| Test | Result | Time | Details / log |
|---|---|---|---|
| MCU + firmware | PASS | 07:36:26 |
[mcu] version: 5ac7c301
[mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=550;ssr=SSR10DA;lot=20260618;uid=2ACAAE
[mcu] comment: -
[mcu SmartPiOne] version: 5ac7c301 (host SmartPi One)
MCU_UID=570059001051353135323934
|
| Home X | PASS | 07:36:53 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.7647 gap=1.2353 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=456.9969 gap=2.0031 (2/4)
tap 4: pos=456.8141 gap=2.1859 (3/4)
tap 5: pos=457.1797 gap=1.8203 fenetre=0.3656/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.3656mm (tol=0.0500). Zero pose en butee=457.0000
|
| Home Y | PASS | 07:37:28 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-18.5819 gap=1.4181 (chauffe, ignore)
tap 2: pos=-17.9969 gap=2.0031 (1/4)
tap 3: pos=-17.9969 gap=2.0031 (2/4)
tap 4: pos=-17.9969 gap=2.0031 (3/4)
tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
|
| Motherboard fan | PASS | 07:38:02 | |
| Part fan | PASS | 07:38:04 | |
| Hotend fan | PASS | 07:38:07 | |
| Hotend heat 220°C | PASS | 07:38:07 | |
| Bed heat 60°C | PASS | 07:38:21 | |
| Cutter (feed+cut) | PASS | 07:40:21 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.5697 gap=1.4303 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=457.1797 gap=1.8203 (2/4)
tap 4: pos=456.8141 gap=2.1859 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.3656/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.3656mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore)
tap 2: pos=-17.9969 gap=2.0031 (1/4)
tap 3: pos=-17.9969 gap=2.0031 (2/4)
tap 4: pos=-17.9969 gap=2.0031 (3/4)
tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Extruder 'extruder1' now syncing with ''
Extruder 'extruder0' now syncing with 'extruder'
QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte)
QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120
Extruder 'extruder0' now syncing with ''
|
| YMS-2 feed to head | PASS | 07:40:36 |
Extruder 'extruder0' now syncing with ''
Extruder 'extruder1' now syncing with ''
Extruder 'extruder1' now syncing with 'extruder'
QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte)
QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
|
| Z tap home + Zmax | PASS | 07:43:23 |
Run Current: 0.55A Hold Current: 0.55A
YUMI_SENSORLESS_HOME X: home base...
Run Current: 1.20A Hold Current: 1.09A
tap 1: pos=457.5819 gap=1.4181 (chauffe, ignore)
tap 2: pos=456.9969 gap=2.0031 (1/4)
tap 3: pos=457.1797 gap=1.8203 (2/4)
tap 4: pos=456.8141 gap=2.1859 (3/4)
tap 5: pos=456.9969 gap=2.0031 fenetre=0.3656/0.0500
YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.3656mm (tol=0.0500). Zero pose en butee=457.0000
YUMI_SENSORLESS_HOME Y: home base...
Run Current: 1.20A Hold Current: 1.20A
tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore)
tap 2: pos=-17.9969 gap=2.0031 (1/4)
tap 3: pos=-17.9969 gap=2.0031 (2/4)
tap 4: pos=-17.9969 gap=2.0031 (3/4)
tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500
YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.995,339.999 is z=384.420000
probe at 49.995,339.999 is z=384.437500
Tap drift (diff=0.0175mm) — reset
Tap OK (diff=0.0000mm, stable 2/5)
probe at 49.995,339.999 is z=384.450000
Tap drift (diff=0.0125mm) — reset
probe at 49.995,339.999 is z=384.467500
probe at 49.995,339.999 is z=384.470000
Tap OK (diff=0.0025mm, stable 2/5)
probe at 49.995,339.999 is z=384.482500
probe at 49.995,339.999 is z=384.472500
Tap OK (diff=0.0100mm, stable 2/5)
Tap drift (diff=0.0100mm) — reset
probe at 49.995,339.999 is z=384.477500
Tap OK (diff=0.0050mm, stable 2/5)
probe at 49.995,339.999 is z=384.475000
Tap OK (diff=0.0025mm, stable 3/5)
probe at 49.995,339.999 is z=384.485000
probe at 49.995,339.999 is z=384.492500
Tap OK (diff=0.0075mm, stable 2/5)
probe at 49.995,339.999 is z=384.495000
|
| Z tap repeatability | PASS | 07:48:27 |
OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.8950, 485.8925, 485.9125, 485.9000, 485.9025, 485.8975, 485.9025, 485.9000, 485.9000, 485.9000, 485.9025, 485.9000, 485.9050, 485.8950, 485.8975
Moving to tap point X=50.0 Y=340.0...
Probing with pressure switch...
probe at 49.998,339.999 is z=0.840000
probe at 49.998,339.999 is z=0.857500
Tap drift (diff=0.0175mm) — reset
probe at 49.998,339.999 is z=0.867500
Tap drift (diff=0.0100mm) — reset
probe at 49.998,339.999 is z=0.880000
Tap drift (diff=0.0125mm) — reset
probe at 49.998,339.999 is z=0.877500
Tap OK (diff=0.0025mm, stable 2/5)
probe at 49.998,339.999 is z=0.890000
probe at 49.998,339.999 is z=0.892500
probe at 49.998,339.999 is z=0.887500
Tap OK (diff=0.0050mm, stable 3/5)
Tap OK (diff=0.0025mm, stable 4/5)
probe at 49.998,339.999 is z=0.895000
Tap OK (diff=0.0050mm, stable 5/5)
VALIDATED: trigger_z=0.8950 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0)
Z calibration complete!
probe at 49.998,339.999 is z=485.865000
probe at 49.998,339.999 is z=485.892500
Tap drift (diff=0.0275mm) — reset
probe at 49.998,339.999 is z=485.895000
probe at 49.998,339.999 is z=485.900000
Tap OK (diff=0.0075mm, stable 4/5)
Tap OK (diff=0.0000mm, stable 5/5)
VALIDATED: trigger_z=485.8925 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 49.998,339.999 is z=485.875000
probe at 49.998,339.999 is z=485.910000
Tap drift (diff=0.0350mm) — reset
probe at 49.998,339.999 is z=485.902500
Tap OK (diff=0.0075mm, stable 2/5)
probe at 49.998,339.999 is z=485.907500
probe at 49.998,339.999 is z=485.912500
Tap OK (diff=0.0025mm, stable 5/5)
VALIDATED: trigger_z=485.9125 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
probe at 49.998,339.999 is z=485.867500
probe at 49.998,339.999 is z=485.897500
|
| Screws tilt | PASS | 07:49:06 |
probe: at 54.997,328.001 bed will contact at z=1.457500
probe: at 54.997,328.001 bed will contact at z=1.475000
probe: at 54.997,328.001 bed will contact at z=1.467500
probe: at 380.001,328.001 bed will contact at z=1.500000
probe: at 380.001,328.001 bed will contact at z=1.492500
probe: at 380.001,101.996 bed will contact at z=1.460000
probe: at 380.001,101.996 bed will contact at z=1.447500
probe: at 380.001,101.996 bed will contact at z=1.462500
probe: at 54.997,101.996 bed will contact at z=1.462500
probe: at 54.997,101.996 bed will contact at z=1.470000
probe: at 54.997,101.996 bed will contact at z=1.472500
probe: at 217.505,214.498 bed will contact at z=1.510000
probe: at 217.505,214.498 bed will contact at z=1.505000
01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise
front left screw (base) : x=72.0, y=298.0, z=1.46750
front right screw : x=397.0, y=298.0, z=1.49250 : adjust CW 00:03
rear right screw : x=397.0, y=72.0, z=1.46000 : adjust CCW 00:01
rear left screw : x=72.0, y=72.0, z=1.47000 : adjust CW 00:00
middle : x=234.5, y=184.5, z=1.50500 : adjust CW 00:05
|