| Test | Result | Time | Details / log |
|---|---|---|---|
| MCU + firmware | PASS | 02:39:43 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=500;ssr=SSR10DA;lot=20260618;uid=36C6E9
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=560042001051353135323934
|
| Home X | PASS | 02:40:11 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=357.5941 gap=1.4059 (chauffe, ignore)
tap 2: pos=357.7769 gap=1.2231 (1/4)
tap 3: pos=357.7769 gap=1.2231 (2/4)
tap 4: pos=357.7769 gap=1.2231 (3/4)
tap 5: pos=357.7769 gap=1.2231 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=357.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000
|
| Home Y | PASS | 02:40:48 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore)
tap 2: pos=-29.9969 gap=2.0031 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
|
| Motherboard fan | PASS | 02:40:53 | |
| Part fan | PASS | 02:40:55 | |
| Hotend fan | PASS | 02:40:58 | |
| Hotend heat 220°C | PASS | 02:40:58 | |
| Bed heat 60°C | PASS | 02:40:58 | |
| Cutter (feed+cut) | PASS | 02:42:37 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=357.5941 gap=1.4059 (chauffe, ignore)
tap 2: pos=356.9969 gap=2.0031 (1/4)
tap 3: pos=357.7769 gap=1.2231 (2/4)
tap 4: pos=357.7769 gap=1.2231 (3/4)
tap 5: pos=357.5941 gap=1.4059 fenetre=0.7800/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=357.5362 spread=0.7800mm (tol=0.0500). Zero pose en butee=357.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore)
tap 2: pos=-29.9969 gap=2.0031 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Extruder 'extruder1' now syncing with ''
Extruder 'extruder0' now syncing with 'extruder'
QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte)
QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120
Extruder 'extruder0' now syncing with ''
|
| YMS-2 feed to head | PASS | 02:42:52 |
Extruder 'extruder0' now syncing with ''
Extruder 'extruder1' now syncing with ''
Extruder 'extruder1' now syncing with 'extruder'
QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte)
QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
|
| Z tap home + Zmax | PASS | 02:45:58 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=357.4112 gap=1.5888 (chauffe, ignore)
tap 2: pos=357.1797 gap=1.8203 (1/4)
tap 3: pos=356.9969 gap=2.0031 (2/4)
tap 4: pos=356.9969 gap=2.0031 (3/4)
tap 5: pos=357.5941 gap=1.4059 fenetre=0.5972/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=357.1919 spread=0.5972mm (tol=0.0500). Zero pose en butee=357.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore)
tap 2: pos=-29.9969 gap=2.0031 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Moving to tap point X=66.0 Y=276.0...
Probing with pressure switch...
probe at 65.996,275.995 is z=315.735000
probe at 65.996,275.995 is z=315.820000
Tap drift (diff=0.0850mm) — reset
probe at 65.996,275.995 is z=315.822500
Tap OK (diff=0.0025mm, stable 2/5)
probe at 65.996,275.995 is z=315.842500
Tap drift (diff=0.0200mm) — reset
probe at 65.996,275.995 is z=315.850000
Tap OK (diff=0.0075mm, stable 2/5)
probe at 65.996,275.995 is z=315.832500
Tap drift (diff=0.0175mm) — reset
probe at 65.996,275.995 is z=315.845000
Tap drift (diff=0.0125mm) — reset
Tap OK (diff=0.0000mm, stable 2/5)
Tap OK (diff=0.0000mm, stable 3/5)
probe at 65.996,275.995 is z=315.847500
Tap OK (diff=0.0025mm, stable 4/5)
probe at 65.996,275.995 is z=315.830000
Tap OK (diff=0.0050mm, stable 3/5)
probe at 65.996,275.995 is z=315.852500
Tap OK (diff=0.0075mm, stable 4/5)
|
| Z tap repeatability | PASS | 02:51:12 |
OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.8750, 385.9300, 385.9025, 385.9025, 385.9000, 385.9000, 385.9025, 385.9000, 385.9000, 385.9025, 385.9200, 385.9000, 385.9000, 385.9000, 385.9000
Moving to tap point X=66.0 Y=276.0...
Probing with pressure switch...
probe at 65.999,275.995 is z=0.775000
probe at 65.999,275.995 is z=0.872500
Tap drift (diff=0.0975mm) — reset
Tap OK (diff=0.0000mm, stable 2/5)
probe at 65.999,275.995 is z=0.875000
Tap OK (diff=0.0025mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 4/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=0.8750 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0)
Z calibration complete!
probe at 65.999,275.995 is z=385.880000
probe at 65.999,275.995 is z=385.932500
Tap drift (diff=0.0525mm) — reset
probe at 65.999,275.995 is z=385.930000
VALIDATED: trigger_z=385.9300 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 65.999,275.995 is z=385.860000
probe at 65.999,275.995 is z=385.902500
Tap drift (diff=0.0425mm) — reset
probe at 65.999,275.995 is z=385.905000
Tap OK (diff=0.0025mm, stable 2/5)
Tap OK (diff=0.0000mm, stable 3/5)
Tap OK (diff=0.0025mm, stable 5/5)
VALIDATED: trigger_z=385.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 65.999,275.995 is z=385.857500
probe at 65.999,275.995 is z=385.900000
probe at 65.999,275.995 is z=385.852500
Tap drift (diff=0.0475mm) — reset
VALIDATED: trigger_z=385.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 65.999,275.995 is z=385.897500
probe at 65.999,275.995 is z=385.855000
Tap drift (diff=0.0450mm) — reset
Tap OK (diff=0.0025mm, stable 4/5)
probe at 65.999,275.995 is z=385.895000
Tap OK (diff=0.0050mm, stable 3/5)
probe at 65.999,275.995 is z=385.920000
Tap drift (diff=0.0250mm) — reset
Tap drift (diff=0.0200mm) — reset
|
| Screws tilt | PASS | 02:51:51 |
probe: at 67.000,271.004 bed will contact at z=2.450000
probe: at 67.000,271.004 bed will contact at z=2.500000
Probe samples exceed tolerance. Retrying...
probe: at 67.000,271.004 bed will contact at z=2.480000
probe: at 67.000,271.004 bed will contact at z=2.510000
probe: at 267.996,271.004 bed will contact at z=2.810000
probe: at 267.996,271.004 bed will contact at z=2.857500
probe: at 267.996,271.004 bed will contact at z=2.877500
probe: at 267.996,271.004 bed will contact at z=2.852500
probe: at 267.996,271.004 bed will contact at z=2.880000
probe: at 267.996,271.004 bed will contact at z=2.897500
probe: at 267.996,71.995 bed will contact at z=2.882500
probe: at 267.996,71.995 bed will contact at z=2.945000
probe: at 267.996,71.995 bed will contact at z=2.892500
probe: at 267.996,71.995 bed will contact at z=2.910000
probe: at 267.996,71.995 bed will contact at z=2.925000
probe: at 67.000,71.995 bed will contact at z=2.395000
probe: at 67.000,71.995 bed will contact at z=2.457500
probe: at 67.000,71.995 bed will contact at z=2.442500
probe: at 67.000,71.995 bed will contact at z=2.450000
probe: at 67.000,71.995 bed will contact at z=2.435000
01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
front left screw (base) : x=84.0, y=241.0, z=2.50000
front right screw : x=285.0, y=241.0, z=2.88000 : adjust CW 00:46
rear right screw : x=285.0, y=42.0, z=2.91000 : adjust CW 00:49
rear left screw : x=84.0, y=42.0, z=2.44250 : adjust CCW 00:07
|
| QC date | Result | QC pad (MAC) | Received (server) |
|---|---|---|---|
| 2026-07-14T02:39:43.551851 | PASS | 560042001051353135323934 | 2026-07-17T06:38:12 |
| 2026-07-14T02:29:52.300138 | FAIL | 560042001051353135323934 | 2026-07-17T06:38:11 |