SmartPi 1
SmartPi 2

580050001051353135323934

PASS Grade A Grade B
Model : C335 · Batch : 20260618
Heated bed : 220V · 500W · SSR SSR10DA
QC pad (MAC) : 028133CB7186
Start : 2026-07-25T07:41:01.074261 · End : 2026-07-25T07:52:46.284668 · Duration : 705 s
Received (server) : 2026-07-25T07:57:33
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C335 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=500 ssr=SSR10DA lot=20260618 uid=36C6E9

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 07:41:01
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=500;ssr=SSR10DA;lot=20260618;uid=36C6E9 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=580050001051353135323934
Home X PASS 07:41:26
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000
Home Y PASS 07:42:01
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.6062 gap=1.3938 (chauffe, ignore) tap 2: pos=-30.7769 gap=1.2231 (1/4) tap 3: pos=-30.7769 gap=1.2231 (2/4) tap 4: pos=-30.7769 gap=1.2231 (3/4) tap 5: pos=-30.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-30.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 07:42:06
Part fan PASS 07:42:08
Hotend fan PASS 07:42:11
Hotend heat 220°C PASS 07:42:14
Bed heat 60°C PASS 07:42:31
Cutter (feed+cut) PASS 07:43:56
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=-30.7891 gap=1.2109 (1/4) tap 3: pos=-30.7647 gap=1.2353 (2/4) tap 4: pos=-30.7769 gap=1.2231 (3/4) tap 5: pos=-30.7769 gap=1.2231 fenetre=0.0244/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-30.7769 spread=0.0244mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 07:44:11
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 07:47:14
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.7525 gap=1.2475 (chauffe, ignore) tap 2: pos=357.0091 gap=1.9909 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0122/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9999 spread=0.0122mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7525 gap=1.2475 (chauffe, ignore) tap 2: pos=-30.7769 gap=1.2231 (1/4) tap 3: pos=-30.7769 gap=1.2231 (2/4) tap 4: pos=-30.7769 gap=1.2231 (3/4) tap 5: pos=-30.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-30.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.996,275.995 is z=395.792500 probe at 65.996,275.995 is z=360.902500 Tap drift (diff=34.8900mm) — reset probe at 65.996,275.995 is z=343.837500 Tap drift (diff=17.0650mm) — reset probe at 65.996,275.995 is z=311.375000 Tap drift (diff=32.4625mm) — reset probe at 65.996,275.995 is z=311.367500 Tap OK (diff=0.0075mm, stable 2/5) Tap OK (diff=0.0075mm, stable 3/5) probe at 65.996,275.995 is z=311.377500 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=311.3750 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete!
Z tap repeatability PASS 07:52:15 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.9075, 385.8975, 385.9000, 385.9025, 385.8975, 385.9000, 385.9025, 385.9025, 385.8950, 385.9025, 385.9000, 385.8975, 385.9025, 385.9000, 385.8975
Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.999,275.995 is z=395.570000 probe at 65.999,275.995 is z=346.605000 Tap drift (diff=48.9650mm) — reset probe at 65.999,275.995 is z=335.480000 Tap drift (diff=11.1250mm) — reset probe at 65.999,275.995 is z=328.212500 Tap drift (diff=7.2675mm) — reset probe at 65.999,275.995 is z=330.967500 Tap drift (diff=2.7550mm) — reset probe at 65.999,275.995 is z=329.925000 Tap drift (diff=1.0425mm) — reset probe at 65.999,275.995 is z=322.430000 Tap drift (diff=7.4950mm) — reset probe at 65.999,275.995 is z=325.165000 Tap drift (diff=2.7350mm) — reset probe at 65.999,275.995 is z=323.922500 Tap drift (diff=1.2425mm) — reset probe at 65.999,275.995 is z=325.042500 Tap drift (diff=1.1200mm) — reset probe at 65.999,275.995 is z=264.757500 Tap drift (diff=60.2850mm) — reset probe at 65.999,275.995 is z=254.485000 Tap drift (diff=10.2725mm) — reset probe at 65.999,275.995 is z=247.405000 Tap drift (diff=7.0800mm) — reset probe at 65.999,275.995 is z=239.317500 Tap drift (diff=8.0875mm) — reset probe at 65.999,275.995 is z=231.412500 Tap drift (diff=7.9050mm) — reset probe at 65.999,275.995 is z=223.370000 Tap drift (diff=8.0425mm) — reset probe at 65.999,275.995 is z=218.967500 Tap drift (diff=4.4025mm) — reset probe at 65.999,275.995 is z=221.965000 Tap drift (diff=2.9975mm) — reset probe at 65.999,275.995 is z=155.800000 Tap drift (diff=66.1650mm) — reset probe at 65.999,275.995 is z=48.290000
Screws tilt PASS 07:52:46
probe: at 67.000,271.004 bed will contact at z=1.092500 probe: at 67.000,271.004 bed will contact at z=1.102500 probe: at 67.000,271.004 bed will contact at z=1.095000 probe: at 267.996,271.004 bed will contact at z=1.050000 probe: at 267.996,271.004 bed will contact at z=1.057500 probe: at 267.996,271.004 bed will contact at z=1.055000 probe: at 267.996,71.995 bed will contact at z=1.000000 probe: at 267.996,71.995 bed will contact at z=1.012500 probe: at 267.996,71.995 bed will contact at z=1.010000 probe: at 67.000,71.995 bed will contact at z=1.027500 probe: at 67.000,71.995 bed will contact at z=1.025000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=84.0, y=241.0, z=1.09500 front right screw : x=285.0, y=241.0, z=1.05500 : adjust CCW 00:05 rear right screw : x=285.0, y=42.0, z=1.01000 : adjust CCW 00:10 rear left screw : x=84.0, y=42.0, z=1.02500 : adjust CCW 00:08