← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

540061001051353135323934

FAIL Grade A Grade B
Model : C235 · Batch : 20260616
Heated bed : 220V · 300W · SSR SSR10DA
QC pad (MAC) : 02813B23751D
Start : 2026-07-01T05:34:53.406601 · End : 2026-07-01T05:41:18.321838 · Duration : 384 s
Received (server) : 2026-07-01T05:36:44
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C235 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=300 ssr=SSR10DA lot=20260616 uid=61C229

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 05:34:53
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C235;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=300;ssr=SSR10DA;lot=20260616;uid=61C229 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=540061001051353135323934
Home X PASS 05:35:16
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=255.8019 gap=2.1981 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.1950/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=255.9481 spread=0.1950mm (tol=0.0500). Zero pose en butee=256.0000
Home Y PASS 05:35:47
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.3991 gap=1.6009 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 05:35:54
Part fan PASS 05:35:56
Hotend fan PASS 05:35:59
Hotend heat 220°C PASS 05:36:13
Bed heat 60°C PASS 05:36:13
Cutter (feed+cut) PASS 05:37:42
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.4234 gap=1.5766 (chauffe, ignore) tap 2: pos=256.1797 gap=1.8203 (1/4) tap 3: pos=255.8141 gap=2.1859 (2/4) tap 4: pos=256.1797 gap=1.8203 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.3656/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=256.0426 spread=0.3656mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 05:37:57
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax FAIL 05:40:58 Timeout: no result from printer
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=256.1797 gap=1.8203 (1/4) tap 3: pos=256.5941 gap=1.4059 (2/4) tap 4: pos=256.1797 gap=1.8203 (3/4) tap 5: pos=256.5941 gap=1.4059 fenetre=0.4144/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=256.3869 spread=0.4144mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1797 gap=1.8203 (chauffe, ignore) tap 2: pos=-30.0091 gap=1.9909 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0122/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9999 spread=0.0122mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 31.003,211.998 is z=179.527500 probe at 31.003,211.998 is z=179.502500 Tap drift (diff=0.0250mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 31.003,211.998 is z=179.517500 Tap drift (diff=0.0100mm) — reset probe at 31.003,211.998 is z=179.505000 Tap drift (diff=0.0125mm) — reset probe at 31.003,211.998 is z=179.525000 Tap drift (diff=0.0200mm) — reset probe at 31.003,211.998 is z=179.530000 Tap OK (diff=0.0050mm, stable 2/5) probe at 31.003,211.998 is z=179.522500 Tap OK (diff=0.0075mm, stable 3/5) probe at 31.003,211.998 is z=179.450000 Tap drift (diff=0.0725mm) — reset probe at 31.003,211.998 is z=179.457500 Tap OK (diff=0.0075mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0075mm, stable 4/5) probe at 31.003,211.998 is z=179.407500
Z tap repeatability PENDING
probe at 31.003,211.998 is z=179.455000 Tap OK (diff=0.0025mm, stable 3/5) probe at 31.003,211.998 is z=179.415000 Tap drift (diff=0.0400mm) — reset probe at 31.003,211.998 is z=179.465000 Tap drift (diff=0.0500mm) — reset probe at 31.003,211.998 is z=179.502500 Tap drift (diff=0.0375mm) — reset probe at 31.003,211.998 is z=179.507500 Tap OK (diff=0.0050mm, stable 2/5) Tap drift (diff=0.0425mm) — reset probe at 31.003,211.998 is z=179.457500 probe at 31.003,211.998 is z=179.460000 Tap OK (diff=0.0025mm, stable 2/5) probe at 31.003,211.998 is z=179.417500 probe at 31.003,211.998 is z=179.375000 Tap drift (diff=0.0825mm) — reset probe at 31.003,211.998 is z=179.385000 Tap OK (diff=0.0100mm, stable 2/5)
Screws tilt PENDING

History — 4 reports for this machine

QC dateResultQC pad (MAC)Received (server)
2026-07-01T05:34:53.406601 FAIL 540061001051353135323934 2026-07-01T05:36:44
2026-06-29T01:20:52.721119 FAIL 540061001051353135323934 2026-06-29T01:26:24
2026-06-22T15:21:55.509827 PASS 540061001051353135323934 2026-08-04T06:47:39
2026-06-22T15:19:00.468256 PARTIAL 540061001051353135323934 2026-08-04T06:47:34