← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

520046000D51353234323830

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 110V · 550W · SSR SSR10DA
QC pad (MAC) : 0281EB778EE3
Start : 2026-08-01T04:34:22.115407 · End : 2026-08-01T04:46:08.946529 · Duration : 706 s
Received (server) : 2026-08-01T04:49:00
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=110V bedw=550 ssr=SSR10DA lot=20260618 uid=2ACAAE

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 04:34:22
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=550;ssr=SSR10DA;lot=20260618;uid=2ACAAE [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=520046000D51353234323830
Home X PASS 04:34:48
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=457.1797 gap=1.8203 (2/4) tap 4: pos=457.7769 gap=1.2231 (3/4) tap 5: pos=457.7769 gap=1.2231 fenetre=0.7800/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=457.4326 spread=0.7800mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 04:35:28
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-18.0091 gap=1.9909 (2/4) tap 4: pos=-17.9847 gap=2.0153 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0244/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0244mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 04:36:07
Part fan PASS 04:36:10
Hotend fan PASS 04:36:12
Hotend heat 220°C PASS 04:36:12
Bed heat 60°C PASS 04:36:12
Cutter (feed+cut) PASS 04:37:43
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=457.1797 gap=1.8203 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.8141 gap=2.1859 fenetre=0.3656/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.3656mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 04:37:58
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 04:40:51
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=410.345000 probe at 49.995,339.999 is z=410.347500 Tap OK (diff=0.0025mm, stable 2/5) probe at 49.995,339.999 is z=410.337500 Tap OK (diff=0.0100mm, stable 3/5) probe at 49.995,339.999 is z=410.332500 Tap OK (diff=0.0050mm, stable 4/5) Tap OK (diff=0.0050mm, stable 5/5) VALIDATED: trigger_z=410.3375 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete!
Z tap repeatability PASS 04:45:30 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.0900, 486.1125, 486.1000, 486.1000, 486.1025, 486.1000, 486.1000, 486.1000, 486.1000, 486.1000, 486.1000, 486.1000, 486.1000, 486.1000, 486.1050
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=450.792500 probe at 49.998,339.999 is z=375.125000 Tap drift (diff=75.6675mm) — reset probe at 49.998,339.999 is z=377.835000 Tap drift (diff=2.7100mm) — reset probe at 49.998,339.999 is z=304.177500 Tap drift (diff=73.6575mm) — reset probe at 49.998,339.999 is z=306.702500 Tap drift (diff=2.5250mm) — reset probe at 49.998,339.999 is z=264.597500 Tap drift (diff=42.1050mm) — reset probe at 49.998,339.999 is z=257.822500 Tap drift (diff=6.7750mm) — reset probe at 49.998,339.999 is z=1.080000 Tap drift (diff=256.7425mm) — reset probe at 49.998,339.999 is z=1.087500 Tap OK (diff=0.0075mm, stable 2/5) probe at 49.998,339.999 is z=1.085000 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0025mm, stable 4/5) probe at 49.998,339.999 is z=1.090000 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=1.0900 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete! probe at 49.998,339.999 is z=486.110000 probe at 49.998,339.999 is z=486.112500 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0000mm, stable 4/5) VALIDATED: trigger_z=486.1125 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,339.999 is z=486.100000 Tap OK (diff=0.0000mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=486.1000 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,339.999 is z=486.097500 probe at 49.998,339.999 is z=486.102500 VALIDATED: trigger_z=486.1025 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Screws tilt PASS 04:46:08
probe: at 54.997,328.001 bed will contact at z=1.672500 probe: at 54.997,328.001 bed will contact at z=1.662500 probe: at 54.997,328.001 bed will contact at z=1.660000 probe: at 380.001,328.001 bed will contact at z=1.642500 probe: at 380.001,328.001 bed will contact at z=1.627500 probe: at 380.001,328.001 bed will contact at z=1.617500 probe: at 380.001,101.996 bed will contact at z=1.560000 probe: at 380.001,101.996 bed will contact at z=1.570000 probe: at 380.001,101.996 bed will contact at z=1.577500 probe: at 54.997,101.996 bed will contact at z=1.650000 probe: at 54.997,101.996 bed will contact at z=1.657500 probe: at 54.997,101.996 bed will contact at z=1.660000 probe: at 217.505,214.498 bed will contact at z=1.665000 probe: at 217.505,214.498 bed will contact at z=1.690000 probe: at 217.505,214.498 bed will contact at z=1.677500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=1.66250 front right screw : x=397.0, y=298.0, z=1.62750 : adjust CCW 00:04 rear right screw : x=397.0, y=72.0, z=1.57000 : adjust CCW 00:11 rear left screw : x=72.0, y=72.0, z=1.65750 : adjust CCW 00:01 middle : x=234.5, y=184.5, z=1.67750 : adjust CW 00:02