SmartPi 1
SmartPi 2

560058001051353135323934

PASS Grade A Grade B
Model : C335 · Batch : 20260618
Heated bed : 110V · 500W · SSR SSR10DA
QC pad (MAC) : 0281EB778EE3
Start : 2026-07-30T04:40:23.206181 · End : 2026-07-30T04:52:22.600210 · Duration : 719 s
Received (server) : 2026-07-31T01:13:43
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C335 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=110V bedw=500 ssr=SSR10DA lot=20260618 uid=B3D7BD

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 04:40:23
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=500;ssr=SSR10DA;lot=20260618;uid=B3D7BD [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=560058001051353135323934
Home X PASS 04:40:49
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000
Home Y PASS 04:41:21
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 04:41:35
Part fan PASS 04:41:42
Hotend fan PASS 04:41:45
Hotend heat 220°C PASS 04:41:45
Bed heat 60°C PASS 04:41:45
Cutter (feed+cut) PASS 04:43:09
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 04:43:23
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 04:46:08
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.4234 gap=1.5766 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.996,275.995 is z=308.640000 probe at 65.996,275.995 is z=308.727500 Tap drift (diff=0.0875mm) — reset probe at 65.996,275.995 is z=308.745000 Tap drift (diff=0.0175mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 65.996,275.995 is z=308.747500 Tap OK (diff=0.0025mm, stable 3/5) probe at 65.996,275.995 is z=308.752500 Tap OK (diff=0.0050mm, stable 4/5) probe at 65.996,275.995 is z=308.755000 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=308.7550 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete!
Z tap repeatability PASS 04:51:46 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.9700, 385.9125, 385.9275, 385.9025, 385.9000, 385.9025, 385.9000, 385.9025, 385.9050, 385.8975, 385.9025, 385.9050, 385.8950, 385.9050, 385.8975
Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.999,275.995 is z=97.707500 probe at 65.999,275.995 is z=0.857500 Tap drift (diff=96.8500mm) — reset probe at 65.999,275.995 is z=0.947500 Tap drift (diff=0.0900mm) — reset probe at 65.999,275.995 is z=0.967500 Tap drift (diff=0.0200mm) — reset probe at 65.999,275.995 is z=0.970000 Tap OK (diff=0.0025mm, stable 2/5) probe at 65.999,275.995 is z=0.972500 Tap OK (diff=0.0025mm, stable 3/5) probe at 65.999,275.995 is z=0.975000 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0050mm, stable 5/5) VALIDATED: trigger_z=0.9700 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete! probe at 65.999,275.995 is z=385.845000 probe at 65.999,275.995 is z=385.907500 Tap drift (diff=0.0625mm) — reset probe at 65.999,275.995 is z=385.912500 Tap OK (diff=0.0050mm, stable 2/5) probe at 65.999,275.995 is z=385.910000 Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=385.9125 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 65.999,275.995 is z=385.847500 probe at 65.999,275.995 is z=385.900000 Tap drift (diff=0.0525mm) — reset Tap OK (diff=0.0075mm, stable 2/5) Tap OK (diff=0.0000mm, stable 4/5) probe at 65.999,275.995 is z=385.927500 Tap drift (diff=0.0175mm) — reset probe at 65.999,275.995 is z=385.915000 Tap drift (diff=0.0125mm) — reset probe at 65.999,275.995 is z=387.257500 Tap drift (diff=1.3475mm) — reset Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10) Tap drift (diff=1.3425mm) — reset
Screws tilt PASS 04:52:22
probe: at 67.000,271.004 bed will contact at z=2.135000 probe: at 67.000,271.004 bed will contact at z=2.210000 Probe samples exceed tolerance. Retrying... probe: at 67.000,271.004 bed will contact at z=2.215000 probe: at 67.000,271.004 bed will contact at z=2.225000 probe: at 67.000,271.004 bed will contact at z=2.212500 probe: at 267.996,271.004 bed will contact at z=2.187500 probe: at 267.996,271.004 bed will contact at z=2.237500 probe: at 267.996,271.004 bed will contact at z=2.232500 probe: at 267.996,271.004 bed will contact at z=2.240000 probe: at 267.996,71.995 bed will contact at z=2.242500 probe: at 267.996,71.995 bed will contact at z=2.280000 probe: at 267.996,71.995 bed will contact at z=2.290000 probe: at 67.000,71.995 bed will contact at z=2.157500 probe: at 67.000,71.995 bed will contact at z=2.227500 probe: at 67.000,71.995 bed will contact at z=2.242500 probe: at 67.000,71.995 bed will contact at z=2.230000 probe: at 67.000,71.995 bed will contact at z=2.225000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=84.0, y=241.0, z=2.21500 front right screw : x=285.0, y=241.0, z=2.23750 : adjust CW 00:03 rear right screw : x=285.0, y=42.0, z=2.28000 : adjust CW 00:08 rear left screw : x=84.0, y=42.0, z=2.23000 : adjust CW 00:02