← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

54005D001051353135323934

PASS Grade A Grade B
Model : C335 · Batch : 20260618
Heated bed : 110V · 500W · SSR SSR10DA
QC pad (MAC) : 0281E38DE8BE
Start : 2026-07-28T00:54:33.010286 · End : 2026-07-28T01:05:46.274843 · Duration : 673 s
Received (server) : 2026-07-28T01:07:35
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C335 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=110V bedw=500 ssr=SSR10DA lot=20260618 uid=B3D7BD

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 00:54:33
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=500;ssr=SSR10DA;lot=20260618;uid=B3D7BD [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=54005D001051353135323934
Home X PASS 00:55:00
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1 rejete: cible atteinte sans buter (gap=0.8453) tap 2: pos=356.8019 gap=2.1981 (chauffe, ignore) tap 3: pos=356.9969 gap=2.0031 (1/4) tap 4: pos=357.1919 gap=1.8081 (2/4) tap 5: pos=356.9969 gap=2.0031 (3/4) tap 6: pos=356.8019 gap=2.1981 fenetre=0.3900/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (1 rejetes) -> moyenne=356.9969 spread=0.3900mm (tol=0.0500). Zero pose en butee=357.0000
Home Y PASS 00:55:36
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.5819 gap=1.4181 (chauffe, ignore) tap 2: pos=-30.7769 gap=1.2231 (1/4) tap 3: pos=-30.7769 gap=1.2231 (2/4) tap 4: pos=-30.7769 gap=1.2231 (3/4) tap 5: pos=-30.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-30.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 00:55:42
Part fan PASS 00:55:45
Hotend fan PASS 00:55:47
Hotend heat 220°C PASS 00:55:49
Bed heat 60°C PASS 00:55:51
Cutter (feed+cut) PASS 00:57:26
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.9597 gap=1.0403 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=357.1919 gap=1.8081 (2/4) tap 4: pos=356.8019 gap=2.1981 (3/4) tap 5: pos=357.1919 gap=1.8081 fenetre=0.3900/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=357.0456 spread=0.3900mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=-30.7769 gap=1.2231 (1/4) tap 3: pos=-30.7769 gap=1.2231 (2/4) tap 4: pos=-30.7769 gap=1.2231 (3/4) tap 5: pos=-30.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-30.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 00:57:40
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 01:00:30
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7525 gap=1.2475 (chauffe, ignore) tap 2: pos=-30.7769 gap=1.2231 (1/4) tap 3: pos=-30.7769 gap=1.2231 (2/4) tap 4: pos=-30.7769 gap=1.2231 (3/4) tap 5: pos=-30.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-30.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.996,275.995 is z=285.832500 probe at 65.996,275.995 is z=285.837500 Tap OK (diff=0.0050mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=285.8375 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete!
Z tap repeatability PASS 01:05:15 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.9475, 385.9000, 385.8975, 385.9000, 385.9025, 385.8975, 385.9000, 385.9000, 385.9000, 385.9000, 385.9000, 385.9000, 385.9000, 385.9000, 385.9000
Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.999,275.995 is z=395.737500 probe at 65.999,275.995 is z=398.467500 Tap rejete (vibration chassis, z=398.4675 > max-z_hop) -> pas de remontee, on poursuit la descente (1) probe at 65.999,275.995 is z=398.257500 Tap rejete (vibration chassis, z=398.2575 > max-z_hop) -> pas de remontee, on poursuit la descente (2) probe at 65.999,275.995 is z=398.067500 Tap rejete (vibration chassis, z=398.0675 > max-z_hop) -> pas de remontee, on poursuit la descente (3) probe at 65.999,275.995 is z=397.877500 Tap rejete (vibration chassis, z=397.8775 > max-z_hop) -> pas de remontee, on poursuit la descente (4) probe at 65.999,275.995 is z=397.707500 Tap rejete (vibration chassis, z=397.7075 > max-z_hop) -> pas de remontee, on poursuit la descente (5) probe at 65.999,275.995 is z=397.522500 Tap rejete (vibration chassis, z=397.5225 > max-z_hop) -> pas de remontee, on poursuit la descente (6) probe at 65.999,275.995 is z=397.352500 Tap rejete (vibration chassis, z=397.3525 > max-z_hop) -> pas de remontee, on poursuit la descente (7) probe at 65.999,275.995 is z=397.190000 Tap rejete (vibration chassis, z=397.1900 > max-z_hop) -> pas de remontee, on poursuit la descente (8) probe at 65.999,275.995 is z=397.027500 Tap rejete (vibration chassis, z=397.0275 > max-z_hop) -> pas de remontee, on poursuit la descente (9) probe at 65.999,275.995 is z=396.865000 probe at 65.999,275.995 is z=399.592500 Tap rejete (vibration chassis, z=399.5925 > max-z_hop) -> pas de remontee, on poursuit la descente (10) probe at 65.999,275.995 is z=0.960000 probe at 65.999,275.995 is z=3.755000 Tap drift (diff=2.7950mm) — reset probe at 65.999,275.995 is z=0.955000 Tap drift (diff=2.8000mm) — reset probe at 65.999,275.995 is z=0.952500 Tap drift (diff=2.8025mm) — reset probe at 65.999,275.995 is z=3.752500 probe at 65.999,275.995 is z=2.942500 Tap drift (diff=0.8100mm) — reset probe at 65.999,275.995 is z=0.945000 Tap drift (diff=1.9975mm) — reset probe at 65.999,275.995 is z=0.947500 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5)
Screws tilt PASS 01:05:46
probe: at 67.000,271.004 bed will contact at z=1.412500 probe: at 67.000,271.004 bed will contact at z=1.407500 probe: at 67.000,271.004 bed will contact at z=1.405000 probe: at 267.996,271.004 bed will contact at z=1.367500 probe: at 267.996,271.004 bed will contact at z=1.347500 probe: at 267.996,271.004 bed will contact at z=1.352500 probe: at 267.996,71.995 bed will contact at z=1.395000 probe: at 267.996,71.995 bed will contact at z=1.405000 probe: at 267.996,71.995 bed will contact at z=1.377500 probe: at 67.000,71.995 bed will contact at z=1.385000 probe: at 67.000,71.995 bed will contact at z=1.377500 probe: at 67.000,71.995 bed will contact at z=1.365000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=84.0, y=241.0, z=1.40750 front right screw : x=285.0, y=241.0, z=1.35250 : adjust CCW 00:07 rear right screw : x=285.0, y=42.0, z=1.39500 : adjust CCW 00:01 rear left screw : x=84.0, y=42.0, z=1.37750 : adjust CCW 00:04