| Test | Result | Time | Details / log |
|---|---|---|---|
| MCU + firmware | PASS | 07:22:34 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=54002F001051353135323934
|
| Home X | PASS | 07:23:02 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=54002F001051353135323934
Run Current: 0.98A Hold Current: 0.98A
YUMI_SENSORLESS_HOME X: home base... (sgthrs=50)
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=467.0213 gap=1.9787 (chauffe, ignore)
tap 2: pos=466.9969 gap=2.0031 (1/4)
tap 3: pos=466.9969 gap=2.0031 (2/4)
tap 4: pos=466.9969 gap=2.0031 (3/4)
tap 5: pos=466.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=466.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=467.0000
|
| Home Y | PASS | 07:23:39 |
Run Current: 1.20A Hold Current: 1.09A
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=466.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=467.0000
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base... (sgthrs=50)
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-21.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=-20.9969 gap=2.0031 (1/4)
tap 3: pos=-20.9969 gap=2.0031 (2/4)
tap 4: pos=-20.9969 gap=2.0031 (3/4)
tap 5: pos=-20.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-20.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-21.0000
|
| Motherboard fan | PASS | 07:23:47 | |
| Part fan | PASS | 07:23:50 | |
| Hotend fan | PASS | 07:23:54 | |
| Hotend heat 220°C | PASS | 07:23:55 | |
| Bed heat 60°C | PASS | 07:25:12 | |
| Cutter (feed+cut) | PASS | 07:28:19 |
Run Current: 0.98A Hold Current: 0.98A
YUMI_SENSORLESS_HOME X: home base... (sgthrs=50)
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=467.0091 gap=1.9909 (chauffe, ignore)
tap 2: pos=467.1919 gap=1.8081 (1/4)
tap 3: pos=466.9969 gap=2.0031 (2/4)
tap 4: pos=466.9969 gap=2.0031 (3/4)
tap 5: pos=466.8019 gap=2.1981 fenetre=0.3900/0.0500
tap 6: pos=467.1919 gap=1.8081 fenetre=0.3900/0.0500
tap 7: pos=466.9969 gap=2.0031 fenetre=0.3900/0.0500
tap 8: pos=466.9969 gap=2.0031 fenetre=0.3900/0.0500
tap 9: pos=466.9969 gap=2.0031 fenetre=0.1950/0.0500
tap 10: pos=466.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 9 taps valides (0 rejetes) -> moyenne=466.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=467.0000
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base... (sgthrs=50)
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-21.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=-20.9969 gap=2.0031 (1/4)
tap 3: pos=-20.9969 gap=2.0031 (2/4)
tap 4: pos=-20.9969 gap=2.0031 (3/4)
tap 5: pos=-20.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-20.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-21.0000
Extruder 'extruder1' now syncing with ''
Extruder 'extruder0' now syncing with 'extruder'
QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte)
QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120
Extruder 'extruder0' now syncing with ''
|
| YMS-2 feed to head | PASS | 07:28:42 |
Extruder 'extruder0' now syncing with ''
Extruder 'extruder1' now syncing with ''
Extruder 'extruder1' now syncing with 'extruder'
QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte)
QC E1_HEAD: filament a la tete apres 125mm + motion sensor YMS-2 OK
|
| Z tap home + Zmax | PASS | 07:32:04 |
Extruder 'extruder1' now syncing with ''
Run Current: 0.98A Hold Current: 0.98A
YUMI_SENSORLESS_HOME X: home base... (sgthrs=50)
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=467.3991 gap=1.6009 (chauffe, ignore)
tap 2: pos=466.9969 gap=2.0031 (1/4)
tap 3: pos=466.8019 gap=2.1981 (2/4)
tap 4: pos=467.1919 gap=1.8081 (3/4)
tap 5: pos=466.9969 gap=2.0031 fenetre=0.3900/0.0500
tap 6: pos=466.9969 gap=2.0031 fenetre=0.3900/0.0500
tap 7: pos=466.9969 gap=2.0031 fenetre=0.1950/0.0500
tap 8: pos=466.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 7 taps valides (0 rejetes) -> moyenne=466.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=467.0000
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base... (sgthrs=50)
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-21.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=-20.9969 gap=2.0031 (1/4)
tap 3: pos=-20.9969 gap=2.0031 (2/4)
tap 4: pos=-20.9969 gap=2.0031 (3/4)
tap 5: pos=-21.0091 gap=1.9909 fenetre=0.0122/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-20.9999 spread=0.0122mm (tol=0.0500). Zero pose en butee=-21.0000
Moving to tap point X=56.0 Y=334.0...
Probing with pressure switch...
probe at 55.998,334.001 is z=493.237500
probe at 55.998,334.001 is z=471.617500
Tap drift (diff=21.6200mm) — reset
probe at 55.998,334.001 is z=386.222500
Tap drift (diff=85.3950mm) — reset
probe at 55.998,334.001 is z=386.245000
Tap drift (diff=0.0225mm) — reset
probe at 55.998,334.001 is z=386.282500
Tap drift (diff=0.0375mm) — reset
probe at 55.998,334.001 is z=386.810000
Tap drift (diff=0.5275mm) — reset
probe at 55.998,334.001 is z=389.602500
Tap drift (diff=2.7925mm) — reset
probe at 55.998,334.001 is z=389.042500
Tap drift (diff=0.5600mm) — reset
probe at 55.998,334.001 is z=390.960000
Tap drift (diff=1.9175mm) — reset
probe at 55.998,334.001 is z=386.287500
Tap drift (diff=4.6725mm) — reset
probe at 55.998,334.001 is z=386.252500
Tap drift (diff=0.0350mm) — reset
probe at 55.998,334.001 is z=386.262500
Tap drift (diff=0.0100mm) — reset
probe at 55.998,334.001 is z=386.265000
Tap OK (diff=0.0025mm, stable 2/5)
probe at 55.998,334.001 is z=387.175000
Tap drift (diff=0.9100mm) — reset
probe at 55.998,334.001 is z=386.250000
Tap drift (diff=0.9250mm) — reset
probe at 55.998,334.001 is z=386.237500
Tap drift (diff=0.0125mm) — reset
probe at 55.998,334.001 is z=386.227500
Tap OK (diff=0.0100mm, stable 2/5)
probe at 55.998,334.001 is z=386.232500
Tap OK (diff=0.0050mm, stable 3/5)
Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10)
probe at 55.998,334.001 is z=389.010000
Tap drift (diff=2.7775mm) — reset
probe at 55.998,334.001 is z=391.805000
Tap drift (diff=2.7950mm) — reset
probe at 55.998,334.001 is z=386.242500
Tap drift (diff=5.5625mm) — reset
probe at 55.998,334.001 is z=386.230000
Tap OK (diff=0.0025mm, stable 4/5)
probe at 55.998,334.001 is z=386.240000
Tap OK (diff=0.0025mm, stable 3/5)
probe at 55.998,334.001 is z=388.827500
Tap drift (diff=2.5875mm) — reset
probe at 55.998,334.001 is z=386.217500
Tap drift (diff=2.6100mm) — reset
probe at 55.998,334.001 is z=386.235000
Tap OK (diff=0.0075mm, stable 4/5)
probe at 55.998,334.001 is z=388.572500
Tap drift (diff=2.3375mm) — reset
Tap drift (diff=2.3425mm) — reset
probe at 55.998,334.001 is z=389.007500
Tap drift (diff=2.7650mm) — reset
Tap OK (diff=0.0050mm, stable 2/5)
Tap OK (diff=0.0000mm, stable 4/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=386.2325 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Maillage OK (config): zero_reference_position (56.0, 334.0) ~ point de tap (56.0, 334.0)
Z calibration complete!
|
| Z tap repeatability | PASS | 07:38:33 |
OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 30 taps | taps=1.1200, 1.1200, 486.1000, 486.1000, 486.1025, 486.1025, 486.1075, 486.1075, 486.0925, 486.0925, 486.1000, 486.1000, 486.1100, 486.1100, 486.0950, 486.0950, 486.1025, 486.1025, 486.1050, 486.1050, 486.1025, 486.1025, 486.1000, 486.1000, 486.1000, 486.1000, 486.0925, 486.0925, 486.1050, 486.1050
Moving to tap point X=56.0 Y=334.0...
Probing with pressure switch...
probe at 56.001,334.001 is z=495.757500
probe at 56.001,334.001 is z=498.530000
Tap rejete (vibration chassis, z=498.5300 > max-z_hop) -> pas de remontee, on poursuit la descente (1)
probe at 56.001,334.001 is z=459.230000
Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10)
Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (2/10)
probe at 56.001,334.001 is z=341.242500
Tap drift (diff=117.9875mm) — reset
probe at 56.001,334.001 is z=337.400000
Tap drift (diff=3.8425mm) — reset
probe at 56.001,334.001 is z=339.992500
Tap drift (diff=2.5925mm) — reset
probe at 56.001,334.001 is z=264.215000
Tap drift (diff=75.7775mm) — reset
probe at 56.001,334.001 is z=265.935000
Tap drift (diff=1.7200mm) — reset
probe at 56.001,334.001 is z=268.710000
Tap drift (diff=2.7750mm) — reset
probe at 56.001,334.001 is z=198.980000
Tap drift (diff=69.7300mm) — reset
probe at 56.001,334.001 is z=201.480000
Tap drift (diff=2.5000mm) — reset
probe at 56.001,334.001 is z=157.325000
Tap drift (diff=44.1550mm) — reset
probe at 56.001,334.001 is z=151.360000
Tap drift (diff=5.9650mm) — reset
probe at 56.001,334.001 is z=1.090000
Tap drift (diff=150.2700mm) — reset
probe at 56.001,334.001 is z=1.100000
Tap drift (diff=0.0100mm) — reset
probe at 56.001,334.001 is z=1.102500
Tap OK (diff=0.0025mm, stable 2/5)
probe at 56.001,334.001 is z=1.112500
Tap OK (diff=0.0000mm, stable 2/5)
probe at 56.001,334.001 is z=1.707500
Tap drift (diff=0.5950mm) — reset
probe at 56.001,334.001 is z=1.117500
Tap drift (diff=0.5900mm) — reset
probe at 56.001,334.001 is z=4.065000
Tap drift (diff=2.9475mm) — reset
probe at 56.001,334.001 is z=6.832500
Tap drift (diff=2.7675mm) — reset
probe at 56.001,334.001 is z=9.640000
Tap drift (diff=2.8075mm) — reset
probe at 56.001,334.001 is z=1.110000
Tap drift (diff=8.5300mm) — reset
probe at 56.001,334.001 is z=1.132500
Tap drift (diff=0.0200mm) — reset
Tap drift (diff=0.0150mm) — reset
probe at 56.001,334.001 is z=1.125000
Tap OK (diff=0.0075mm, stable 2/5)
probe at 56.001,334.001 is z=1.120000
Tap OK (diff=0.0050mm, stable 3/5)
Tap OK (diff=0.0025mm, stable 4/5)
probe at 56.001,334.001 is z=4.107500
Tap drift (diff=2.9900mm) — reset
probe at 56.001,334.001 is z=6.027500
Tap drift (diff=1.9200mm) — reset
Tap drift (diff=4.9150mm) — reset
probe at 56.001,334.001 is z=1.115000
Tap OK (diff=0.0025mm, stable 3/5)
probe at 56.001,334.001 is z=1.122500
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=1.1200 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Maillage OK (config): zero_reference_position (56.0, 334.0) ~ point de tap (56.0, 334.0)
Z calibration complete!
probe at 56.001,334.001 is z=495.332500
probe at 56.001,334.001 is z=486.095000
Tap drift (diff=9.2375mm) — reset
probe at 56.001,334.001 is z=486.107500
Tap drift (diff=0.0125mm) — reset
probe at 56.001,334.001 is z=486.102500
Tap OK (diff=0.0050mm, stable 2/5)
probe at 56.001,334.001 is z=486.100000
probe at 56.001,334.001 is z=486.097500
Tap OK (diff=0.0025mm, stable 5/5)
VALIDATED: trigger_z=486.1000 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Tap OK (diff=0.0000mm, stable 4/5)
VALIDATED: trigger_z=486.1025 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Tap OK (diff=0.0075mm, stable 5/5)
VALIDATED: trigger_z=486.1075 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Tap OK (diff=0.0000mm, stable 3/5)
probe at 56.001,334.001 is z=486.092500
VALIDATED: trigger_z=486.0925 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
probe at 56.001,334.001 is z=486.110000
probe at 56.001,334.001 is z=486.105000
Tap OK (diff=0.0050mm, stable 4/5)
VALIDATED: trigger_z=486.1100 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
VALIDATED: trigger_z=486.0950 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
probe at 56.001,334.001 is z=488.907500
Tap drift (diff=2.8025mm) — reset
Tap drift (diff=2.8100mm) — reset
probe at 56.001,334.001 is z=488.620000
Tap drift (diff=2.5225mm) — reset
Tap drift (diff=2.5150mm) — reset
probe at 56.001,334.001 is z=488.952500
Tap drift (diff=2.8475mm) — reset
Tap drift (diff=2.8500mm) — reset
Tap OK (diff=0.0050mm, stable 5/5)
probe at 56.001,334.001 is z=488.887500
Tap drift (diff=2.7900mm) — reset
Tap drift (diff=2.7875mm) — reset
VALIDATED: trigger_z=486.1050 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Tap OK (diff=0.0075mm, stable 3/5)
probe at 56.001,334.001 is z=488.602500
Tap drift (diff=2.4950mm) — reset
Tap drift (diff=2.5050mm) — reset
probe at 56.001,334.001 is z=486.090000
probe at 56.001,334.001 is z=486.907500
Tap drift (diff=0.8100mm) — reset
Tap drift (diff=0.8125mm) — reset
probe at 56.001,334.001 is z=487.790000
Tap drift (diff=1.6950mm) — reset
Tap drift (diff=1.7000mm) — reset
probe at 56.001,334.001 is z=488.882500
Tap drift (diff=2.7850mm) — reset
Tap drift (diff=2.7825mm) — reset
probe at 56.001,334.001 is z=495.795000
Tap drift (diff=9.6975mm) — reset
Tap drift (diff=2.7925mm) — reset
probe at 56.001,334.001 is z=495.790000
Tap drift (diff=9.6875mm) — reset
|
| Screws tilt | PASS | 07:39:11 |
Maillage OK (config): zero_reference_position (56.0, 334.0) ~ point de tap (56.0, 334.0)
Z calibration complete!
probe: at 56.003,334.994 bed will contact at z=1.490000
probe: at 56.003,334.994 bed will contact at z=1.487500
probe: at 56.003,334.994 bed will contact at z=1.480000
probe: at 388.002,334.994 bed will contact at z=1.435000
probe: at 388.002,334.994 bed will contact at z=1.425000
probe: at 388.002,334.994 bed will contact at z=1.440000
probe: at 388.002,110.001 bed will contact at z=1.447500
probe: at 388.002,110.001 bed will contact at z=1.445000
probe: at 388.002,110.001 bed will contact at z=1.477500
probe: at 56.003,110.001 bed will contact at z=1.502500
probe: at 56.003,110.001 bed will contact at z=1.515000
probe: at 56.003,110.001 bed will contact at z=1.530000
probe: at 221.996,222.004 bed will contact at z=1.465000
probe: at 221.996,222.004 bed will contact at z=1.555000
Probe samples exceed tolerance. Retrying...
probe: at 221.996,222.004 bed will contact at z=1.560000
01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
front left screw (base) : x=73.0, y=305.0, z=1.48750
front right screw : x=405.0, y=305.0, z=1.43500 : adjust CCW 00:06
rear right screw : x=405.0, y=80.0, z=1.44750 : adjust CCW 00:05
rear left screw : x=73.0, y=80.0, z=1.51500 : adjust CW 00:03
rear middle screw : x=239.0, y=192.0, z=1.55500 : adjust CW 00:08
|
Moves this report to the trash — you can restore it from /trash.