← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

52005C000C51353234323830

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 220V · 750W · SSR SSR10DA
QC pad (MAC) : 02813B23751D
Start : 2026-08-13T05:00:39.243907 · End : 2026-08-13T05:14:41.825710 · Duration : 842 s
Received (server) : 2026-08-13T05:30:04
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=750 ssr=SSR10DA lot=20260618 uid=9221AF

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 05:00:39
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=52005C000C51353234323830
Home X PASS 05:01:05
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=457.1797 gap=1.8203 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.8141 gap=2.1859 fenetre=0.3656/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.3656mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 05:01:41
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.7525 gap=1.2475 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-18.0091 gap=1.9909 (2/4) tap 4: pos=-17.9847 gap=2.0153 (3/4) tap 5: pos=-18.0091 gap=1.9909 fenetre=0.0244/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9999 spread=0.0244mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 05:01:45
Part fan PASS 05:01:47
Hotend fan PASS 05:01:50
Hotend heat 220°C PASS 05:02:01
Bed heat 60°C PASS 05:02:01
Cutter (feed+cut) PASS 05:03:30
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=457.1797 gap=1.8203 (3/4) tap 5: pos=456.8141 gap=2.1859 fenetre=0.3656/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.3656mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-18.0091 gap=1.9909 fenetre=0.0122/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9999 spread=0.0122mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 05:03:44
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 05:07:01
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=457.1797 gap=1.8203 (1/4) tap 3: pos=456.8141 gap=2.1859 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.3656/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.3656mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=-18.0091 gap=1.9909 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0122/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9999 spread=0.0122mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=495.877500 probe at 49.995,339.999 is z=487.402500 Tap drift (diff=8.4750mm) — reset probe at 49.995,339.999 is z=480.575000 Tap drift (diff=6.8275mm) — reset probe at 49.995,339.999 is z=477.610000 Tap drift (diff=2.9650mm) — reset probe at 49.995,339.999 is z=480.352500 Tap drift (diff=2.7425mm) — reset Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10) probe at 49.995,339.999 is z=483.092500 Tap drift (diff=2.7400mm) — reset probe at 49.995,339.999 is z=480.350000 probe at 49.995,339.999 is z=470.655000 Tap drift (diff=9.6950mm) — reset probe at 49.995,339.999 is z=473.400000 Tap drift (diff=2.7450mm) — reset probe at 49.995,339.999 is z=476.160000 Tap drift (diff=2.7600mm) — reset probe at 49.995,339.999 is z=479.127500 Tap drift (diff=2.9675mm) — reset
Z tap repeatability PASS 05:14:01 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.0800, 486.1100, 486.1025, 486.1000, 486.1000, 486.0950, 486.1050, 486.1025, 486.1025, 486.0950, 486.1050, 486.1100, 486.0975, 486.1025, 486.1000
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=495.780000 probe at 49.998,339.999 is z=498.565000 Tap rejete (vibration chassis, z=498.5650 > max-z_hop) -> pas de remontee, on poursuit la descente (1) probe at 49.998,339.999 is z=420.017500 probe at 49.998,339.999 is z=422.780000 Tap drift (diff=2.7625mm) — reset probe at 49.998,339.999 is z=326.045000 Tap drift (diff=96.7350mm) — reset probe at 49.998,339.999 is z=328.955000 Tap drift (diff=2.9100mm) — reset probe at 49.998,339.999 is z=331.732500 Tap drift (diff=2.7775mm) — reset probe at 49.998,339.999 is z=334.517500 Tap drift (diff=2.7850mm) — reset probe at 49.998,339.999 is z=337.295000 probe at 49.998,339.999 is z=340.077500 Tap drift (diff=2.7825mm) — reset probe at 49.998,339.999 is z=342.852500 Tap drift (diff=2.7750mm) — reset probe at 49.998,339.999 is z=345.640000 Tap drift (diff=2.7875mm) — reset probe at 49.998,339.999 is z=348.420000 Tap drift (diff=2.7800mm) — reset probe at 49.998,339.999 is z=351.200000 probe at 49.998,339.999 is z=353.987500 probe at 49.998,339.999 is z=356.767500 probe at 49.998,339.999 is z=359.517500 Tap drift (diff=2.7500mm) — reset probe at 49.998,339.999 is z=362.297500 probe at 49.998,339.999 is z=365.082500 probe at 49.998,339.999 is z=367.865000 probe at 49.998,339.999 is z=370.645000 probe at 49.998,339.999 is z=373.432500 probe at 49.998,339.999 is z=376.202500 Tap drift (diff=2.7700mm) — reset probe at 49.998,339.999 is z=378.985000 probe at 49.998,339.999 is z=381.762500 probe at 49.998,339.999 is z=384.550000
Screws tilt PASS 05:14:41
probe: at 54.997,328.001 bed will contact at z=0.837500 probe: at 54.997,328.001 bed will contact at z=0.845000 probe: at 54.997,328.001 bed will contact at z=0.842500 probe: at 380.001,328.001 bed will contact at z=0.777500 probe: at 380.001,328.001 bed will contact at z=0.812500 probe: at 380.001,328.001 bed will contact at z=0.785000 probe: at 380.001,101.996 bed will contact at z=0.835000 probe: at 380.001,101.996 bed will contact at z=0.790000 probe: at 380.001,101.996 bed will contact at z=0.817500 probe: at 54.997,101.996 bed will contact at z=0.820000 probe: at 54.997,101.996 bed will contact at z=0.825000 probe: at 54.997,101.996 bed will contact at z=0.837500 probe: at 217.505,214.498 bed will contact at z=0.797500 probe: at 217.505,214.498 bed will contact at z=0.787500 probe: at 217.505,214.498 bed will contact at z=0.802500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=0.84250 front right screw : x=397.0, y=298.0, z=0.78500 : adjust CCW 00:07 rear right screw : x=397.0, y=72.0, z=0.81750 : adjust CCW 00:03 rear left screw : x=72.0, y=72.0, z=0.82500 : adjust CCW 00:02 middle : x=234.5, y=184.5, z=0.79750 : adjust CCW 00:05