| Test | Result | Time | Details / log |
|---|---|---|---|
| MCU + firmware | PASS | 05:57:56 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=500;ssr=SSR10DA;lot=20260618;uid=36C6E9
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=560044000D51353234323830
|
| Home X | PASS | 05:58:23 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=357.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=357.0091 gap=1.9909 (1/4)
tap 3: pos=356.9969 gap=2.0031 (2/4)
tap 4: pos=356.9969 gap=2.0031 (3/4)
tap 5: pos=356.8019 gap=2.1981 fenetre=0.2072/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=356.9512 spread=0.2072mm (tol=0.0500). Zero pose en butee=357.0000
|
| Home Y | PASS | 05:58:59 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-30.1797 gap=1.8203 (chauffe, ignore)
tap 2: pos=-29.9969 gap=2.0031 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
|
| Motherboard fan | PASS | 05:59:06 | |
| Part fan | PASS | 05:59:09 | |
| Hotend fan | PASS | 05:59:12 | |
| Hotend heat 220°C | PASS | 05:59:14 | |
| Bed heat 60°C | PASS | 05:59:14 | |
| Cutter (feed+cut) | PASS | 06:00:45 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=357.5697 gap=1.4303 (chauffe, ignore)
tap 2: pos=357.1797 gap=1.8203 (1/4)
tap 3: pos=356.8141 gap=2.1859 (2/4)
tap 4: pos=356.9969 gap=2.0031 (3/4)
tap 5: pos=357.1797 gap=1.8203 fenetre=0.3656/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=357.0426 spread=0.3656mm (tol=0.0500). Zero pose en butee=357.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-30.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=-29.9969 gap=2.0031 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Extruder 'extruder1' now syncing with ''
Extruder 'extruder0' now syncing with 'extruder'
QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte)
QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120
Extruder 'extruder0' now syncing with ''
|
| YMS-2 feed to head | PASS | 06:00:59 |
Extruder 'extruder0' now syncing with ''
Extruder 'extruder1' now syncing with ''
Extruder 'extruder1' now syncing with 'extruder'
QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte)
QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
|
| Z tap home + Zmax | PASS | 06:03:55 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=357.7769 gap=1.2231 (chauffe, ignore)
tap 2: pos=356.8019 gap=2.1981 (1/4)
tap 3: pos=356.9969 gap=2.0031 (2/4)
tap 4: pos=356.9969 gap=2.0031 (3/4)
tap 5: pos=357.1919 gap=1.8081 fenetre=0.3900/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.3900mm (tol=0.0500). Zero pose en butee=357.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-30.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=-29.9969 gap=2.0031 (1/4)
tap 3: pos=-29.9969 gap=2.0031 (2/4)
tap 4: pos=-29.9969 gap=2.0031 (3/4)
tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Moving to tap point X=66.0 Y=276.0...
Probing with pressure switch...
probe at 65.996,275.995 is z=305.682500
probe at 65.996,275.995 is z=305.812500
Tap drift (diff=0.1300mm) — reset
probe at 65.996,275.995 is z=308.570000
Tap drift (diff=2.7575mm) — reset
probe at 65.996,275.995 is z=311.322500
Tap drift (diff=2.7525mm) — reset
probe at 65.996,275.995 is z=305.800000
Tap drift (diff=5.5225mm) — reset
probe at 65.996,275.995 is z=305.807500
Tap OK (diff=0.0075mm, stable 2/5)
probe at 65.996,275.995 is z=308.560000
Tap drift (diff=2.7600mm) — reset
probe at 65.996,275.995 is z=308.557500
Tap drift (diff=2.7500mm) — reset
probe at 65.996,275.995 is z=311.280000
Tap drift (diff=2.7225mm) — reset
probe at 65.996,275.995 is z=305.797500
Tap drift (diff=5.4825mm) — reset
probe at 65.996,275.995 is z=305.805000
Tap OK (diff=0.0025mm, stable 3/5)
|
| Z tap repeatability | PASS | 06:09:25 |
OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.9650, 385.8900, 385.9050, 385.8925, 385.9050, 385.9100, 385.9000, 385.8975, 385.9000, 385.9050, 385.8975, 385.9025, 385.8925, 385.9000, 385.9025
Moving to tap point X=66.0 Y=276.0...
Probing with pressure switch...
probe at 65.999,275.995 is z=0.807500
probe at 65.999,275.995 is z=0.965000
Tap drift (diff=0.1575mm) — reset
probe at 65.999,275.995 is z=0.945000
Tap drift (diff=0.0200mm) — reset
probe at 65.999,275.995 is z=0.962500
Tap drift (diff=0.0175mm) — reset
probe at 65.999,275.995 is z=0.947500
Tap drift (diff=0.0150mm) — reset
Tap OK (diff=0.0000mm, stable 2/5)
probe at 65.999,275.995 is z=0.950000
Tap OK (diff=0.0025mm, stable 3/5)
probe at 65.999,275.995 is z=0.970000
Tap OK (diff=0.0050mm, stable 2/5)
Tap drift (diff=0.0225mm) — reset
probe at 65.999,275.995 is z=0.960000
Tap drift (diff=0.0125mm) — reset
Tap OK (diff=0.0025mm, stable 2/5)
probe at 65.999,275.995 is z=0.955000
Tap OK (diff=0.0075mm, stable 3/5)
Tap OK (diff=0.0075mm, stable 4/5)
Tap OK (diff=0.0025mm, stable 5/5)
VALIDATED: trigger_z=0.9650 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0)
Z calibration complete!
probe at 65.999,275.995 is z=385.860000
probe at 65.999,275.995 is z=385.885000
Tap drift (diff=0.0250mm) — reset
probe at 65.999,275.995 is z=388.635000
Tap drift (diff=2.7500mm) — reset
probe at 65.999,275.995 is z=391.357500
Tap drift (diff=2.7225mm) — reset
probe at 65.999,275.995 is z=385.867500
Tap drift (diff=5.4900mm) — reset
probe at 65.999,275.995 is z=385.890000
probe at 65.999,275.995 is z=385.902500
probe at 65.999,275.995 is z=385.905000
probe at 65.999,275.995 is z=385.887500
|
| Screws tilt | PASS | 06:09:59 |
probe: at 67.000,271.004 bed will contact at z=0.512500
probe: at 67.000,271.004 bed will contact at z=0.582500
Probe samples exceed tolerance. Retrying...
probe: at 67.000,271.004 bed will contact at z=0.585000
probe: at 67.000,271.004 bed will contact at z=0.590000
probe: at 67.000,271.004 bed will contact at z=0.572500
probe: at 267.996,271.004 bed will contact at z=0.550000
probe: at 267.996,271.004 bed will contact at z=0.562500
probe: at 267.996,271.004 bed will contact at z=0.572500
probe: at 267.996,71.995 bed will contact at z=0.630000
probe: at 267.996,71.995 bed will contact at z=0.647500
probe: at 267.996,71.995 bed will contact at z=0.655000
probe: at 67.000,71.995 bed will contact at z=0.572500
probe: at 67.000,71.995 bed will contact at z=0.605000
probe: at 67.000,71.995 bed will contact at z=0.595000
01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
front left screw (base) : x=84.0, y=241.0, z=0.58500
front right screw : x=285.0, y=241.0, z=0.56250 : adjust CCW 00:03
rear right screw : x=285.0, y=42.0, z=0.64750 : adjust CW 00:08
rear left screw : x=84.0, y=42.0, z=0.59500 : adjust CW 00:01
|
Moves this report to the trash — you can restore it from /trash.