← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

540047001051353135323934

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 110V · 550W · SSR SSR10DA
QC pad (MAC) : 0281E38DE8BE
Start : 2026-10-21T00:47:16.119387 · End : 2026-10-21T01:00:46.092021 · Duration : 809 s
Received (server) : 2026-10-21T01:03:48
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=110V bedw=550 ssr=SSR10DA lot=20260618 uid=2ACAAE

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 00:47:16
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=550;ssr=SSR10DA;lot=20260618;uid=2ACAAE [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=540047001051353135323934
Home X PASS 00:47:41
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.2163 gap=1.7837 (chauffe, ignore) tap 2: pos=457.3747 gap=1.6253 (1/4) tap 3: pos=457.5941 gap=1.4059 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=457.1797 gap=1.8203 fenetre=0.5972/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=457.2863 spread=0.5972mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 00:48:16
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.1797 gap=1.8203 (chauffe, ignore) tap 2: pos=-18.7769 gap=1.2231 (1/4) tap 3: pos=-18.7769 gap=1.2231 (2/4) tap 4: pos=-18.5941 gap=1.4059 (3/4) tap 5: pos=-18.1797 gap=1.8203 fenetre=0.5972/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-18.5819 spread=0.5972mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 00:48:23
Part fan PASS 00:48:26
Hotend fan PASS 00:48:28
Hotend heat 220°C PASS 00:48:49
Bed heat 60°C PASS 00:49:26
Cutter (feed+cut) PASS 00:51:47
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.3869 gap=1.6131 (chauffe, ignore) tap 2: pos=457.1797 gap=1.8203 (1/4) tap 3: pos=457.5941 gap=1.4059 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=457.1797 gap=1.8203 fenetre=0.5972/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=457.2376 spread=0.5972mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 00:52:10
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 125mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 00:55:03
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.3991 gap=1.6009 (chauffe, ignore) tap 2: pos=457.5941 gap=1.4059 (1/4) tap 3: pos=456.8019 gap=2.1981 (2/4) tap 4: pos=457.3747 gap=1.6253 (3/4) tap 5: pos=457.3991 gap=1.6009 fenetre=0.7922/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=457.2924 spread=0.7922mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-18.1797 gap=1.8203 (1/4) tap 3: pos=-18.5941 gap=1.4059 (2/4) tap 4: pos=-18.1797 gap=1.8203 (3/4) tap 5: pos=-18.5941 gap=1.4059 fenetre=0.4144/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-18.3869 spread=0.4144mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=385.800000 probe at 49.995,339.999 is z=385.832500 Tap drift (diff=0.0325mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 49.995,339.999 is z=385.835000 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=385.8350 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete!
Z tap repeatability PASS 01:00:00 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.8950, 485.9075, 485.9000, 485.9075, 485.8975, 485.9025, 485.9025, 485.9075, 485.9025, 485.9000, 485.8975, 485.9025, 485.9025, 485.9025, 485.9000
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=0.865000 probe at 49.998,339.999 is z=0.892500 Tap drift (diff=0.0275mm) — reset Tap OK (diff=0.0000mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 49.998,339.999 is z=0.895000 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=0.8950 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete! probe at 49.998,339.999 is z=485.880000 probe at 49.998,339.999 is z=485.902500 Tap drift (diff=0.0225mm) — reset probe at 49.998,339.999 is z=485.907500 Tap OK (diff=0.0050mm, stable 2/5) Tap OK (diff=0.0050mm, stable 3/5) probe at 49.998,339.999 is z=485.905000 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=485.9075 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 49.998,339.999 is z=485.875000 probe at 49.998,339.999 is z=485.900000 Tap drift (diff=0.0250mm) — reset Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0025mm, stable 3/5) VALIDATED: trigger_z=485.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0050mm, stable 5/5) probe at 49.998,339.999 is z=485.872500 probe at 49.998,339.999 is z=485.897500 VALIDATED: trigger_z=485.8975 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 49.998,339.999 is z=485.877500 VALIDATED: trigger_z=485.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Tap drift (diff=0.0300mm) — reset probe at 49.998,339.999 is z=485.870000 probe at 49.998,339.999 is z=485.867500 Tap drift (diff=0.0325mm) — reset
Screws tilt PASS 01:00:46
probe: at 54.997,328.001 bed will contact at z=1.240000 probe: at 54.997,328.001 bed will contact at z=1.260000 probe: at 54.997,328.001 bed will contact at z=1.255000 probe: at 380.001,328.001 bed will contact at z=1.425000 probe: at 380.001,328.001 bed will contact at z=1.452500 probe: at 380.001,328.001 bed will contact at z=1.460000 probe: at 380.001,101.996 bed will contact at z=1.422500 probe: at 380.001,101.996 bed will contact at z=1.447500 probe: at 380.001,101.996 bed will contact at z=1.445000 probe: at 54.997,101.996 bed will contact at z=1.202500 probe: at 54.997,101.996 bed will contact at z=1.222500 probe: at 217.505,214.498 bed will contact at z=1.367500 probe: at 217.505,214.498 bed will contact at z=1.475000 Probe samples exceed tolerance. Retrying... probe: at 217.505,214.498 bed will contact at z=1.412500 probe: at 217.505,214.498 bed will contact at z=1.427500 probe: at 217.505,214.498 bed will contact at z=1.492500 probe: at 217.505,214.498 bed will contact at z=1.440000 probe: at 217.505,214.498 bed will contact at z=1.435000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=1.25500 front right screw : x=397.0, y=298.0, z=1.45250 : adjust CW 00:24 rear right screw : x=397.0, y=72.0, z=1.44500 : adjust CW 00:23 rear left screw : x=72.0, y=72.0, z=1.22250 : adjust CCW 00:04 middle : x=234.5, y=184.5, z=1.43500 : adjust CW 00:22

History — 2 reports for this machine

QC dateResultQC pad (MAC)Received (server)
2026-10-21T00:47:16.119387 PASS 540047001051353135323934 2026-10-21T01:03:48
2026-10-20T04:42:36.008355 PARTIAL 540047001051353135323934 2026-10-28T00:58:35