← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

520068001051353135323934

PASS Grade A Grade B
Model : C335 · Batch : 20260618
Heated bed : 220V · 500W · SSR SSR10DA
QC pad (MAC) : 0281EB778EE3
Start : 2026-07-24T00:52:09.243460 · End : 2026-07-24T01:04:20.283240 · Duration : 731 s
Received (server) : 2026-07-24T01:08:01
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C335 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=500 ssr=SSR10DA lot=20260618 uid=36C6E9

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 00:52:09
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=500;ssr=SSR10DA;lot=20260618;uid=36C6E9 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=520068001051353135323934
Home X PASS 00:52:35
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.7525 gap=1.2475 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000
Home Y PASS 00:53:06
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 00:53:50
Part fan PASS 00:53:52
Hotend fan PASS 00:53:55
Hotend heat 220°C PASS 00:53:55
Bed heat 60°C PASS 00:53:55
Cutter (feed+cut) PASS 00:55:21
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.7525 gap=1.2475 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 00:55:31
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 50mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 00:58:26
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.7525 gap=1.2475 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.996,275.995 is z=386.372500 probe at 65.996,275.995 is z=352.920000 Tap drift (diff=33.4525mm) — reset probe at 65.996,275.995 is z=310.652500 Tap drift (diff=42.2675mm) — reset probe at 65.996,275.995 is z=313.252500 Tap drift (diff=2.6000mm) — reset probe at 65.996,275.995 is z=310.742500 Tap drift (diff=2.5100mm) — reset probe at 65.996,275.995 is z=310.797500 Tap drift (diff=0.0550mm) — reset probe at 65.996,275.995 is z=310.810000 Tap drift (diff=0.0125mm) — reset probe at 65.996,275.995 is z=310.815000 Tap OK (diff=0.0050mm, stable 2/5) probe at 65.996,275.995 is z=310.822500 Tap OK (diff=0.0075mm, stable 3/5) probe at 65.996,275.995 is z=310.827500 Tap OK (diff=0.0050mm, stable 4/5) probe at 65.996,275.995 is z=310.830000 Tap OK (diff=0.0025mm, stable 5/5)
Z tap repeatability PASS 01:03:49 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.9625, 385.9050, 385.9175, 385.8850, 385.9175, 385.8725, 385.9025, 385.9275, 385.9000, 385.9000, 385.9025, 385.9025, 385.9000, 385.9000, 385.9000
Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.999,275.995 is z=395.730000 probe at 65.999,275.995 is z=398.482500 Tap rejete (vibration chassis, z=398.4825 > max-z_hop) -> pas de remontee, on poursuit la descente (1) probe at 65.999,275.995 is z=363.520000 probe at 65.999,275.995 is z=366.310000 Tap drift (diff=2.7900mm) — reset probe at 65.999,275.995 is z=369.075000 Tap drift (diff=2.7650mm) — reset probe at 65.999,275.995 is z=371.850000 Tap drift (diff=2.7750mm) — reset probe at 65.999,275.995 is z=374.632500 Tap drift (diff=2.7825mm) — reset probe at 65.999,275.995 is z=377.400000 Tap drift (diff=2.7675mm) — reset Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10) probe at 65.999,275.995 is z=380.187500 Tap drift (diff=2.7875mm) — reset probe at 65.999,275.995 is z=382.202500 Tap drift (diff=2.0150mm) — reset probe at 65.999,275.995 is z=384.957500 Tap drift (diff=2.7550mm) — reset probe at 65.999,275.995 is z=387.887500 Tap drift (diff=2.9300mm) — reset probe at 65.999,275.995 is z=390.480000 Tap drift (diff=2.5925mm) — reset probe at 65.999,275.995 is z=392.920000 Tap drift (diff=2.4400mm) — reset probe at 65.999,275.995 is z=395.827500 Tap drift (diff=2.9075mm) — reset probe at 65.999,275.995 is z=398.767500 Tap rejete (vibration chassis, z=398.7675 > max-z_hop) -> pas de remontee, on poursuit la descente (2) probe at 65.999,275.995 is z=398.757500 Tap rejete (vibration chassis, z=398.7575 > max-z_hop) -> pas de remontee, on poursuit la descente (3) probe at 65.999,275.995 is z=397.202500 Tap rejete (vibration chassis, z=397.2025 > max-z_hop) -> pas de remontee, on poursuit la descente (4) probe at 65.999,275.995 is z=0.927500 probe at 65.999,275.995 is z=0.950000 Tap drift (diff=0.0225mm) — reset
Screws tilt PASS 01:04:20
probe: at 67.000,271.004 bed will contact at z=1.087500 probe: at 67.000,271.004 bed will contact at z=1.127500 probe: at 67.000,271.004 bed will contact at z=1.100000 probe: at 267.996,271.004 bed will contact at z=1.060000 probe: at 267.996,271.004 bed will contact at z=1.072500 probe: at 267.996,71.995 bed will contact at z=1.140000 probe: at 267.996,71.995 bed will contact at z=1.145000 probe: at 267.996,71.995 bed will contact at z=1.130000 probe: at 67.000,71.995 bed will contact at z=1.087500 probe: at 67.000,71.995 bed will contact at z=1.120000 probe: at 67.000,71.995 bed will contact at z=1.077500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=84.0, y=241.0, z=1.10000 front right screw : x=285.0, y=241.0, z=1.06000 : adjust CCW 00:05 rear right screw : x=285.0, y=42.0, z=1.14000 : adjust CW 00:05 rear left screw : x=84.0, y=42.0, z=1.08750 : adjust CCW 00:01