← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

55003E000D51353234323830

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 220V · 750W · SSR SSR10DA
QC pad (MAC) : 0281E38DE8BE
Start : 2026-07-30T02:42:51.353671 · End : 2026-07-30T02:54:57.981130 · Duration : 726 s
Received (server) : 2026-09-11T08:30:59
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=750 ssr=SSR10DA lot=20260618 uid=9221AF

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 02:42:51
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=55003E000D51353234323830
Home X PASS 02:43:17
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.8019 gap=2.1981 (2/4) tap 4: pos=457.1919 gap=1.8081 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.3900/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.3900mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 02:43:52
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.1797 gap=1.8203 (chauffe, ignore) tap 2: pos=-18.7769 gap=1.2231 (1/4) tap 3: pos=-18.7769 gap=1.2231 (2/4) tap 4: pos=-18.7769 gap=1.2231 (3/4) tap 5: pos=-18.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 02:43:58
Part fan PASS 02:44:00
Hotend fan PASS 02:44:02
Hotend heat 220°C PASS 02:44:05
Bed heat 60°C PASS 02:44:23
Cutter (feed+cut) PASS 02:45:50
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.3869 gap=1.6131 (chauffe, ignore) tap 2: pos=457.1919 gap=1.8081 (1/4) tap 3: pos=456.8019 gap=2.1981 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.3900/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.3900mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=-18.7769 gap=1.2231 (1/4) tap 3: pos=-18.7769 gap=1.2231 (2/4) tap 4: pos=-18.7769 gap=1.2231 (3/4) tap 5: pos=-18.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 02:46:05
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 02:49:32
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.3869 gap=1.6131 (chauffe, ignore) tap 2: pos=457.1919 gap=1.8081 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.8019 gap=2.1981 fenetre=0.3900/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.3900mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=-18.7769 gap=1.2231 (1/4) tap 3: pos=-18.5819 gap=1.4181 (2/4) tap 4: pos=-18.1919 gap=1.8081 (3/4) tap 5: pos=-18.7769 gap=1.2231 fenetre=0.5850/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-18.5819 spread=0.5850mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=495.745000 probe at 49.995,339.999 is z=409.632500 Tap drift (diff=86.1125mm) — reset probe at 49.995,339.999 is z=409.640000 Tap OK (diff=0.0075mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 49.995,339.999 is z=409.642500 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=409.6425 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete!
Z tap repeatability PASS 02:54:15 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.8825, 485.9100, 485.9025, 485.9050, 485.9000, 485.9025, 485.9025, 485.9025, 485.9025, 485.8975, 485.9025, 485.9100, 485.8925, 485.9100, 485.9000
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=495.742500 probe at 49.998,339.999 is z=0.860000 Tap drift (diff=494.8825mm) — reset probe at 49.998,339.999 is z=0.865000 Tap OK (diff=0.0050mm, stable 2/5) probe at 49.998,339.999 is z=0.877500 Tap drift (diff=0.0125mm) — reset probe at 49.998,339.999 is z=0.880000 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 49.998,339.999 is z=0.882500 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=0.8825 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete! probe at 49.998,339.999 is z=485.902500 probe at 49.998,339.999 is z=485.907500 probe at 49.998,339.999 is z=485.910000 VALIDATED: trigger_z=485.9100 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 49.998,339.999 is z=485.897500 Tap OK (diff=0.0000mm, stable 4/5) VALIDATED: trigger_z=485.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 49.998,339.999 is z=485.900000 probe at 49.998,339.999 is z=485.905000 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=485.9050 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) VALIDATED: trigger_z=485.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 49.998,339.999 is z=485.895000 Tap OK (diff=0.0025mm, stable 3/5) VALIDATED: trigger_z=485.8975 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Tap OK (diff=0.0075mm, stable 5/5) probe at 49.998,339.999 is z=485.887500 probe at 49.998,339.999 is z=485.890000 probe at 49.998,339.999 is z=485.892500 Tap OK (diff=0.0075mm, stable 4/5) VALIDATED: trigger_z=485.8925 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Tap drift (diff=0.0100mm) — reset
Screws tilt PASS 02:54:57
probe: at 54.997,328.001 bed will contact at z=1.750000 probe: at 54.997,328.001 bed will contact at z=1.755000 probe: at 380.001,328.001 bed will contact at z=1.782500 probe: at 380.001,328.001 bed will contact at z=1.797500 probe: at 380.001,101.996 bed will contact at z=1.650000 probe: at 380.001,101.996 bed will contact at z=1.682500 probe: at 380.001,101.996 bed will contact at z=1.705000 Probe samples exceed tolerance. Retrying... probe: at 380.001,101.996 bed will contact at z=1.702500 probe: at 380.001,101.996 bed will contact at z=1.692500 probe: at 54.997,101.996 bed will contact at z=1.685000 probe: at 217.505,214.498 bed will contact at z=1.792500 probe: at 217.505,214.498 bed will contact at z=1.777500 probe: at 217.505,214.498 bed will contact at z=1.787500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=1.75000 front right screw : x=397.0, y=298.0, z=1.78250 : adjust CW 00:04 rear right screw : x=397.0, y=72.0, z=1.69250 : adjust CCW 00:07 rear left screw : x=72.0, y=72.0, z=1.68500 : adjust CCW 00:08 middle : x=234.5, y=184.5, z=1.78750 : adjust CW 00:05