← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

560040001051353135323934

PASS Grade A Grade B
Model : C335 · Batch : 20260618
Heated bed : 220V · 500W · SSR SSR10DA
QC pad (MAC) : 0281605119E6
Start : 2026-07-17T08:29:34.934401 · End : 2026-07-17T08:41:37.734279 · Duration : 722 s
Received (server) : 2026-07-17T08:44:05
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C335 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=500 ssr=SSR10DA lot=20260618 uid=36C6E9

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 08:29:35
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=500;ssr=SSR10DA;lot=20260618;uid=36C6E9 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=560040001051353135323934
Home X PASS 08:30:00
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.4234 gap=1.5766 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000
Home Y PASS 08:30:31
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.0091 gap=1.9909 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 08:30:37
Part fan PASS 08:30:39
Hotend fan PASS 08:30:42
Hotend heat 220°C PASS 08:30:53
Bed heat 60°C PASS 08:31:19
Cutter (feed+cut) PASS 08:32:46
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 08:33:01
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 08:35:48
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.996,275.995 is z=285.687500 probe at 65.996,275.995 is z=285.692500 Tap OK (diff=0.0050mm, stable 2/5) Tap OK (diff=0.0050mm, stable 3/5) probe at 65.996,275.995 is z=285.685000 Tap OK (diff=0.0025mm, stable 4/5) probe at 65.996,275.995 is z=285.690000 Tap OK (diff=0.0050mm, stable 5/5) VALIDATED: trigger_z=285.6900 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete!
Z tap repeatability PASS 08:41:03 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.9225, 385.9050, 385.9100, 385.9075, 385.9325, 385.9000, 385.9000, 385.9025, 385.9075, 385.8950, 385.8925, 385.9075, 385.8950, 385.9050, 385.9050
Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.999,275.995 is z=0.782500 probe at 65.999,275.995 is z=0.910000 Tap drift (diff=0.1275mm) — reset probe at 65.999,275.995 is z=0.905000 Tap OK (diff=0.0050mm, stable 2/5) Tap OK (diff=0.0050mm, stable 3/5) probe at 65.999,275.995 is z=0.915000 Tap OK (diff=0.0050mm, stable 4/5) probe at 65.999,275.995 is z=0.922500 Tap OK (diff=0.0075mm, stable 5/5) VALIDATED: trigger_z=0.9225 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete! probe at 65.999,275.995 is z=385.915000 probe at 65.999,275.995 is z=385.905000 Tap OK (diff=0.0100mm, stable 2/5) probe at 65.999,275.995 is z=385.902500 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=385.9050 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 65.999,275.995 is z=385.912500 probe at 65.999,275.995 is z=385.907500 probe at 65.999,275.995 is z=385.900000 Tap OK (diff=0.0075mm, stable 3/5) Tap OK (diff=0.0075mm, stable 4/5) probe at 65.999,275.995 is z=385.910000 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=385.9100 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 65.999,275.995 is z=385.897500 Tap OK (diff=0.0075mm, stable 2/5) Tap OK (diff=0.0000mm, stable 4/5) VALIDATED: trigger_z=385.9075 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 65.999,275.995 is z=385.895000 Tap OK (diff=0.0025mm, stable 2/5) Tap drift (diff=0.0125mm) — reset probe at 65.999,275.995 is z=385.920000 probe at 65.999,275.995 is z=385.925000
Screws tilt PASS 08:41:37
probe: at 67.000,271.004 bed will contact at z=1.665000 probe: at 67.000,271.004 bed will contact at z=1.890000 Probe samples exceed tolerance. Retrying... probe: at 67.000,271.004 bed will contact at z=1.912500 probe: at 67.000,271.004 bed will contact at z=1.897500 probe: at 67.000,271.004 bed will contact at z=1.910000 probe: at 267.996,271.004 bed will contact at z=1.752500 probe: at 267.996,271.004 bed will contact at z=1.762500 probe: at 267.996,71.995 bed will contact at z=1.742500 probe: at 267.996,71.995 bed will contact at z=1.737500 probe: at 267.996,71.995 bed will contact at z=1.745000 probe: at 67.000,71.995 bed will contact at z=1.945000 probe: at 67.000,71.995 bed will contact at z=2.020000 probe: at 67.000,71.995 bed will contact at z=2.005000 probe: at 67.000,71.995 bed will contact at z=2.030000 probe: at 67.000,71.995 bed will contact at z=2.035000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=84.0, y=241.0, z=1.91000 front right screw : x=285.0, y=241.0, z=1.76250 : adjust CCW 00:18 rear right screw : x=285.0, y=42.0, z=1.74250 : adjust CCW 00:20 rear left screw : x=84.0, y=42.0, z=2.03000 : adjust CW 00:14