← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

5B005E000C51353234323830

PASS Grade A Grade B
Model : C235 · Batch : 20260616
Heated bed : 220V · 300W · SSR SSR10DA
QC pad (MAC) : 02813B23751D
Start : 2026-06-29T07:50:33.570741 · End : 2026-06-29T08:03:00.830610 · Duration : 747 s
Received (server) : 2026-06-30T01:57:56
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C235 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=300 ssr=SSR10DA lot=20260616 uid=61C229

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 07:50:33
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C235;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=300;ssr=SSR10DA;lot=20260616;uid=61C229 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=5B005E000C51353234323830
Home X PASS 07:50:59
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000
Home Y PASS 07:51:28
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 07:52:23
Part fan PASS 07:52:27
Hotend fan PASS 07:52:29
Hotend heat 220°C PASS 07:52:29
Bed heat 60°C PASS 07:52:30
Cutter (feed+cut) PASS 07:54:01
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 07:54:28
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 150mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 07:57:29
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 31.003,211.998 is z=265.320000 probe at 31.003,211.998 is z=101.620000 Tap drift (diff=163.7000mm) — reset probe at 31.003,211.998 is z=103.727500 Tap drift (diff=2.1075mm) — reset probe at 31.003,211.998 is z=105.897500 Tap drift (diff=2.1700mm) — reset probe at 31.003,211.998 is z=108.580000 Tap drift (diff=2.6825mm) — reset probe at 31.003,211.998 is z=110.727500 Tap drift (diff=2.1475mm) — reset probe at 31.003,211.998 is z=113.355000 Tap drift (diff=2.6275mm) — reset probe at 31.003,211.998 is z=116.027500 Tap drift (diff=2.6725mm) — reset probe at 31.003,211.998 is z=118.612500 Tap drift (diff=2.5850mm) — reset probe at 31.003,211.998 is z=120.417500 Tap drift (diff=1.8050mm) — reset probe at 31.003,211.998 is z=122.815000 Tap drift (diff=2.3975mm) — reset
Z tap repeatability PASS 08:02:26 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.8975, 255.9000, 255.8975, 255.9025, 255.8900, 256.1950, 255.9000, 255.9000, 255.9000, 255.9000, 255.9025, 255.9000, 255.9000, 255.9025, 255.9225
Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 30.994,211.998 is z=264.640000 probe at 30.994,211.998 is z=266.145000 Tap drift (diff=1.5050mm) — reset probe at 30.994,211.998 is z=267.317500 Tap rejete (vibration chassis, z=267.3175 > max-z_hop) -> pas de remontee, on poursuit la descente (1) probe at 30.994,211.998 is z=0.867500 probe at 30.994,211.998 is z=0.897500 Tap drift (diff=0.0300mm) — reset Tap OK (diff=0.0000mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=0.8975 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete! probe at 30.994,211.998 is z=255.877500 probe at 30.994,211.998 is z=255.900000 Tap drift (diff=0.0225mm) — reset VALIDATED: trigger_z=255.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.897500 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=255.8975 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.872500 probe at 30.994,211.998 is z=257.427500 Tap drift (diff=1.5550mm) — reset probe at 30.994,211.998 is z=255.902500 Tap drift (diff=1.5250mm) — reset probe at 30.994,211.998 is z=257.270000 Tap drift (diff=1.3675mm) — reset VALIDATED: trigger_z=255.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Tap drift (diff=0.0275mm) — reset Tap OK (diff=0.0025mm, stable 4/5) probe at 30.994,211.998 is z=255.890000 Tap OK (diff=0.0075mm, stable 5/5) VALIDATED: trigger_z=255.8900 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.882500 probe at 30.994,211.998 is z=257.037500 Tap drift (diff=1.1550mm) — reset
Screws tilt PASS 08:03:00
probe: at 32.495,205.497 bed will contact at z=0.745000 probe: at 32.495,205.497 bed will contact at z=1.065000 Probe samples exceed tolerance. Retrying... probe: at 32.495,205.497 bed will contact at z=1.077500 probe: at 32.495,205.497 bed will contact at z=1.087500 probe: at 32.495,205.497 bed will contact at z=1.075000 probe: at 206.996,205.497 bed will contact at z=2.980000 probe: at 206.996,205.497 bed will contact at z=3.315000 probe: at 206.996,205.497 bed will contact at z=3.307500 probe: at 206.996,205.497 bed will contact at z=3.312500 probe: at 206.996,205.497 bed will contact at z=3.305000 probe: at 206.996,31.995 bed will contact at z=3.982500 probe: at 206.996,31.995 bed will contact at z=4.310000 probe: at 206.996,31.995 bed will contact at z=4.287500 probe: at 206.996,31.995 bed will contact at z=4.297500 probe: at 206.996,31.995 bed will contact at z=4.305000 probe: at 32.495,31.995 bed will contact at z=2.120000 probe: at 32.495,31.995 bed will contact at z=2.435000 probe: at 32.495,31.995 bed will contact at z=2.445000 probe: at 32.495,31.995 bed will contact at z=2.440000 probe: at 32.495,31.995 bed will contact at z=2.437500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=49.5, y=175.5, z=1.07750 front right screw : x=224.0, y=175.5, z=3.30750 : adjust CW 04:28 rear right screw : x=224.0, y=2.0, z=4.29750 : adjust CW 06:26 rear left screw : x=49.5, y=2.0, z=2.44000 : adjust CW 02:43

History — 2 reports for this machine

QC dateResultQC pad (MAC)Received (server)
2026-06-29T07:50:33.570741 PASS 5B005E000C51353234323830 2026-06-30T01:57:56
2026-06-29T07:47:16.572934 FAIL 5B005E000C51353234323830 2026-06-30T01:57:52