SmartPi 1
SmartPi 2

580041000D51353234323830

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 110V · 550W · SSR SSR10DA
QC pad (MAC) : 0281EB778EE3
Start : 2026-07-31T05:01:04.104516 · End : 2026-07-31T05:46:31.952684 · Duration : 2727 s
Received (server) : 2026-07-31T06:12:19
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=110V bedw=550 ssr=SSR10DA lot=20260618 uid=2ACAAE

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 05:01:04
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=550;ssr=SSR10DA;lot=20260618;uid=2ACAAE [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=580041000D51353234323830
Home X PASS 05:35:07
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 05:35:47
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-18.7769 gap=1.2231 (1/4) tap 3: pos=-18.7769 gap=1.2231 (2/4) tap 4: pos=-18.7769 gap=1.2231 (3/4) tap 5: pos=-18.5819 gap=1.4181 fenetre=0.1950/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-18.7281 spread=0.1950mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 05:35:55
Part fan PASS 05:35:57
Hotend fan PASS 05:36:00
Hotend heat 220°C PASS 05:36:00
Bed heat 60°C PASS 05:36:28
Cutter (feed+cut) PASS 05:37:53
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-18.1797 gap=1.8203 (2/4) tap 4: pos=-18.5941 gap=1.4059 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.5972/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-18.1919 spread=0.5972mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 05:38:08
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 05:41:09
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9847 gap=2.0153 fenetre=0.0122/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9938 spread=0.0122mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.1797 gap=1.8203 (chauffe, ignore) tap 2: pos=-18.7769 gap=1.2231 (1/4) tap 3: pos=-18.7769 gap=1.2231 (2/4) tap 4: pos=-18.5941 gap=1.4059 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.7800/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-18.5362 spread=0.7800mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=407.680000 probe at 49.995,339.999 is z=408.127500 Tap drift (diff=0.4475mm) — reset Tap OK (diff=0.0000mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) probe at 49.995,339.999 is z=408.130000 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=408.1300 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete!
Z tap repeatability PASS 05:45:51 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.9900, 485.9200, 485.9050, 485.9000, 485.9025, 485.8975, 485.9025, 485.9025, 485.8975, 485.9000, 485.9025, 485.8975, 485.9025, 485.9000, 485.9025
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=452.862500 probe at 49.998,339.999 is z=0.982500 Tap drift (diff=451.8800mm) — reset probe at 49.998,339.999 is z=0.987500 Tap OK (diff=0.0050mm, stable 2/5) probe at 49.998,339.999 is z=0.990000 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=0.9900 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete! probe at 49.998,339.999 is z=485.900000 probe at 49.998,339.999 is z=485.910000 Tap drift (diff=0.0100mm) — reset Tap OK (diff=0.0100mm, stable 2/5) probe at 49.998,339.999 is z=485.922500 Tap drift (diff=0.0225mm) — reset probe at 49.998,339.999 is z=485.925000 Tap OK (diff=0.0025mm, stable 2/5) probe at 49.998,339.999 is z=485.917500 Tap OK (diff=0.0075mm, stable 3/5) Tap OK (diff=0.0050mm, stable 4/5) probe at 49.998,339.999 is z=485.920000 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=485.9200 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 49.998,339.999 is z=485.902500 Tap OK (diff=0.0000mm, stable 3/5) probe at 49.998,339.999 is z=485.905000 VALIDATED: trigger_z=485.9050 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 49.998,339.999 is z=485.895000 Tap OK (diff=0.0025mm, stable 4/5) VALIDATED: trigger_z=485.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 49.998,339.999 is z=485.897500 VALIDATED: trigger_z=485.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Tap OK (diff=0.0050mm, stable 3/5) VALIDATED: trigger_z=485.8975 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 49.998,339.999 is z=485.872500
Screws tilt PASS 05:46:31
probe: at 54.997,328.001 bed will contact at z=0.742500 probe: at 54.997,328.001 bed will contact at z=0.750000 probe: at 54.997,328.001 bed will contact at z=0.760000 probe: at 380.001,328.001 bed will contact at z=1.350000 probe: at 380.001,328.001 bed will contact at z=1.347500 probe: at 380.001,328.001 bed will contact at z=1.352500 probe: at 380.001,101.996 bed will contact at z=1.200000 probe: at 380.001,101.996 bed will contact at z=1.197500 probe: at 380.001,101.996 bed will contact at z=1.212500 probe: at 54.997,101.996 bed will contact at z=0.612500 probe: at 54.997,101.996 bed will contact at z=0.615000 probe: at 217.505,214.498 bed will contact at z=1.040000 probe: at 217.505,214.498 bed will contact at z=1.047500 probe: at 217.505,214.498 bed will contact at z=1.042500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=0.75000 front right screw : x=397.0, y=298.0, z=1.35000 : adjust CW 01:12 rear right screw : x=397.0, y=72.0, z=1.20000 : adjust CW 00:54 rear left screw : x=72.0, y=72.0, z=0.61250 : adjust CCW 00:16 middle : x=234.5, y=184.5, z=1.04250 : adjust CW 00:35

History — 4 reports for this machine

QC dateResultQC pad (MAC)Received (server)
2026-07-31T05:01:04.104516 PASS 580041000D51353234323830 2026-07-31T06:12:19
2026-07-31T05:02:39.963576 FAIL 580041000D51353234323830 2026-07-31T05:21:55
2026-07-31T04:19:27.384763 FAIL 580041000D51353234323830 2026-07-31T04:31:46
2026-07-31T03:11:42.648485 FAIL 580041000D51353234323830 2026-07-31T03:30:41