← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

590026001051353135323934

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 110V · 550W · SSR SSR10DA
QC pad (MAC) : 0281EB778EE3
Start : 2026-07-31T02:15:42.148993 · End : 2026-07-31T02:28:37.278430 · Duration : 775 s
Received (server) : 2026-07-31T02:51:41
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=110V bedw=550 ssr=SSR10DA lot=20260618 uid=2ACAAE

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 02:15:42
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=550;ssr=SSR10DA;lot=20260618;uid=2ACAAE [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=590026001051353135323934
Home X PASS 02:16:08
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 02:16:53
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1 rejete: aucun contact sur 7.0mm (No trigger on probe after full movement) tap 2 rejete: aucun contact sur 7.0mm (No trigger on probe after full movement) YUMI_SENSORLESS_HOME Y: home de base suspect (pas de contact) -> re-home de recuperation 1/2 tap 3: pos=-17.9969 gap=2.0031 (chauffe, ignore) tap 4: pos=-17.9969 gap=2.0031 (1/4) tap 5: pos=-17.9969 gap=2.0031 (2/4) tap 6: pos=-17.9969 gap=2.0031 (3/4) tap 7: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (2 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 02:17:15
Part fan PASS 02:17:18
Hotend fan PASS 02:17:20
Hotend heat 220°C PASS 02:17:20
Bed heat 60°C PASS 02:17:55
Cutter (feed+cut) PASS 02:19:29
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1 rejete: cible atteinte sans buter (gap=0.0531) tap 2 rejete: cible atteinte sans buter (gap=0.6381) YUMI_SENSORLESS_HOME Y: home de base suspect (pas de contact) -> re-home de recuperation 1/2 tap 3: pos=-18.2528 gap=1.7472 (chauffe, ignore) tap 4: pos=-17.9969 gap=2.0031 (1/4) tap 5: pos=-17.9969 gap=2.0031 (2/4) tap 6: pos=-17.9969 gap=2.0031 (3/4) tap 7: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (2 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 02:19:44
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 02:23:08
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.4112 gap=1.5888 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=410.722500 probe at 49.995,339.999 is z=410.752500 Tap drift (diff=0.0300mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 49.995,339.999 is z=410.755000 Tap OK (diff=0.0025mm, stable 3/5) probe at 49.995,339.999 is z=410.765000 Tap drift (diff=0.0100mm) — reset probe at 49.995,339.999 is z=410.775000 Tap OK (diff=0.0100mm, stable 2/5) probe at 49.995,339.999 is z=410.760000 Tap OK (diff=0.0050mm, stable 3/5) probe at 49.995,339.999 is z=410.767500 Tap OK (diff=0.0075mm, stable 4/5) probe at 49.995,339.999 is z=410.770000 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=410.7700 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete!
Z tap repeatability PASS 02:27:56 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.0300, 485.9075, 485.9100, 485.8975, 485.9050, 485.9025, 485.8975, 485.9025, 485.9000, 485.9025, 485.9000, 485.9000, 485.9000, 485.9000, 485.9000
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=1.012500 probe at 49.998,339.999 is z=1.022500 Tap drift (diff=0.0100mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 49.998,339.999 is z=1.032500 probe at 49.998,339.999 is z=1.030000 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=1.0300 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete! probe at 49.998,339.999 is z=485.900000 probe at 49.998,339.999 is z=485.905000 Tap OK (diff=0.0050mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 49.998,339.999 is z=485.907500 Tap OK (diff=0.0025mm, stable 4/5) VALIDATED: trigger_z=485.9075 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Tap OK (diff=0.0075mm, stable 2/5) probe at 49.998,339.999 is z=485.910000 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=485.9100 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 49.998,339.999 is z=485.897500 probe at 49.998,339.999 is z=485.895000 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0050mm, stable 3/5) VALIDATED: trigger_z=485.8975 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 49.998,339.999 is z=485.902500 probe at 49.998,339.999 is z=485.970000 Tap drift (diff=0.0675mm) — reset probe at 49.998,339.999 is z=487.510000 Tap drift (diff=1.5400mm) — reset Tap drift (diff=1.6100mm) — reset Tap OK (diff=0.0050mm, stable 4/5) VALIDATED: trigger_z=485.9050 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) VALIDATED: trigger_z=485.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) VALIDATED: trigger_z=485.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Screws tilt PASS 02:28:37
probe: at 54.997,328.001 bed will contact at z=0.770000 probe: at 54.997,328.001 bed will contact at z=0.777500 probe: at 54.997,328.001 bed will contact at z=0.790000 probe: at 380.001,328.001 bed will contact at z=0.802500 probe: at 380.001,328.001 bed will contact at z=0.822500 probe: at 380.001,328.001 bed will contact at z=0.812500 probe: at 380.001,101.996 bed will contact at z=0.652500 probe: at 380.001,101.996 bed will contact at z=0.645000 probe: at 54.997,101.996 bed will contact at z=0.692500 probe: at 54.997,101.996 bed will contact at z=0.682500 probe: at 54.997,101.996 bed will contact at z=0.697500 probe: at 217.505,214.498 bed will contact at z=0.750000 probe: at 217.505,214.498 bed will contact at z=0.760000 probe: at 217.505,214.498 bed will contact at z=0.755000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=0.77750 front right screw : x=397.0, y=298.0, z=0.81250 : adjust CW 00:04 rear right screw : x=397.0, y=72.0, z=0.65250 : adjust CCW 00:15 rear left screw : x=72.0, y=72.0, z=0.69250 : adjust CCW 00:10 middle : x=234.5, y=184.5, z=0.75500 : adjust CCW 00:03