| Test | Result | Time | Details / log |
|---|---|---|---|
| MCU + firmware | PASS | 01:08:48 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=500;ssr=SSR10DA;lot=20260618;uid=36C6E9
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=54002A001051353135323934
|
| Home X | PASS | 01:09:15 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=357.7525 gap=1.2475 (chauffe, ignore)
tap 2: pos=357.0091 gap=1.9909 (1/4)
tap 3: pos=356.9969 gap=2.0031 (2/4)
tap 4: pos=356.9969 gap=2.0031 (3/4)
tap 5: pos=356.9969 gap=2.0031 fenetre=0.0122/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9999 spread=0.0122mm (tol=0.0500). Zero pose en butee=357.0000
|
| Home Y | PASS | 01:09:58 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1 rejete: cible atteinte sans buter (gap=0.0653)
tap 2: pos=-30.5941 gap=1.4059 (chauffe, ignore)
tap 3: pos=-30.5819 gap=1.4181 (1/4)
tap 4: pos=-29.9969 gap=2.0031 (2/4)
tap 5 rejete: cible atteinte sans buter (gap=0.2481)
tap 6: pos=-30.7769 gap=1.2231 (3/4)
tap 7: pos=-30.5819 gap=1.4181 fenetre=0.7800/0.0500
YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (2 rejetes) -> moyenne=-30.4844 spread=0.7800mm (tol=0.0500). Zero pose en butee=-30.0000
|
| Motherboard fan | PASS | 01:10:03 | |
| Part fan | PASS | 01:10:05 | |
| Hotend fan | PASS | 01:10:07 | |
| Hotend heat 220°C | PASS | 01:10:07 | |
| Bed heat 60°C | PASS | 01:10:14 | |
| Cutter (feed+cut) | PASS | 01:11:48 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=357.7525 gap=1.2475 (chauffe, ignore)
tap 2: pos=356.8141 gap=2.1859 (1/4)
tap 3: pos=357.1919 gap=1.8081 (2/4)
tap 4: pos=356.9847 gap=2.0153 (3/4)
tap 5: pos=356.9969 gap=2.0031 fenetre=0.3778/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.3778mm (tol=0.0500). Zero pose en butee=357.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-30.7769 gap=1.2231 (chauffe, ignore)
tap 2: pos=-30.7769 gap=1.2231 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.7800/0.0500
YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.1919 spread=0.7800mm (tol=0.0500). Zero pose en butee=-30.0000
Extruder 'extruder1' now syncing with ''
Extruder 'extruder0' now syncing with 'extruder'
QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte)
QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120
Extruder 'extruder0' now syncing with ''
|
| YMS-2 feed to head | PASS | 01:12:03 |
Extruder 'extruder0' now syncing with ''
Extruder 'extruder1' now syncing with ''
Extruder 'extruder1' now syncing with 'extruder'
QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte)
QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
|
| Z tap home + Zmax | PASS | 01:14:52 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=357.7891 gap=1.2109 (chauffe, ignore)
tap 2: pos=356.9969 gap=2.0031 (1/4)
tap 3: pos=356.9969 gap=2.0031 (2/4)
tap 4: pos=356.9969 gap=2.0031 (3/4)
tap 5 rejete: cible atteinte sans buter (gap=0.2603)
tap 6: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (1 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore)
tap 2: pos=-29.9969 gap=2.0031 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Moving to tap point X=66.0 Y=276.0...
Probing with pressure switch...
probe at 65.996,275.995 is z=315.805000
probe at 65.996,275.995 is z=315.915000
Tap drift (diff=0.1100mm) — reset
probe at 65.996,275.995 is z=315.922500
Tap OK (diff=0.0075mm, stable 2/5)
probe at 65.996,275.995 is z=315.925000
Tap OK (diff=0.0025mm, stable 3/5)
probe at 65.996,275.995 is z=315.932500
Tap OK (diff=0.0075mm, stable 4/5)
probe at 65.996,275.995 is z=315.927500
Tap OK (diff=0.0050mm, stable 5/5)
VALIDATED: trigger_z=315.9275 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0)
Z calibration complete!
|
| Z tap repeatability | PASS | 01:19:31 |
OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.8725, 385.9025, 385.9125, 385.9050, 385.9000, 385.9050, 385.9000, 385.9025, 385.9000, 385.9000, 385.9000, 385.9000, 385.9025, 385.9000, 385.9000
Moving to tap point X=66.0 Y=276.0...
Probing with pressure switch...
Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10)
probe at 65.999,275.995 is z=0.745000
probe at 65.999,275.995 is z=0.860000
Tap drift (diff=0.1150mm) — reset
probe at 65.999,275.995 is z=0.867500
Tap OK (diff=0.0075mm, stable 2/5)
probe at 65.999,275.995 is z=0.865000
Tap OK (diff=0.0025mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 4/5)
probe at 65.999,275.995 is z=0.872500
Tap OK (diff=0.0075mm, stable 5/5)
VALIDATED: trigger_z=0.8725 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0)
Z calibration complete!
probe at 65.999,275.995 is z=385.890000
probe at 65.999,275.995 is z=385.902500
Tap drift (diff=0.0125mm) — reset
probe at 65.999,275.995 is z=385.900000
Tap OK (diff=0.0025mm, stable 2/5)
probe at 65.999,275.995 is z=385.905000
Tap OK (diff=0.0025mm, stable 4/5)
Tap OK (diff=0.0025mm, stable 5/5)
VALIDATED: trigger_z=385.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 65.999,275.995 is z=385.892500
probe at 65.999,275.995 is z=385.907500
Tap drift (diff=0.0150mm) — reset
probe at 65.999,275.995 is z=385.910000
probe at 65.999,275.995 is z=385.915000
Tap OK (diff=0.0050mm, stable 3/5)
Tap OK (diff=0.0050mm, stable 4/5)
probe at 65.999,275.995 is z=385.912500
VALIDATED: trigger_z=385.9125 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 65.999,275.995 is z=385.882500
Tap drift (diff=0.0200mm) — reset
Tap OK (diff=0.0000mm, stable 2/5)
Tap OK (diff=0.0000mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=385.9050 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
|
| Screws tilt | PASS | 01:20:08 |
probe: at 67.000,271.004 bed will contact at z=0.995000
probe: at 67.000,271.004 bed will contact at z=1.012500
probe: at 67.000,271.004 bed will contact at z=1.015000
probe: at 267.996,271.004 bed will contact at z=1.032500
probe: at 267.996,271.004 bed will contact at z=1.047500
probe: at 267.996,271.004 bed will contact at z=1.120000
Probe samples exceed tolerance. Retrying...
probe: at 267.996,271.004 bed will contact at z=1.040000
probe: at 267.996,271.004 bed will contact at z=1.060000
probe: at 267.996,271.004 bed will contact at z=1.080000
probe: at 267.996,71.995 bed will contact at z=0.997500
probe: at 267.996,71.995 bed will contact at z=0.770000
probe: at 267.996,71.995 bed will contact at z=0.922500
probe: at 267.996,71.995 bed will contact at z=0.950000
probe: at 267.996,71.995 bed will contact at z=0.937500
probe: at 67.000,71.995 bed will contact at z=1.000000
probe: at 67.000,71.995 bed will contact at z=1.010000
probe: at 67.000,71.995 bed will contact at z=1.005000
01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
front left screw (base) : x=84.0, y=241.0, z=1.01250
front right screw : x=285.0, y=241.0, z=1.06000 : adjust CW 00:06
rear right screw : x=285.0, y=42.0, z=0.93750 : adjust CCW 00:09
rear left screw : x=84.0, y=42.0, z=1.00500 : adjust CCW 00:01
|
| QC date | Result | QC pad (MAC) | Received (server) |
|---|---|---|---|
| 2026-07-14T01:08:48.318921 | PASS | 54002A001051353135323934 | 2026-07-17T06:38:10 |
| 2026-07-13T05:30:36.382925 | FAIL | 54002A001051353135323934 | 2026-07-17T06:38:08 |