SmartPi 1
SmartPi 2

540036001051353135323934

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 110V · 550W · SSR SSR10DA
QC pad (MAC) : 028103694A6F
Start : 2026-08-07T12:53:58.449580 · End : 2026-08-07T13:06:21.198474 · Duration : 742 s
Received (server) : 2026-08-07T05:47:07
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=110V bedw=550 ssr=SSR10DA lot=20260618 uid=2ACAAE

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 12:53:58
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=550;ssr=SSR10DA;lot=20260618;uid=2ACAAE [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=540036001051353135323934
Home X PASS 12:54:24
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 12:54:59
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1797 gap=1.8203 (chauffe, ignore) tap 2: pos=-30.7769 gap=1.2231 (1/4) tap 3: pos=-30.5819 gap=1.4181 (2/4) tap 4: pos=-30.1797 gap=1.8203 (3/4) tap 5: pos=-30.7891 gap=1.2109 fenetre=0.6094/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.5819 spread=0.6094mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 12:55:03
Part fan PASS 12:55:05
Hotend fan PASS 12:55:07
Hotend heat 220°C PASS 12:55:10
Bed heat 60°C PASS 12:56:22
Cutter (feed+cut) PASS 12:57:57
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.7525 gap=1.2475 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 12:58:12
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 13:01:03
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=457.0091 gap=1.9909 (3/4) tap 5: pos=456.9847 gap=2.0153 fenetre=0.0244/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0244mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-30.1919 gap=1.8081 (3/4) tap 5: pos=-30.5819 gap=1.4181 fenetre=0.5850/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.1919 spread=0.5850mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,340.003 is z=415.152500 probe at 49.995,340.003 is z=415.270000 Tap drift (diff=0.1175mm) — reset probe at 49.995,340.003 is z=415.292500 Tap drift (diff=0.0225mm) — reset probe at 49.995,340.003 is z=415.280000 Tap drift (diff=0.0125mm) — reset probe at 49.995,340.003 is z=415.297500 Tap OK (diff=0.0050mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0050mm, stable 4/5) Tap OK (diff=0.0050mm, stable 5/5) VALIDATED: trigger_z=415.2975 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete!
Z tap repeatability PASS 13:05:39 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.8675, 486.1050, 486.1025, 486.1025, 486.1000, 486.1025, 486.1025, 486.0950, 486.1000, 486.1050, 486.1025, 486.1025, 486.1000, 486.1000, 486.1025
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,340.003 is z=0.835000 probe at 49.998,340.003 is z=0.850000 Tap drift (diff=0.0150mm) — reset probe at 49.998,340.003 is z=0.862500 Tap drift (diff=0.0125mm) — reset probe at 49.998,340.003 is z=0.857500 Tap OK (diff=0.0050mm, stable 2/5) probe at 49.998,340.003 is z=0.865000 Tap OK (diff=0.0075mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) probe at 49.998,340.003 is z=0.867500 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=0.8675 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete! probe at 49.998,340.003 is z=486.080000 probe at 49.998,340.003 is z=486.100000 Tap drift (diff=0.0200mm) — reset Tap OK (diff=0.0000mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 49.998,340.003 is z=486.105000 Tap OK (diff=0.0050mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=486.1050 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,340.003 is z=486.092500 Tap OK (diff=0.0075mm, stable 2/5) probe at 49.998,340.003 is z=486.102500 Tap OK (diff=0.0025mm, stable 3/5) VALIDATED: trigger_z=486.1025 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,340.003 is z=486.097500 Tap OK (diff=0.0025mm, stable 4/5) probe at 49.998,340.003 is z=486.095000 Tap OK (diff=0.0025mm, stable 2/5) VALIDATED: trigger_z=486.1000 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Tap OK (diff=0.0050mm, stable 3/5) probe at 49.998,340.003 is z=486.090000 VALIDATED: trigger_z=486.0950 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,340.003 is z=486.107500
Screws tilt PASS 13:06:21
probe: at 54.997,315.001 bed will contact at z=2.307500 probe: at 54.997,315.001 bed will contact at z=2.317500 probe: at 380.001,315.001 bed will contact at z=2.287500 probe: at 380.001,315.001 bed will contact at z=2.300000 probe: at 380.001,315.001 bed will contact at z=2.302500 probe: at 380.001,83.000 bed will contact at z=2.205000 probe: at 380.001,83.000 bed will contact at z=2.200000 probe: at 380.001,83.000 bed will contact at z=2.212500 probe: at 54.997,83.000 bed will contact at z=2.295000 probe: at 54.997,83.000 bed will contact at z=2.285000 probe: at 54.997,83.000 bed will contact at z=2.337500 Probe samples exceed tolerance. Retrying... probe: at 54.997,83.000 bed will contact at z=2.355000 probe: at 54.997,83.000 bed will contact at z=2.357500 probe: at 217.505,202.498 bed will contact at z=2.350000 probe: at 217.505,202.498 bed will contact at z=2.360000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=285.0, z=2.31750 front right screw : x=397.0, y=285.0, z=2.30000 : adjust CCW 00:02 rear right screw : x=397.0, y=53.0, z=2.20500 : adjust CCW 00:13 rear left screw : x=72.0, y=53.0, z=2.35500 : adjust CW 00:05 rear left screw : x=234.5, y=172.5, z=2.35000 : adjust CW 00:04