← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

560047000D51353234323830

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 220V · 750W · SSR SSR10DA
QC pad (MAC) : 0281AE52CB5F
Start : 2026-08-08T08:34:12.646391 · End : 2026-08-08T08:47:00.297588 · Duration : 767 s
Received (server) : 2026-08-10T00:57:27
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=750 ssr=SSR10DA lot=20260618 uid=9221AF

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 08:34:12
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=560047000D51353234323830
Home X PASS 08:34:39
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 08:35:14
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-17.9847 gap=2.0153 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 08:35:18
Part fan PASS 08:35:21
Hotend fan PASS 08:35:23
Hotend heat 220°C PASS 08:35:33
Bed heat 60°C PASS 08:36:05
Cutter (feed+cut) PASS 08:37:40
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 08:37:55
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 08:41:23
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5575 gap=1.4425 (chauffe, ignore) tap 2: pos=457.0091 gap=1.9909 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0122/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9999 spread=0.0122mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=472.475000 probe at 49.995,339.999 is z=413.967500 Tap drift (diff=58.5075mm) — reset probe at 49.995,339.999 is z=413.965000 Tap OK (diff=0.0025mm, stable 2/5) probe at 49.995,339.999 is z=413.985000 Tap drift (diff=0.0200mm) — reset probe at 49.995,339.999 is z=415.847500 Tap drift (diff=1.8625mm) — reset Tap drift (diff=1.8800mm) — reset probe at 49.995,339.999 is z=413.970000 probe at 49.995,339.999 is z=413.982500 Tap drift (diff=0.0125mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 49.995,339.999 is z=413.977500 Tap OK (diff=0.0050mm, stable 3/5) probe at 49.995,339.999 is z=413.975000 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0075mm, stable 5/5) VALIDATED: trigger_z=413.9825 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z tap repeatability PASS 08:46:18 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.1525, 486.1025, 486.1050, 486.1225, 486.0975, 486.1075, 486.1000, 486.1000, 486.1025, 486.1000, 486.1000, 486.0975, 486.1025, 486.0975, 486.1025
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=1.122500 probe at 49.998,339.999 is z=1.142500 Tap drift (diff=0.0200mm) — reset probe at 49.998,339.999 is z=1.150000 Tap OK (diff=0.0075mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) probe at 49.998,339.999 is z=1.152500 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=1.1525 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete! probe at 49.998,339.999 is z=495.745000 probe at 49.998,339.999 is z=486.097500 Tap drift (diff=9.6475mm) — reset probe at 49.998,339.999 is z=486.102500 Tap OK (diff=0.0050mm, stable 2/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=486.1025 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,339.999 is z=495.752500 Tap drift (diff=9.6550mm) — reset probe at 49.998,339.999 is z=486.105000 Tap OK (diff=0.0025mm, stable 3/5) VALIDATED: trigger_z=486.1050 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,339.999 is z=486.100000 probe at 49.998,339.999 is z=486.115000 Tap drift (diff=0.0100mm) — reset probe at 49.998,339.999 is z=486.120000 probe at 49.998,339.999 is z=486.117500 probe at 49.998,339.999 is z=486.107500 Tap OK (diff=0.0100mm, stable 4/5) Tap OK (diff=0.0025mm, stable 2/5) probe at 49.998,339.999 is z=486.122500 Tap OK (diff=0.0050mm, stable 4/5) VALIDATED: trigger_z=486.1225 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,339.999 is z=486.080000 probe at 49.998,339.999 is z=486.090000 Tap OK (diff=0.0050mm, stable 3/5)
Screws tilt PASS 08:47:00
probe: at 54.997,328.001 bed will contact at z=1.352500 probe: at 54.997,328.001 bed will contact at z=1.360000 probe: at 54.997,328.001 bed will contact at z=1.362500 probe: at 380.001,328.001 bed will contact at z=1.465000 probe: at 380.001,328.001 bed will contact at z=1.422500 probe: at 380.001,328.001 bed will contact at z=1.470000 probe: at 380.001,101.996 bed will contact at z=1.487500 probe: at 380.001,101.996 bed will contact at z=1.430000 Probe samples exceed tolerance. Retrying... probe: at 380.001,101.996 bed will contact at z=1.457500 probe: at 380.001,101.996 bed will contact at z=1.467500 probe: at 380.001,101.996 bed will contact at z=1.452500 probe: at 54.997,101.996 bed will contact at z=1.392500 probe: at 54.997,101.996 bed will contact at z=1.390000 probe: at 54.997,101.996 bed will contact at z=1.405000 probe: at 217.505,214.498 bed will contact at z=1.465000 probe: at 217.505,214.498 bed will contact at z=1.467500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=1.36000 front right screw : x=397.0, y=298.0, z=1.46500 : adjust CW 00:13 rear right screw : x=397.0, y=72.0, z=1.45750 : adjust CW 00:12 rear left screw : x=72.0, y=72.0, z=1.39250 : adjust CW 00:04 middle : x=234.5, y=184.5, z=1.46500 : adjust CW 00:13