← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

560044000D51353234323830

PASS Grade A Grade B
Model : C335 · Batch : 20260618
Heated bed : 220V · 500W · SSR SSR10DA
QC pad (MAC) : 0281EEB2BA2E
Start : 2026-07-14T05:57:55.962253 · End : 2026-07-14T06:09:59.334528 · Duration : 723 s
Received (server) : 2026-07-17T06:38:13
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C335 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=500 ssr=SSR10DA lot=20260618 uid=36C6E9

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 05:57:56
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=500;ssr=SSR10DA;lot=20260618;uid=36C6E9 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=560044000D51353234323830
Home X PASS 05:58:23
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=357.0091 gap=1.9909 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.8019 gap=2.1981 fenetre=0.2072/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=356.9512 spread=0.2072mm (tol=0.0500). Zero pose en butee=357.0000
Home Y PASS 05:58:59
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1797 gap=1.8203 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 05:59:06
Part fan PASS 05:59:09
Hotend fan PASS 05:59:12
Hotend heat 220°C PASS 05:59:14
Bed heat 60°C PASS 05:59:14
Cutter (feed+cut) PASS 06:00:45
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=357.1797 gap=1.8203 (1/4) tap 3: pos=356.8141 gap=2.1859 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=357.1797 gap=1.8203 fenetre=0.3656/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=357.0426 spread=0.3656mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 06:00:59
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 06:03:55
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=356.8019 gap=2.1981 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=357.1919 gap=1.8081 fenetre=0.3900/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.3900mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.996,275.995 is z=305.682500 probe at 65.996,275.995 is z=305.812500 Tap drift (diff=0.1300mm) — reset probe at 65.996,275.995 is z=308.570000 Tap drift (diff=2.7575mm) — reset probe at 65.996,275.995 is z=311.322500 Tap drift (diff=2.7525mm) — reset probe at 65.996,275.995 is z=305.800000 Tap drift (diff=5.5225mm) — reset probe at 65.996,275.995 is z=305.807500 Tap OK (diff=0.0075mm, stable 2/5) probe at 65.996,275.995 is z=308.560000 Tap drift (diff=2.7600mm) — reset probe at 65.996,275.995 is z=308.557500 Tap drift (diff=2.7500mm) — reset probe at 65.996,275.995 is z=311.280000 Tap drift (diff=2.7225mm) — reset probe at 65.996,275.995 is z=305.797500 Tap drift (diff=5.4825mm) — reset probe at 65.996,275.995 is z=305.805000 Tap OK (diff=0.0025mm, stable 3/5)
Z tap repeatability PASS 06:09:25 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.9650, 385.8900, 385.9050, 385.8925, 385.9050, 385.9100, 385.9000, 385.8975, 385.9000, 385.9050, 385.8975, 385.9025, 385.8925, 385.9000, 385.9025
Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.999,275.995 is z=0.807500 probe at 65.999,275.995 is z=0.965000 Tap drift (diff=0.1575mm) — reset probe at 65.999,275.995 is z=0.945000 Tap drift (diff=0.0200mm) — reset probe at 65.999,275.995 is z=0.962500 Tap drift (diff=0.0175mm) — reset probe at 65.999,275.995 is z=0.947500 Tap drift (diff=0.0150mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 65.999,275.995 is z=0.950000 Tap OK (diff=0.0025mm, stable 3/5) probe at 65.999,275.995 is z=0.970000 Tap OK (diff=0.0050mm, stable 2/5) Tap drift (diff=0.0225mm) — reset probe at 65.999,275.995 is z=0.960000 Tap drift (diff=0.0125mm) — reset Tap OK (diff=0.0025mm, stable 2/5) probe at 65.999,275.995 is z=0.955000 Tap OK (diff=0.0075mm, stable 3/5) Tap OK (diff=0.0075mm, stable 4/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=0.9650 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete! probe at 65.999,275.995 is z=385.860000 probe at 65.999,275.995 is z=385.885000 Tap drift (diff=0.0250mm) — reset probe at 65.999,275.995 is z=388.635000 Tap drift (diff=2.7500mm) — reset probe at 65.999,275.995 is z=391.357500 Tap drift (diff=2.7225mm) — reset probe at 65.999,275.995 is z=385.867500 Tap drift (diff=5.4900mm) — reset probe at 65.999,275.995 is z=385.890000 probe at 65.999,275.995 is z=385.902500 probe at 65.999,275.995 is z=385.905000 probe at 65.999,275.995 is z=385.887500
Screws tilt PASS 06:09:59
probe: at 67.000,271.004 bed will contact at z=0.512500 probe: at 67.000,271.004 bed will contact at z=0.582500 Probe samples exceed tolerance. Retrying... probe: at 67.000,271.004 bed will contact at z=0.585000 probe: at 67.000,271.004 bed will contact at z=0.590000 probe: at 67.000,271.004 bed will contact at z=0.572500 probe: at 267.996,271.004 bed will contact at z=0.550000 probe: at 267.996,271.004 bed will contact at z=0.562500 probe: at 267.996,271.004 bed will contact at z=0.572500 probe: at 267.996,71.995 bed will contact at z=0.630000 probe: at 267.996,71.995 bed will contact at z=0.647500 probe: at 267.996,71.995 bed will contact at z=0.655000 probe: at 67.000,71.995 bed will contact at z=0.572500 probe: at 67.000,71.995 bed will contact at z=0.605000 probe: at 67.000,71.995 bed will contact at z=0.595000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=84.0, y=241.0, z=0.58500 front right screw : x=285.0, y=241.0, z=0.56250 : adjust CCW 00:03 rear right screw : x=285.0, y=42.0, z=0.64750 : adjust CW 00:08 rear left screw : x=84.0, y=42.0, z=0.59500 : adjust CW 00:01