| Test | Result | Time | Details / log |
|---|---|---|---|
| MCU + firmware | PASS | 04:29:46 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=570045001051353135323934
|
| Home X | PASS | 04:30:12 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.5819 gap=1.4181 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
|
| Home Y | PASS | 04:30:46 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-18.7769 gap=1.2231 (chauffe, ignore)
tap 2: pos=-17.9969 gap=2.0031 (1/4)
tap 3: pos=-17.9969 gap=2.0031 (2/4)
tap 4: pos=-17.9847 gap=2.0153 (3/4)
tap 5: pos=-18.0091 gap=1.9909 fenetre=0.0244/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0244mm (tol=0.0500). Zero pose en butee=-18.0000
|
| Motherboard fan | PASS | 04:30:55 | |
| Part fan | PASS | 04:30:57 | |
| Hotend fan | PASS | 04:30:59 | |
| Hotend heat 220°C | PASS | 04:31:11 | |
| Bed heat 60°C | PASS | 04:31:21 | |
| Cutter (feed+cut) | PASS | 04:33:20 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.3869 gap=1.6131 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=457.1797 gap=1.8203 (2/4)
tap 4: pos=456.9969 gap=2.0031 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.1828/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=457.0426 spread=0.1828mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-18.7769 gap=1.2231 (chauffe, ignore)
tap 2: pos=-17.9969 gap=2.0031 (1/4)
tap 3: pos=-17.9847 gap=2.0153 (2/4)
tap 4: pos=-18.0091 gap=1.9909 (3/4)
tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0244/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0244mm (tol=0.0500). Zero pose en butee=-18.0000
Extruder 'extruder1' now syncing with ''
Extruder 'extruder0' now syncing with 'extruder'
QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte)
QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120
Extruder 'extruder0' now syncing with ''
|
| YMS-2 feed to head | PASS | 04:33:42 |
Extruder 'extruder0' now syncing with ''
Extruder 'extruder1' now syncing with ''
Extruder 'extruder1' now syncing with 'extruder'
QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte)
QC E1_HEAD: filament a la tete apres 125mm + motion sensor YMS-2 OK
|
| Z tap home + Zmax | PASS | 04:36:11 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.5697 gap=1.4303 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=457.1797 gap=1.8203 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.1828/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=457.0426 spread=0.1828mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-18.7769 gap=1.2231 (chauffe, ignore)
tap 2: pos=-17.9969 gap=2.0031 (1/4)
tap 3: pos=-17.9847 gap=2.0153 (2/4)
tap 4: pos=-18.0091 gap=1.9909 (3/4)
tap 5: pos=-17.9847 gap=2.0153 fenetre=0.0244/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9938 spread=0.0244mm (tol=0.0500). Zero pose en butee=-18.0000
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.995,339.999 is z=439.727500
probe at 49.995,339.999 is z=385.585000
Tap drift (diff=54.1425mm) — reset
probe at 49.995,339.999 is z=385.600000
Tap drift (diff=0.0150mm) — reset
Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10)
probe at 49.995,339.999 is z=385.602500
Tap OK (diff=0.0025mm, stable 2/5)
probe at 49.995,339.999 is z=385.605000
Tap OK (diff=0.0025mm, stable 3/5)
probe at 49.995,339.999 is z=385.610000
Tap OK (diff=0.0050mm, stable 4/5)
probe at 49.995,339.999 is z=385.617500
Tap OK (diff=0.0075mm, stable 5/5)
VALIDATED: trigger_z=385.6175 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z calibration complete!
|
| Z tap repeatability | PASS | 04:41:11 |
OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.0375, 485.9000, 485.9025, 485.9000, 485.9025, 485.9000, 485.9075, 485.9200, 485.8925, 485.9025, 485.9050, 485.9025, 485.9000, 485.9000, 485.9000
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.998,339.999 is z=138.320000
probe at 49.998,339.999 is z=131.480000
Tap drift (diff=6.8400mm) — reset
probe at 49.998,339.999 is z=65.570000
Tap drift (diff=65.9100mm) — reset
probe at 49.998,339.999 is z=9.562500
Tap drift (diff=56.0075mm) — reset
probe at 49.998,339.999 is z=0.997500
Tap drift (diff=8.5650mm) — reset
probe at 49.998,339.999 is z=1.030000
Tap drift (diff=0.0325mm) — reset
probe at 49.998,339.999 is z=1.032500
Tap OK (diff=0.0025mm, stable 2/5)
probe at 49.998,339.999 is z=1.037500
Tap OK (diff=0.0050mm, stable 3/5)
Tap OK (diff=0.0000mm, stable 4/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=1.0375 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z calibration complete!
probe at 49.998,339.999 is z=485.900000
Tap OK (diff=0.0000mm, stable 2/5)
Tap OK (diff=0.0000mm, stable 3/5)
VALIDATED: trigger_z=485.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 49.998,339.999 is z=485.902500
VALIDATED: trigger_z=485.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Tap OK (diff=0.0025mm, stable 4/5)
Tap OK (diff=0.0025mm, stable 3/5)
probe at 49.998,339.999 is z=485.930000
probe at 49.998,339.999 is z=485.905000
Tap drift (diff=0.0250mm) — reset
Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10)
probe at 49.998,339.999 is z=488.657500
Tap drift (diff=2.7550mm) — reset
probe at 49.998,339.999 is z=485.920000
Tap drift (diff=0.0150mm) — reset
probe at 49.998,339.999 is z=485.917500
probe at 49.998,339.999 is z=485.915000
|
| Screws tilt | PASS | 04:41:51 |
probe: at 54.997,328.001 bed will contact at z=1.302500
probe: at 54.997,328.001 bed will contact at z=1.315000
probe: at 54.997,328.001 bed will contact at z=1.342500
probe: at 380.001,328.001 bed will contact at z=1.220000
probe: at 380.001,328.001 bed will contact at z=1.237500
probe: at 380.001,328.001 bed will contact at z=1.227500
probe: at 380.001,101.996 bed will contact at z=1.222500
probe: at 380.001,101.996 bed will contact at z=1.235000
probe: at 380.001,101.996 bed will contact at z=1.230000
probe: at 54.997,101.996 bed will contact at z=1.260000
probe: at 54.997,101.996 bed will contact at z=1.275000
probe: at 54.997,101.996 bed will contact at z=1.277500
probe: at 217.505,214.498 bed will contact at z=1.287500
probe: at 217.505,214.498 bed will contact at z=1.285000
01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
front left screw (base) : x=72.0, y=298.0, z=1.31500
front right screw : x=397.0, y=298.0, z=1.22750 : adjust CCW 00:10
rear right screw : x=397.0, y=72.0, z=1.23000 : adjust CCW 00:10
rear left screw : x=72.0, y=72.0, z=1.27500 : adjust CCW 00:05
middle : x=234.5, y=184.5, z=1.28750 : adjust CCW 00:03
|