SmartPi 1
SmartPi 2

530029001051353135323934

PASS Grade A Grade B
Model : C235 · Batch : 20260616
Heated bed : 220V · 300W · SSR SSR10DA
QC pad (MAC) : 0281762516E2
Start : 2026-06-25T08:47:46.154743 · End : 2026-06-25T09:00:50.248713 · Duration : 784 s
Received (server) : 2026-06-25T09:12:27
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C235 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=300 ssr=SSR10DA lot=20260616 uid=61C229

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 08:47:46
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C235;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=300;ssr=SSR10DA;lot=20260616;uid=61C229 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=530029001051353135323934
Home X PASS 08:48:12
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.5819 gap=1.4181 (chauffe, ignore) tap 2: pos=256.7769 gap=1.2231 (1/4) tap 3: pos=256.7769 gap=1.2231 (2/4) tap 4: pos=256.7891 gap=1.2109 (3/4) tap 5: pos=256.7647 gap=1.2353 fenetre=0.0244/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=256.7769 spread=0.0244mm (tol=0.0500). Zero pose en butee=256.0000
Home Y PASS 08:48:44
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 08:48:53
Part fan PASS 08:49:04
Hotend fan PASS 08:50:26
Hotend heat 220°C PASS 08:50:26
Bed heat 60°C PASS 08:50:26
Cutter (feed+cut) PASS 08:52:25
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=256.7891 gap=1.2109 (1/4) tap 3: pos=256.7769 gap=1.2231 (2/4) tap 4: pos=256.7647 gap=1.2353 (3/4) tap 5: pos=256.7769 gap=1.2231 fenetre=0.0244/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=256.7769 spread=0.0244mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1797 gap=1.8203 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 08:52:48
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 125mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 08:54:49
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.6062 gap=1.3938 (chauffe, ignore) tap 2: pos=256.5819 gap=1.4181 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=256.1919 gap=1.8081 (3/4) tap 5: pos=255.9847 gap=2.0153 fenetre=0.5972/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=256.1888 spread=0.5972mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 31.003,211.998 is z=184.557500 probe at 31.003,211.998 is z=187.075000 Tap drift (diff=2.5175mm) — reset probe at 31.003,211.998 is z=184.562500 Tap drift (diff=2.5125mm) — reset Tap OK (diff=0.0000mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=184.5625 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete!
Z tap repeatability PASS 09:00:22 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.9125, 255.9075, 255.9000, 255.9025, 255.9000, 255.9025, 255.9025, 255.8900, 255.9150, 255.9025, 255.9000, 255.9000, 255.9050, 255.9000, 255.9000
Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 30.994,211.998 is z=0.902500 probe at 30.994,211.998 is z=0.910000 Tap OK (diff=0.0075mm, stable 2/5) probe at 30.994,211.998 is z=3.450000 Tap drift (diff=2.5400mm) — reset probe at 30.994,211.998 is z=0.907500 Tap drift (diff=2.5425mm) — reset probe at 30.994,211.998 is z=0.912500 Tap OK (diff=0.0050mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 30.994,211.998 is z=3.452500 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=0.9125 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete! probe at 30.994,211.998 is z=255.895000 probe at 30.994,211.998 is z=255.900000 probe at 30.994,211.998 is z=255.902500 Tap OK (diff=0.0025mm, stable 3/5) probe at 30.994,211.998 is z=258.442500 probe at 30.994,211.998 is z=255.897500 Tap drift (diff=2.5450mm) — reset probe at 30.994,211.998 is z=258.435000 Tap drift (diff=2.5375mm) — reset probe at 30.994,211.998 is z=258.437500 Tap drift (diff=2.5350mm) — reset probe at 30.994,211.998 is z=255.905000 probe at 30.994,211.998 is z=258.440000 Tap drift (diff=2.5300mm) — reset Tap drift (diff=2.5325mm) — reset probe at 30.994,211.998 is z=255.915000 Tap drift (diff=2.5225mm) — reset Tap OK (diff=0.0100mm, stable 2/5) probe at 30.994,211.998 is z=255.907500 probe at 30.994,211.998 is z=255.917500 Tap drift (diff=2.5200mm) — reset
Screws tilt PASS 09:00:50
probe: at 32.495,205.497 bed will contact at z=1.210000 probe: at 32.495,205.497 bed will contact at z=1.197500 probe: at 206.996,205.497 bed will contact at z=1.222500 probe: at 206.996,205.497 bed will contact at z=1.237500 probe: at 206.996,205.497 bed will contact at z=1.242500 probe: at 206.996,31.995 bed will contact at z=0.070000 probe: at 206.996,31.995 bed will contact at z=0.087500 probe: at 206.996,31.995 bed will contact at z=0.095000 probe: at 32.495,31.995 bed will contact at z=-0.395000 probe: at 32.495,31.995 bed will contact at z=-0.362500 probe: at 32.495,31.995 bed will contact at z=-0.390000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=49.5, y=175.5, z=1.19750 front right screw : x=224.0, y=175.5, z=1.23750 : adjust CW 00:05 rear right screw : x=224.0, y=2.0, z=0.08750 : adjust CCW 02:13 rear left screw : x=49.5, y=2.0, z=-0.39000 : adjust CCW 03:10

History — 4 reports for this machine

QC dateResultQC pad (MAC)Received (server)
2026-06-25T08:47:46.154743 PASS 530029001051353135323934 2026-06-25T09:12:27
2026-06-25T08:29:00.042377 FAIL 530029001051353135323934 2026-06-25T08:38:37
2026-06-18T02:40:07.838279 FAIL 530029001051353135323934 2026-06-18T03:14:13
2026-06-18T01:56:10.468388 FAIL 530029001051353135323934 2026-06-18T02:37:44