| Test | Result | Time | Details / log |
|---|---|---|---|
| MCU + firmware | PASS | 04:33:00 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=550;ssr=SSR10DA;lot=20260618;uid=2ACAAE
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=550041001051353135323934
|
| Home X | PASS | 04:33:25 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.2284 gap=1.7716 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=457.1919 gap=1.8081 fenetre=0.1950/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=457.0456 spread=0.1950mm (tol=0.0500). Zero pose en butee=457.0000
|
| Home Y | PASS | 04:34:09 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1 rejete: aucun contact sur 7.0mm (No trigger on probe after full movement)
tap 2 rejete: aucun contact sur 7.0mm (No trigger on probe after full movement)
YUMI_SENSORLESS_HOME Y: home de base suspect (pas de contact) -> re-home de recuperation 1/2
tap 3: pos=-30.7647 gap=1.2353 (chauffe, ignore)
tap 4: pos=-29.9969 gap=2.0031 (1/4)
tap 5: pos=-29.9969 gap=2.0031 (2/4)
tap 6: pos=-29.9969 gap=2.0031 (3/4)
tap 7: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (2 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
|
| Motherboard fan | PASS | 04:35:50 | |
| Part fan | PASS | 04:35:52 | |
| Hotend fan | PASS | 04:35:55 | |
| Hotend heat 220°C | PASS | 04:35:55 | |
| Bed heat 60°C | PASS | 04:35:55 | |
| Cutter (feed+cut) | PASS | 04:37:46 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.2163 gap=1.7837 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-30.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=-29.9969 gap=2.0031 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Extruder 'extruder1' now syncing with ''
Extruder 'extruder0' now syncing with 'extruder'
QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte)
QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120
Extruder 'extruder0' now syncing with ''
|
| YMS-2 feed to head | PASS | 04:38:01 |
Extruder 'extruder0' now syncing with ''
Extruder 'extruder1' now syncing with ''
Extruder 'extruder1' now syncing with 'extruder'
QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte)
QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
|
| Z tap home + Zmax | PASS | 04:41:01 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.3747 gap=1.6253 (chauffe, ignore)
tap 2: pos=457.1919 gap=1.8081 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.1950/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=457.0456 spread=0.1950mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-30.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=-29.9969 gap=2.0031 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.995,340.003 is z=481.642500
probe at 49.995,340.003 is z=406.122500
Tap drift (diff=75.5200mm) — reset
probe at 49.995,340.003 is z=406.125000
Tap OK (diff=0.0025mm, stable 2/5)
probe at 49.995,340.003 is z=406.127500
Tap OK (diff=0.0025mm, stable 3/5)
probe at 49.995,340.003 is z=406.130000
Tap OK (diff=0.0025mm, stable 4/5)
probe at 49.995,340.003 is z=406.135000
Tap OK (diff=0.0050mm, stable 5/5)
VALIDATED: trigger_z=406.1350 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z calibration complete!
|
| Z tap repeatability | PASS | 04:45:41 |
OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.1275, 486.1050, 486.1075, 486.1075, 486.1050, 486.1000, 486.1050, 486.0975, 486.1050, 486.1000, 486.1000, 486.1050, 486.0975, 486.1050, 486.0975
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.998,340.003 is z=495.642500
probe at 49.998,340.003 is z=498.280000
Tap rejete (vibration chassis, z=498.2800 > max-z_hop) -> pas de remontee, on poursuit la descente (1)
probe at 49.998,340.003 is z=1.112500
probe at 49.998,340.003 is z=1.122500
Tap drift (diff=0.0100mm) — reset
probe at 49.998,340.003 is z=1.125000
Tap OK (diff=0.0025mm, stable 2/5)
probe at 49.998,340.003 is z=1.120000
Tap OK (diff=0.0050mm, stable 3/5)
probe at 49.998,340.003 is z=1.127500
Tap OK (diff=0.0075mm, stable 4/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=1.1275 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z calibration complete!
probe at 49.998,340.003 is z=486.102500
Tap OK (diff=0.0000mm, stable 2/5)
Tap OK (diff=0.0000mm, stable 3/5)
probe at 49.998,340.003 is z=486.105000
Tap OK (diff=0.0025mm, stable 4/5)
VALIDATED: trigger_z=486.1050 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Tap OK (diff=0.0000mm, stable 4/5)
probe at 49.998,340.003 is z=486.107500
Tap OK (diff=0.0025mm, stable 5/5)
VALIDATED: trigger_z=486.1075 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
probe at 49.998,340.003 is z=493.205000
probe at 49.998,340.003 is z=490.530000
Tap drift (diff=2.6750mm) — reset
Tap drift (diff=4.4275mm) — reset
Tap OK (diff=0.0025mm, stable 3/5)
probe at 49.998,340.003 is z=486.097500
Tap OK (diff=0.0050mm, stable 2/5)
probe at 49.998,340.003 is z=486.100000
VALIDATED: trigger_z=486.1000 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
probe at 49.998,340.003 is z=486.095000
Tap OK (diff=0.0050mm, stable 4/5)
Tap OK (diff=0.0050mm, stable 5/5)
|
| Screws tilt | PASS | 04:46:32 |
probe: at 54.997,315.001 bed will contact at z=1.605000
probe: at 54.997,315.001 bed will contact at z=1.602500
probe: at 54.997,315.001 bed will contact at z=1.607500
probe: at 380.001,315.001 bed will contact at z=1.545000
probe: at 380.001,315.001 bed will contact at z=1.532500
probe: at 380.001,83.000 bed will contact at z=1.525000
probe: at 380.001,83.000 bed will contact at z=1.522500
probe: at 380.001,83.000 bed will contact at z=1.520000
probe: at 54.997,83.000 bed will contact at z=1.650000
probe: at 54.997,83.000 bed will contact at z=1.660000
probe: at 217.505,202.498 bed will contact at z=1.652500
probe: at 217.505,202.498 bed will contact at z=1.667500
probe: at 217.505,202.498 bed will contact at z=1.725000
Probe samples exceed tolerance. Retrying...
probe: at 217.505,202.498 bed will contact at z=1.665000
probe: at 217.505,202.498 bed will contact at z=1.702500
probe: at 217.505,202.498 bed will contact at z=1.635000
probe: at 217.505,202.498 bed will contact at z=1.770000
probe: at 217.505,202.498 bed will contact at z=1.677500
probe: at 217.505,202.498 bed will contact at z=1.712500
probe: at 217.505,202.498 bed will contact at z=1.680000
probe: at 217.505,202.498 bed will contact at z=1.710000
probe: at 217.505,202.498 bed will contact at z=1.675000
01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
front left screw (base) : x=72.0, y=285.0, z=1.60500
front right screw : x=397.0, y=285.0, z=1.54500 : adjust CCW 00:07
rear right screw : x=397.0, y=53.0, z=1.52250 : adjust CCW 00:10
rear left screw : x=72.0, y=53.0, z=1.65000 : adjust CW 00:05
rear left screw : x=234.5, y=172.5, z=1.68000 : adjust CW 00:09
|