| Test | Result | Time | Details / log |
|---|---|---|---|
| MCU + firmware | PASS | 00:47:16 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=550;ssr=SSR10DA;lot=20260618;uid=2ACAAE
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=540047001051353135323934
|
| Home X | PASS | 00:47:41 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.2163 gap=1.7837 (chauffe, ignore)
tap 2: pos=457.3747 gap=1.6253 (1/4)
tap 3: pos=457.5941 gap=1.4059 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=457.1797 gap=1.8203 fenetre=0.5972/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=457.2863 spread=0.5972mm (tol=0.0500). Zero pose en butee=457.0000
|
| Home Y | PASS | 00:48:16 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-18.1797 gap=1.8203 (chauffe, ignore)
tap 2: pos=-18.7769 gap=1.2231 (1/4)
tap 3: pos=-18.7769 gap=1.2231 (2/4)
tap 4: pos=-18.5941 gap=1.4059 (3/4)
tap 5: pos=-18.1797 gap=1.8203 fenetre=0.5972/0.0500
YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-18.5819 spread=0.5972mm (tol=0.0500). Zero pose en butee=-18.0000
|
| Motherboard fan | PASS | 00:48:23 | |
| Part fan | PASS | 00:48:26 | |
| Hotend fan | PASS | 00:48:28 | |
| Hotend heat 220°C | PASS | 00:48:49 | |
| Bed heat 60°C | PASS | 00:49:26 | |
| Cutter (feed+cut) | PASS | 00:51:47 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.3869 gap=1.6131 (chauffe, ignore)
tap 2: pos=457.1797 gap=1.8203 (1/4)
tap 3: pos=457.5941 gap=1.4059 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=457.1797 gap=1.8203 fenetre=0.5972/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=457.2376 spread=0.5972mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore)
tap 2: pos=-17.9969 gap=2.0031 (1/4)
tap 3: pos=-17.9969 gap=2.0031 (2/4)
tap 4: pos=-17.9969 gap=2.0031 (3/4)
tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Extruder 'extruder1' now syncing with ''
Extruder 'extruder0' now syncing with 'extruder'
QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte)
QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120
Extruder 'extruder0' now syncing with ''
|
| YMS-2 feed to head | PASS | 00:52:10 |
Extruder 'extruder0' now syncing with ''
Extruder 'extruder1' now syncing with ''
Extruder 'extruder1' now syncing with 'extruder'
QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte)
QC E1_HEAD: filament a la tete apres 125mm + motion sensor YMS-2 OK
|
| Z tap home + Zmax | PASS | 00:55:03 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.3991 gap=1.6009 (chauffe, ignore)
tap 2: pos=457.5941 gap=1.4059 (1/4)
tap 3: pos=456.8019 gap=2.1981 (2/4)
tap 4: pos=457.3747 gap=1.6253 (3/4)
tap 5: pos=457.3991 gap=1.6009 fenetre=0.7922/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=457.2924 spread=0.7922mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore)
tap 2: pos=-18.1797 gap=1.8203 (1/4)
tap 3: pos=-18.5941 gap=1.4059 (2/4)
tap 4: pos=-18.1797 gap=1.8203 (3/4)
tap 5: pos=-18.5941 gap=1.4059 fenetre=0.4144/0.0500
YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-18.3869 spread=0.4144mm (tol=0.0500). Zero pose en butee=-18.0000
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.995,339.999 is z=385.800000
probe at 49.995,339.999 is z=385.832500
Tap drift (diff=0.0325mm) — reset
Tap OK (diff=0.0000mm, stable 2/5)
probe at 49.995,339.999 is z=385.835000
Tap OK (diff=0.0025mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 4/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=385.8350 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z calibration complete!
|
| Z tap repeatability | PASS | 01:00:00 |
OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.8950, 485.9075, 485.9000, 485.9075, 485.8975, 485.9025, 485.9025, 485.9075, 485.9025, 485.9000, 485.8975, 485.9025, 485.9025, 485.9025, 485.9000
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.998,339.999 is z=0.865000
probe at 49.998,339.999 is z=0.892500
Tap drift (diff=0.0275mm) — reset
Tap OK (diff=0.0000mm, stable 2/5)
Tap OK (diff=0.0000mm, stable 3/5)
probe at 49.998,339.999 is z=0.895000
Tap OK (diff=0.0025mm, stable 4/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=0.8950 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z calibration complete!
probe at 49.998,339.999 is z=485.880000
probe at 49.998,339.999 is z=485.902500
Tap drift (diff=0.0225mm) — reset
probe at 49.998,339.999 is z=485.907500
Tap OK (diff=0.0050mm, stable 2/5)
Tap OK (diff=0.0050mm, stable 3/5)
probe at 49.998,339.999 is z=485.905000
Tap OK (diff=0.0025mm, stable 5/5)
VALIDATED: trigger_z=485.9075 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 49.998,339.999 is z=485.875000
probe at 49.998,339.999 is z=485.900000
Tap drift (diff=0.0250mm) — reset
Tap OK (diff=0.0025mm, stable 2/5)
Tap OK (diff=0.0025mm, stable 3/5)
VALIDATED: trigger_z=485.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Tap OK (diff=0.0000mm, stable 4/5)
Tap OK (diff=0.0050mm, stable 5/5)
probe at 49.998,339.999 is z=485.872500
probe at 49.998,339.999 is z=485.897500
VALIDATED: trigger_z=485.8975 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 49.998,339.999 is z=485.877500
VALIDATED: trigger_z=485.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Tap drift (diff=0.0300mm) — reset
probe at 49.998,339.999 is z=485.870000
probe at 49.998,339.999 is z=485.867500
Tap drift (diff=0.0325mm) — reset
|
| Screws tilt | PASS | 01:00:46 |
probe: at 54.997,328.001 bed will contact at z=1.240000
probe: at 54.997,328.001 bed will contact at z=1.260000
probe: at 54.997,328.001 bed will contact at z=1.255000
probe: at 380.001,328.001 bed will contact at z=1.425000
probe: at 380.001,328.001 bed will contact at z=1.452500
probe: at 380.001,328.001 bed will contact at z=1.460000
probe: at 380.001,101.996 bed will contact at z=1.422500
probe: at 380.001,101.996 bed will contact at z=1.447500
probe: at 380.001,101.996 bed will contact at z=1.445000
probe: at 54.997,101.996 bed will contact at z=1.202500
probe: at 54.997,101.996 bed will contact at z=1.222500
probe: at 217.505,214.498 bed will contact at z=1.367500
probe: at 217.505,214.498 bed will contact at z=1.475000
Probe samples exceed tolerance. Retrying...
probe: at 217.505,214.498 bed will contact at z=1.412500
probe: at 217.505,214.498 bed will contact at z=1.427500
probe: at 217.505,214.498 bed will contact at z=1.492500
probe: at 217.505,214.498 bed will contact at z=1.440000
probe: at 217.505,214.498 bed will contact at z=1.435000
01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
front left screw (base) : x=72.0, y=298.0, z=1.25500
front right screw : x=397.0, y=298.0, z=1.45250 : adjust CW 00:24
rear right screw : x=397.0, y=72.0, z=1.44500 : adjust CW 00:23
rear left screw : x=72.0, y=72.0, z=1.22250 : adjust CCW 00:04
middle : x=234.5, y=184.5, z=1.43500 : adjust CW 00:22
|
| QC date | Result | QC pad (MAC) | Received (server) |
|---|---|---|---|
| 2026-10-21T00:47:16.119387 | PASS | 540047001051353135323934 | 2026-10-21T01:03:48 |
| 2026-10-20T04:42:36.008355 | PARTIAL | 540047001051353135323934 | 2026-10-28T00:58:35 |