SmartPi 1
SmartPi 2

580068001051353135323934

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 220V · 750W · SSR SSR10DA
QC pad (MAC) : 0281605119E6
Start : 2026-08-18T07:02:57.472238 · End : 2026-08-18T07:16:17.350733 · Duration : 799 s
Received (server) : 2026-08-19T04:51:40
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=750 ssr=SSR10DA lot=20260618 uid=9221AF

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 07:02:57
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=580068001051353135323934
Home X PASS 07:03:23
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=457.1797 gap=1.8203 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.1828/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=457.0426 spread=0.1828mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 07:03:58
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-18.3625 gap=1.6375 fenetre=0.3656/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-18.0883 spread=0.3656mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 07:06:19
Part fan PASS 07:06:21
Hotend fan PASS 07:06:23
Hotend heat 220°C PASS 07:06:23
Bed heat 60°C PASS 07:06:24
Cutter (feed+cut) PASS 07:08:18
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=456.8141 gap=2.1859 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=457.1797 gap=1.8203 (3/4) tap 5: pos=456.8141 gap=2.1859 fenetre=0.3656/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9512 spread=0.3656mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 07:08:33
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 07:11:05
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=413.050000 probe at 49.995,339.999 is z=413.060000 Tap drift (diff=0.0100mm) — reset probe at 49.995,339.999 is z=413.062500 Tap OK (diff=0.0025mm, stable 2/5) probe at 49.995,339.999 is z=413.065000 Tap OK (diff=0.0025mm, stable 3/5) probe at 49.995,339.999 is z=413.067500 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=413.0675 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete!
Z tap repeatability PASS 07:15:39 OK: 3 taps convergents spread=0.0025mm (tol=0.0500) sur 15 taps | taps=23.7950, 485.9025, 485.9125, 485.8950, 485.9025, 485.8900, 485.9150, 485.9000, 485.8875, 485.8975, 485.9125, 485.9050, 485.8900, 485.8975, 485.9075
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=23.785000 probe at 49.998,339.999 is z=23.795000 Tap OK (diff=0.0100mm, stable 2/5) probe at 49.998,339.999 is z=23.797500 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=23.7950 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete! probe at 49.998,339.999 is z=485.897500 probe at 49.998,339.999 is z=485.900000 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 49.998,339.999 is z=485.902500 VALIDATED: trigger_z=485.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 49.998,339.999 is z=485.915000 Tap OK (diff=0.0000mm, stable 2/5) probe at 49.998,339.999 is z=485.912500 probe at 49.998,339.999 is z=485.910000 Tap OK (diff=0.0025mm, stable 4/5) VALIDATED: trigger_z=485.9125 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 49.998,339.999 is z=485.905000 Tap OK (diff=0.0075mm, stable 2/5) Tap OK (diff=0.0050mm, stable 3/5) Tap OK (diff=0.0050mm, stable 4/5) probe at 49.998,339.999 is z=485.895000 VALIDATED: trigger_z=485.8950 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 49.998,339.999 is z=485.892500 Tap OK (diff=0.0075mm, stable 5/5) probe at 49.998,339.999 is z=485.882500 probe at 49.998,339.999 is z=485.887500 Tap OK (diff=0.0050mm, stable 2/5) probe at 49.998,339.999 is z=485.885000 probe at 49.998,339.999 is z=485.890000 Tap OK (diff=0.0050mm, stable 5/5) VALIDATED: trigger_z=485.8900 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Tap OK (diff=0.0075mm, stable 3/5)
Screws tilt PASS 07:16:17
probe: at 54.997,328.001 bed will contact at z=2.190000 probe: at 54.997,328.001 bed will contact at z=2.197500 probe: at 54.997,328.001 bed will contact at z=2.192500 probe: at 380.001,328.001 bed will contact at z=2.222500 probe: at 380.001,328.001 bed will contact at z=2.230000 probe: at 380.001,328.001 bed will contact at z=2.217500 probe: at 380.001,101.996 bed will contact at z=2.152500 probe: at 380.001,101.996 bed will contact at z=2.132500 probe: at 380.001,101.996 bed will contact at z=2.140000 probe: at 54.997,101.996 bed will contact at z=2.217500 probe: at 54.997,101.996 bed will contact at z=2.222500 probe: at 54.997,101.996 bed will contact at z=2.212500 probe: at 217.505,214.498 bed will contact at z=2.180000 probe: at 217.505,214.498 bed will contact at z=2.187500 probe: at 217.505,214.498 bed will contact at z=2.185000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=2.19250 front right screw : x=397.0, y=298.0, z=2.22250 : adjust CW 00:04 rear right screw : x=397.0, y=72.0, z=2.14000 : adjust CCW 00:06 rear left screw : x=72.0, y=72.0, z=2.21750 : adjust CW 00:03 middle : x=234.5, y=184.5, z=2.18500 : adjust CCW 00:01