← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

570041001051353135323934

PASS Grade A Grade B
Model : C235 · Batch : 20260616
Heated bed : 220V · 300W · SSR SSR10DA
QC pad (MAC) : 0281DE6A3114
Start : 2026-06-30T06:40:38.800303 · End : 2026-06-30T06:51:50.053918 · Duration : 671 s
Received (server) : 2026-06-30T07:12:54
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C235 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=300 ssr=SSR10DA lot=20260616 uid=61C229

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 06:40:38
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C235;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=300;ssr=SSR10DA;lot=20260616;uid=61C229 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=570041001051353135323934
Home X PASS 06:41:00
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=256.0091 gap=1.9909 (2/4) tap 4: pos=255.9847 gap=2.0153 (3/4) tap 5: pos=256.0091 gap=1.9909 fenetre=0.0244/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9999 spread=0.0244mm (tol=0.0500). Zero pose en butee=256.0000
Home Y PASS 06:41:34
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 06:42:34
Part fan PASS 06:42:39
Hotend fan PASS 06:42:42
Hotend heat 220°C PASS 06:42:42
Bed heat 60°C PASS 06:42:42
Cutter (feed+cut) PASS 06:44:08
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=256.0091 gap=1.9909 (1/4) tap 3: pos=255.9847 gap=2.0153 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0244/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0244mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.3869 gap=1.6131 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.8019 gap=2.1981 fenetre=0.1950/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-29.9481 spread=0.1950mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 06:44:23
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 06:46:57
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=256.0091 gap=1.9909 (2/4) tap 4: pos=255.9847 gap=2.0153 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0244/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0244mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.3869 gap=1.6131 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 31.003,211.998 is z=265.947500 probe at 31.003,211.998 is z=175.940000 Tap drift (diff=90.0075mm) — reset probe at 31.003,211.998 is z=175.967500 Tap drift (diff=0.0275mm) — reset probe at 31.003,211.998 is z=175.970000 Tap OK (diff=0.0025mm, stable 2/5) probe at 31.003,211.998 is z=175.972500 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=175.9725 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete!
Z tap repeatability PASS 06:51:21 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.9050, 255.9025, 255.9050, 255.8975, 255.9025, 255.8975, 255.9000, 255.8975, 255.9025, 255.9000, 255.9000, 255.9000, 255.9000, 255.8975, 255.9050
Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 30.994,211.998 is z=265.887500 probe at 30.994,211.998 is z=72.987500 Tap drift (diff=192.9000mm) — reset probe at 30.994,211.998 is z=0.867500 Tap drift (diff=72.1200mm) — reset probe at 30.994,211.998 is z=0.902500 Tap drift (diff=0.0350mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 30.994,211.998 is z=0.905000 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=0.9050 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete! probe at 30.994,211.998 is z=255.895000 probe at 30.994,211.998 is z=255.902500 Tap OK (diff=0.0075mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) VALIDATED: trigger_z=255.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=258.450000 Tap drift (diff=2.5475mm) — reset probe at 30.994,211.998 is z=255.905000 probe at 30.994,211.998 is z=258.570000 Tap drift (diff=2.6650mm) — reset Tap drift (diff=2.6675mm) — reset probe at 30.994,211.998 is z=256.215000 Tap drift (diff=0.3100mm) — reset Tap drift (diff=0.3125mm) — reset Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=255.9050 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.897500 Tap OK (diff=0.0025mm, stable 2/5) VALIDATED: trigger_z=255.8975 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=265.227500 probe at 30.994,211.998 is z=267.177500 Tap rejete (vibration chassis, z=267.1775 > max-z_hop) -> pas de remontee, on poursuit la descente (1)
Screws tilt PASS 06:51:50
probe: at 32.495,205.497 bed will contact at z=1.142500 probe: at 32.495,205.497 bed will contact at z=1.162500 probe: at 32.495,205.497 bed will contact at z=1.150000 probe: at 206.996,205.497 bed will contact at z=1.847500 probe: at 206.996,205.497 bed will contact at z=1.900000 Probe samples exceed tolerance. Retrying... probe: at 206.996,205.497 bed will contact at z=1.910000 probe: at 206.996,205.497 bed will contact at z=1.885000 probe: at 206.996,205.497 bed will contact at z=1.887500 probe: at 206.996,31.995 bed will contact at z=1.732500 probe: at 206.996,31.995 bed will contact at z=1.747500 probe: at 206.996,31.995 bed will contact at z=1.727500 probe: at 32.495,31.995 bed will contact at z=1.317500 probe: at 32.495,31.995 bed will contact at z=1.330000 probe: at 32.495,31.995 bed will contact at z=1.327500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=49.5, y=175.5, z=1.15000 front right screw : x=224.0, y=175.5, z=1.88750 : adjust CW 01:29 rear right screw : x=224.0, y=2.0, z=1.73250 : adjust CW 01:10 rear left screw : x=49.5, y=2.0, z=1.32750 : adjust CW 00:21