969 gap=2.0031 (1/4)
tap 3: pos=-17.9969 gap=2.0031 (2/4)
tap 4: pos=-17.9969 gap=2.0031 (3/4)
tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.995,339.999 is z=414.445000
probe at 49.995,339.999 is z=414.435000
Tap OK (diff=0.0100mm, stable 2/5)
probe at 49.995,339.999 is z=414.432500
Tap OK (diff=0.0025mm, stable 3/5)
probe at 49.995,339.999 is z=414.427500
Tap OK (diff=0.0050mm, stable 4/5)
probe at 49.995,339.999 is z=414.450000
Tap drift (diff=0.0225mm) — reset
Tap OK (diff=0.0000mm, stable 2/5)
Tap OK (diff=0.0000mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 4/5)
probe at 49.995,339.999 is z=414.455000
Tap OK (diff=0.0050mm, stable 5/5)
VALIDATED: trigger_z=414.4550 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z calibration complete!
|
| Z tap repeatability | PASS | 04:57:09 |
OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.1175, 486.1050, 486.1075, 486.1025, 486.1025, 486.1025, 486.1025, 486.1025, 486.0975, 486.1025, 486.1000, 486.1025, 486.0975, 486.1000, 486.1025
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.998,339.999 is z=21.380000
probe at 49.998,339.999 is z=1.112500
Tap drift (diff=20.2675mm) — reset
probe at 49.998,339.999 is z=1.105000
Tap OK (diff=0.0075mm, stable 2/5)
Tap OK (diff=0.0075mm, stable 3/5)
probe at 49.998,339.999 is z=1.117500
Tap OK (diff=0.0050mm, stable 4/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=1.1175 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z calibration complete!
probe at 49.998,339.999 is z=486.095000
probe at 49.998,339.999 is z=486.105000
Tap drift (diff=0.0100mm) — reset
probe at 49.998,339.999 is z=486.092500
Tap drift (diff=0.0125mm) — reset
probe at 49.998,339.999 is z=486.102500
Tap OK (diff=0.0025mm, stable 2/5)
probe at 49.998,339.999 is z=486.110000
Tap OK (diff=0.0050mm, stable 3/5)
Tap OK (diff=0.0075mm, stable 4/5)
Tap OK (diff=0.0025mm, stable 5/5)
VALIDATED: trigger_z=486.1050 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
probe at 49.998,339.999 is z=486.100000
Tap OK (diff=0.0050mm, stable 2/5)
Tap OK (diff=0.0025mm, stable 3/5)
probe at 49.998,339.999 is z=486.107500
VALIDATED: trigger_z=486.1075 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Tap OK (diff=0.0000mm, stable 2/5)
Tap OK (diff=0.0025mm, stable 4/5)
VALIDATED: trigger_z=486.1025 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
probe at 49.998,339.999 is z=486.097500
Tap OK (diff=0.0000mm, stable 4/5)
Tap OK (diff=0.0000mm, stable 3/5)
Tap OK (diff=0.0075mm, stable 5/5)
VALIDATED: trigger_z=486.0975 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
VALIDATED: trigger_z=486.1000 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
|
| Screws tilt | PASS | 04:57:55 |
probe: at 54.997,328.001 bed will contact at z=1.152500
probe: at 54.997,328.001 bed will contact at z=1.147500
probe: at 54.997,328.001 bed will contact at z=1.155000
probe: at 380.001,328.001 bed will contact at z=1.325000
probe: at 380.001,328.001 bed will contact at z=1.315000
probe: at 380.001,328.001 bed will contact at z=1.330000
probe: at 380.001,101.996 bed will contact at z=1.202500
probe: at 380.001,101.996 bed will contact at z=1.195000
probe: at 380.001,101.996 bed will contact at z=1.185000
probe: at 54.997,101.996 bed will contact at z=1.205000
probe: at 54.997,101.996 bed will contact at z=1.202500
probe: at 54.997,101.996 bed will contact at z=1.207500
probe: at 217.505,214.498 bed will contact at z=1.270000
probe: at 217.505,214.498 bed will contact at z=1.255000
probe: at 217.505,214.498 bed will contact at z=1.202500
Probe samples exceed tolerance. Retrying...
probe: at 217.505,214.498 bed will contact at z=1.250000
probe: at 217.505,214.498 bed will contact at z=1.307500
probe: at 217.505,214.498 bed will contact at z=1.245000
probe: at 217.505,214.498 bed will contact at z=1.275000
01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
front left screw (base) : x=72.0, y=298.0, z=1.15250
front right screw : x=397.0, y=298.0, z=1.32500 : adjust CW 00:21
rear right screw : x=397.0, y=72.0, z=1.19500 : adjust CW 00:05
rear left screw : x=72.0, y=72.0, z=1.20500 : adjust CW 00:06
middle : x=234.5, y=184.5, z=1.25000 : adjust CW 00:12
|