← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

5C005F000C51353234323830

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 220V · 750W · SSR SSR10DA
QC pad (MAC) : 02817A147AB3
Start : 2026-08-12T07:19:12.397703 · End : 2026-08-12T07:32:03.030138 · Duration : 770 s
Received (server) : 2026-08-12T07:38:39
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=750 ssr=SSR10DA lot=20260618 uid=9221AF

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 07:19:12
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=5C005F000C51353234323830
Home X PASS 07:19:37
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5819 gap=1.4181 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 07:20:13
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 07:20:44
Part fan PASS 07:20:46
Hotend fan PASS 07:20:48
Hotend heat 220°C PASS 07:20:48
Bed heat 60°C PASS 07:20:48
Cutter (feed+cut) PASS 07:22:21
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=457.7769 gap=1.2231 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.7800/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=457.1919 spread=0.7800mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-17.9847 gap=2.0153 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 07:22:36
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 07:25:23
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=457.7769 gap=1.2231 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.7800/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=457.1919 spread=0.7800mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-17.9847 gap=2.0153 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=471.180000 probe at 49.995,339.999 is z=439.830000 Tap drift (diff=31.3500mm) — reset probe at 49.995,339.999 is z=394.740000 Tap drift (diff=45.0900mm) — reset probe at 49.995,339.999 is z=394.745000 Tap OK (diff=0.0050mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 49.995,339.999 is z=394.747500 Tap OK (diff=0.0025mm, stable 4/5) probe at 49.995,339.999 is z=394.750000 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=394.7500 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete!
Z tap repeatability PASS 07:31:23 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.1250, 486.0975, 486.1025, 486.1000, 486.1025, 486.0975, 486.1025, 486.1050, 486.0975, 486.1000, 486.1050, 486.0975, 486.1000, 486.1025, 486.1000
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=495.775000 probe at 49.998,339.999 is z=498.417500 Tap rejete (vibration chassis, z=498.4175 > max-z_hop) -> pas de remontee, on poursuit la descente (1) probe at 49.998,339.999 is z=498.227500 Tap rejete (vibration chassis, z=498.2275 > max-z_hop) -> pas de remontee, on poursuit la descente (2) probe at 49.998,339.999 is z=498.055000 Tap rejete (vibration chassis, z=498.0550 > max-z_hop) -> pas de remontee, on poursuit la descente (3) probe at 49.998,339.999 is z=497.855000 Tap rejete (vibration chassis, z=497.8550 > max-z_hop) -> pas de remontee, on poursuit la descente (4) probe at 49.998,339.999 is z=497.690000 Tap rejete (vibration chassis, z=497.6900 > max-z_hop) -> pas de remontee, on poursuit la descente (5) probe at 49.998,339.999 is z=497.620000 Tap rejete (vibration chassis, z=497.6200 > max-z_hop) -> pas de remontee, on poursuit la descente (6) probe at 49.998,339.999 is z=497.455000 Tap rejete (vibration chassis, z=497.4550 > max-z_hop) -> pas de remontee, on poursuit la descente (7) probe at 49.998,339.999 is z=497.295000 Tap rejete (vibration chassis, z=497.2950 > max-z_hop) -> pas de remontee, on poursuit la descente (8) probe at 49.998,339.999 is z=497.132500 Tap rejete (vibration chassis, z=497.1325 > max-z_hop) -> pas de remontee, on poursuit la descente (9) probe at 49.998,339.999 is z=497.070000 Tap rejete (vibration chassis, z=497.0700 > max-z_hop) -> pas de remontee, on poursuit la descente (10) probe at 49.998,339.999 is z=497.017500 Tap rejete (vibration chassis, z=497.0175 > max-z_hop) -> pas de remontee, on poursuit la descente (11) probe at 49.998,339.999 is z=496.820000 probe at 49.998,339.999 is z=492.815000 Tap drift (diff=4.0050mm) — reset probe at 49.998,339.999 is z=473.772500 Tap drift (diff=19.0425mm) — reset probe at 49.998,339.999 is z=424.175000 Tap drift (diff=49.5975mm) — reset probe at 49.998,339.999 is z=421.497500 Tap drift (diff=2.6775mm) — reset probe at 49.998,339.999 is z=416.820000 Tap drift (diff=4.6775mm) — reset probe at 49.998,339.999 is z=410.260000 Tap drift (diff=6.5600mm) — reset probe at 49.998,339.999 is z=413.012500 Tap drift (diff=2.7525mm) — reset
Screws tilt PASS 07:32:03
probe: at 54.997,328.001 bed will contact at z=1.132500 probe: at 54.997,328.001 bed will contact at z=1.145000 probe: at 54.997,328.001 bed will contact at z=1.105000 probe: at 380.001,328.001 bed will contact at z=1.067500 probe: at 380.001,328.001 bed will contact at z=1.072500 probe: at 380.001,101.996 bed will contact at z=1.025000 probe: at 380.001,101.996 bed will contact at z=1.027500 probe: at 380.001,101.996 bed will contact at z=1.032500 probe: at 54.997,101.996 bed will contact at z=1.072500 probe: at 54.997,101.996 bed will contact at z=1.062500 probe: at 217.505,214.498 bed will contact at z=1.207500 probe: at 217.505,214.498 bed will contact at z=1.202500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=1.13250 front right screw : x=397.0, y=298.0, z=1.06750 : adjust CCW 00:08 rear right screw : x=397.0, y=72.0, z=1.02750 : adjust CCW 00:13 rear left screw : x=72.0, y=72.0, z=1.07250 : adjust CCW 00:07 middle : x=234.5, y=184.5, z=1.20750 : adjust CW 00:09

History — 2 reports for this machine

QC dateResultQC pad (MAC)Received (server)
2026-08-12T07:19:12.397703 PASS 5C005F000C51353234323830 2026-08-12T07:38:39
2026-08-12T07:11:44.716597 FAIL 5C005F000C51353234323830 2026-08-12T07:18:30