← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

540037001051353135323934

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 220V · 750W · SSR SSR10DA
QC pad (MAC) : 02813B23751D
Start : 2026-08-17T06:50:04.910294 · End : 2026-08-17T07:02:02.149204 · Duration : 717 s
Received (server) : 2026-08-17T07:04:47
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=750 ssr=SSR10DA lot=20260618 uid=9221AF

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 06:50:05
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=540037001051353135323934
Home X PASS 06:50:30
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.4234 gap=1.5766 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 06:51:05
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=-18.7769 gap=1.2231 (1/4) tap 3: pos=-18.7647 gap=1.2353 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-18.0091 gap=1.9909 fenetre=0.7800/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-18.3869 spread=0.7800mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 06:51:09
Part fan PASS 06:51:11
Hotend fan PASS 06:51:14
Hotend heat 220°C PASS 06:51:33
Bed heat 60°C PASS 06:51:33
Cutter (feed+cut) PASS 06:53:04
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-17.8019 gap=2.1981 (1/4) tap 3: pos=-18.1797 gap=1.8203 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-18.0091 gap=1.9909 fenetre=0.3778/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.3778mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 06:53:19
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 06:56:35
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-17.9847 gap=2.0153 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=411.065000 probe at 49.995,339.999 is z=411.050000 Tap drift (diff=0.0150mm) — reset probe at 49.995,339.999 is z=411.045000 Tap OK (diff=0.0050mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 49.995,339.999 is z=411.047500 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=411.0450 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete!
Z tap repeatability PASS 07:01:16 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=7.2000, 486.1000, 486.1025, 486.0975, 486.1025, 486.1000, 486.1000, 486.0975, 486.1025, 486.1000, 486.1000, 486.1050, 486.1025, 486.0875, 486.1200
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=323.677500 probe at 49.998,339.999 is z=7.205000 Tap drift (diff=316.4725mm) — reset probe at 49.998,339.999 is z=7.200000 Tap OK (diff=0.0050mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 49.998,339.999 is z=7.202500 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=7.2000 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete! probe at 49.998,339.999 is z=486.097500 Tap OK (diff=0.0000mm, stable 2/5) probe at 49.998,339.999 is z=486.100000 Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=486.1000 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Tap OK (diff=0.0025mm, stable 2/5) probe at 49.998,339.999 is z=486.102500 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) VALIDATED: trigger_z=486.1025 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) VALIDATED: trigger_z=486.0975 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,339.999 is z=490.217500 Tap drift (diff=4.1175mm) — reset probe at 49.998,339.999 is z=486.095000 probe at 49.998,339.999 is z=486.107500 Tap OK (diff=0.0050mm, stable 3/5) Tap OK (diff=0.0050mm, stable 4/5) probe at 49.998,339.999 is z=486.105000 VALIDATED: trigger_z=486.1050 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,339.999 is z=486.087500 Tap drift (diff=0.0125mm) — reset Tap drift (diff=0.0100mm) — reset probe at 49.998,339.999 is z=486.082500 Tap drift (diff=0.0150mm) — reset probe at 49.998,339.999 is z=489.080000 Tap drift (diff=2.9975mm) — reset
Screws tilt PASS 07:02:02
probe: at 54.997,328.001 bed will contact at z=2.592500 probe: at 54.997,328.001 bed will contact at z=2.567500 probe: at 54.997,328.001 bed will contact at z=2.600000 probe: at 380.001,328.001 bed will contact at z=2.540000 probe: at 380.001,328.001 bed will contact at z=2.555000 probe: at 380.001,328.001 bed will contact at z=2.542500 probe: at 380.001,101.996 bed will contact at z=2.442500 probe: at 380.001,101.996 bed will contact at z=2.437500 probe: at 380.001,101.996 bed will contact at z=2.427500 probe: at 54.997,101.996 bed will contact at z=2.495000 probe: at 54.997,101.996 bed will contact at z=2.480000 probe: at 54.997,101.996 bed will contact at z=2.467500 probe: at 217.505,214.498 bed will contact at z=2.547500 probe: at 217.505,214.498 bed will contact at z=2.500000 probe: at 217.505,214.498 bed will contact at z=2.565000 Probe samples exceed tolerance. Retrying... probe: at 217.505,214.498 bed will contact at z=2.512500 probe: at 217.505,214.498 bed will contact at z=2.577500 probe: at 217.505,214.498 bed will contact at z=2.505000 probe: at 217.505,214.498 bed will contact at z=2.572500 probe: at 217.505,214.498 bed will contact at z=2.515000 probe: at 217.505,214.498 bed will contact at z=2.517500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=2.59250 front right screw : x=397.0, y=298.0, z=2.54250 : adjust CCW 00:06 rear right screw : x=397.0, y=72.0, z=2.43750 : adjust CCW 00:19 rear left screw : x=72.0, y=72.0, z=2.48000 : adjust CCW 00:13 middle : x=234.5, y=184.5, z=2.51750 : adjust CCW 00:09