| Test | Result | Time | Details / log |
|---|---|---|---|
| MCU + firmware | PASS | 13:53:03 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=550;ssr=SSR10DA;lot=20260618;uid=2ACAAE
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=540031001051353135323934
|
| Home X | PASS | 13:53:30 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.9597 gap=1.0403 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
|
| Home Y | PASS | 13:54:05 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-30.8012 gap=1.1988 (chauffe, ignore)
tap 2: pos=-29.9969 gap=2.0031 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-30.1797 gap=1.8203 (3/4)
tap 5: pos=-30.5941 gap=1.4059 fenetre=0.5972/0.0500
YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.1919 spread=0.5972mm (tol=0.0500). Zero pose en butee=-30.0000
|
| Motherboard fan | PASS | 13:54:20 | |
| Part fan | PASS | 13:54:23 | |
| Hotend fan | PASS | 13:54:34 | |
| Hotend heat 220°C | PASS | 13:54:34 | |
| Bed heat 60°C | PASS | 13:55:15 | |
| Cutter (feed+cut) | PASS | 13:59:34 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.9475 gap=1.0525 (chauffe, ignore)
tap 2: pos=456.8141 gap=2.1859 (1/4)
tap 3: pos=457.1797 gap=1.8203 (2/4)
tap 4: pos=456.8141 gap=2.1859 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.3656/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9512 spread=0.3656mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore)
tap 2: pos=-29.9969 gap=2.0031 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Extruder 'extruder1' now syncing with ''
Extruder 'extruder0' now syncing with 'extruder'
QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte)
QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120
Extruder 'extruder0' now syncing with ''
|
| YMS-2 feed to head | PASS | 14:00:17 |
Extruder 'extruder0' now syncing with ''
Extruder 'extruder1' now syncing with ''
Extruder 'extruder1' now syncing with 'extruder'
QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte)
QC E1_HEAD: filament a la tete apres 275mm + motion sensor YMS-2 OK
|
| Z tap home + Zmax | PASS | 14:03:35 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.1919 gap=1.8081 (chauffe, ignore)
tap 2: pos=457.7647 gap=1.2353 (1/4)
tap 3: pos=456.2291 gap=2.7709 (2/4)
tap 4: pos=457.7647 gap=1.2353 (3/4)
tap 5: pos=456.2291 gap=2.7709 fenetre=1.5356/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=1.5356mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-30.7769 gap=1.2231 (chauffe, ignore)
tap 2: pos=-30.1797 gap=1.8203 (1/4)
tap 3: pos=-30.5941 gap=1.4059 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.5972/0.0500
YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.1919 spread=0.5972mm (tol=0.0500). Zero pose en butee=-30.0000
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.995,340.003 is z=385.827500
probe at 49.995,340.003 is z=385.837500
Tap drift (diff=0.0100mm) — reset
Tap OK (diff=0.0000mm, stable 2/5)
probe at 49.995,340.003 is z=385.835000
Tap OK (diff=0.0025mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 4/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=385.8350 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z calibration complete!
|
| Z tap repeatability | PASS | 14:09:01 |
OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.7275, 486.1025, 486.1075, 486.0950, 486.1075, 486.1050, 486.0900, 486.1075, 486.0950, 486.1025, 486.1025, 486.1000, 486.1000, 486.1200, 486.1050
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.998,340.003 is z=308.647500
probe at 49.998,340.003 is z=1.692500
Tap drift (diff=306.9550mm) — reset
probe at 49.998,340.003 is z=1.690000
Tap OK (diff=0.0025mm, stable 2/5)
Tap OK (diff=0.0025mm, stable 3/5)
probe at 49.998,340.003 is z=1.697500
Tap OK (diff=0.0050mm, stable 4/5)
probe at 49.998,340.003 is z=1.707500
Tap drift (diff=0.0100mm) — reset
probe at 49.998,340.003 is z=1.727500
Tap drift (diff=0.0200mm) — reset
probe at 49.998,340.003 is z=1.732500
Tap OK (diff=0.0050mm, stable 2/5)
probe at 49.998,340.003 is z=1.730000
Tap OK (diff=0.0000mm, stable 4/5)
Tap OK (diff=0.0025mm, stable 5/5)
VALIDATED: trigger_z=1.7275 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z calibration complete!
probe at 49.998,340.003 is z=486.087500
probe at 49.998,340.003 is z=486.105000
Tap drift (diff=0.0175mm) — reset
probe at 49.998,340.003 is z=486.102500
Tap OK (diff=0.0000mm, stable 3/5)
probe at 49.998,340.003 is z=486.100000
Tap OK (diff=0.0025mm, stable 4/5)
VALIDATED: trigger_z=486.1025 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
probe at 49.998,340.003 is z=486.080000
Tap drift (diff=0.0225mm) — reset
Tap OK (diff=0.0000mm, stable 2/5)
probe at 49.998,340.003 is z=486.107500
Tap OK (diff=0.0050mm, stable 3/5)
VALIDATED: trigger_z=486.1075 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
probe at 49.998,340.003 is z=486.090000
probe at 49.998,340.003 is z=486.097500
Tap OK (diff=0.0075mm, stable 2/5)
probe at 49.998,340.003 is z=486.095000
|
| Screws tilt | PASS | 14:09:59 |
probe: at 54.997,315.001 bed will contact at z=1.690000
probe: at 54.997,315.001 bed will contact at z=1.685000
probe: at 54.997,315.001 bed will contact at z=1.687500
probe: at 380.001,315.001 bed will contact at z=1.855000
probe: at 380.001,315.001 bed will contact at z=1.860000
probe: at 380.001,83.000 bed will contact at z=1.760000
probe: at 380.001,83.000 bed will contact at z=1.750000
probe: at 380.001,83.000 bed will contact at z=1.740000
probe: at 54.997,83.000 bed will contact at z=1.750000
probe: at 54.997,83.000 bed will contact at z=1.745000
probe: at 54.997,83.000 bed will contact at z=1.742500
probe: at 217.505,202.498 bed will contact at z=1.877500
probe: at 217.505,202.498 bed will contact at z=1.852500
probe: at 217.505,202.498 bed will contact at z=1.810000
Probe samples exceed tolerance. Retrying...
probe: at 217.505,202.498 bed will contact at z=1.890000
probe: at 217.505,202.498 bed will contact at z=1.845000
probe: at 217.505,202.498 bed will contact at z=1.922500
probe: at 217.505,202.498 bed will contact at z=1.942500
probe: at 217.505,202.498 bed will contact at z=1.807500
probe: at 217.505,202.498 bed will contact at z=1.855000
probe: at 217.505,202.498 bed will contact at z=1.872500
probe: at 217.505,202.498 bed will contact at z=1.910000
probe: at 217.505,202.498 bed will contact at z=1.857500
probe: at 217.505,202.498 bed will contact at z=1.915000
probe: at 217.505,202.498 bed will contact at z=1.850000
probe: at 217.505,202.498 bed will contact at z=1.802500
01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
front left screw (base) : x=72.0, y=285.0, z=1.68750
front right screw : x=397.0, y=285.0, z=1.85500 : adjust CW 00:20
rear right screw : x=397.0, y=53.0, z=1.75000 : adjust CW 00:08
rear left screw : x=72.0, y=53.0, z=1.74500 : adjust CW 00:07
rear left screw : x=234.5, y=172.5, z=1.84500 : adjust CW 00:19
|