SmartPi 1
SmartPi 2

5D003F000D51353234323830

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 220V · 750W · SSR SSR10DA
QC pad (MAC) : 0281E38DE8BE
Start : 2026-10-20T06:59:20.899141 · End : 2026-10-20T07:12:43.526301 · Duration : 802 s
Received (server) : 2026-10-20T07:15:33
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=750 ssr=SSR10DA lot=20260618 uid=9221AF

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 06:59:21
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=5D003F000D51353234323830
Home X PASS 06:59:45
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 07:00:18
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-18.1797 gap=1.8203 (1/4) tap 3: pos=-18.7769 gap=1.2231 (2/4) tap 4: pos=-18.5941 gap=1.4059 (3/4) tap 5: pos=-18.1797 gap=1.8203 fenetre=0.5972/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-18.4326 spread=0.5972mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 07:00:22
Part fan PASS 07:00:24
Hotend fan PASS 07:00:27
Hotend heat 220°C PASS 07:00:27
Bed heat 60°C PASS 07:00:27
Cutter (feed+cut) PASS 07:01:57
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5819 gap=1.4181 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.9597 gap=1.0403 (chauffe, ignore) tap 2: pos=-18.5941 gap=1.4059 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-18.1797 gap=1.8203 (3/4) tap 5: pos=-18.5941 gap=1.4059 fenetre=0.5972/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-18.3412 spread=0.5972mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 07:02:19
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 125mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 07:05:22
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5575 gap=1.4425 (chauffe, ignore) tap 2: pos=457.0091 gap=1.9909 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0122/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9999 spread=0.0122mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.9597 gap=1.0403 (chauffe, ignore) tap 2: pos=-18.5941 gap=1.4059 (1/4) tap 3: pos=-18.1797 gap=1.8203 (2/4) tap 4: pos=-18.7769 gap=1.2231 (3/4) tap 5: pos=-18.7769 gap=1.2231 fenetre=0.5972/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-18.5819 spread=0.5972mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=385.485000 probe at 49.995,339.999 is z=385.297500 Tap drift (diff=0.1875mm) — reset probe at 49.995,339.999 is z=385.337500 Tap drift (diff=0.0400mm) — reset Tap OK (diff=0.0000mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=385.3375 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete!
Z tap repeatability PASS 07:12:10 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=11.3400, 485.9000, 485.9025, 485.8575, 485.8575, 485.9000, 485.9000, 485.9000, 485.9000, 485.9000, 485.9000, 485.9000, 485.9000, 485.9000, 485.9000
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=11.425000 probe at 49.998,339.999 is z=11.300000 Tap drift (diff=0.1250mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 49.998,339.999 is z=11.257500 Tap drift (diff=0.0425mm) — reset probe at 49.998,339.999 is z=11.340000 Tap drift (diff=0.0825mm) — reset Tap drift (diff=0.0400mm) — reset probe at 49.998,339.999 is z=11.337500 Tap drift (diff=0.0375mm) — reset Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 49.998,339.999 is z=11.297500 probe at 49.998,339.999 is z=11.342500 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=11.3400 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete! probe at 49.998,339.999 is z=485.900000 probe at 49.998,339.999 is z=485.857500 Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=485.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 49.998,339.999 is z=485.820000 probe at 49.998,339.999 is z=485.860000 probe at 49.998,339.999 is z=485.897500 probe at 49.998,339.999 is z=485.902500 Tap OK (diff=0.0025mm, stable 3/5) VALIDATED: trigger_z=485.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 49.998,339.999 is z=485.895000 Tap drift (diff=0.0350mm) — reset probe at 49.998,339.999 is z=485.815000 Tap drift (diff=0.0800mm) — reset probe at 49.998,339.999 is z=485.855000 VALIDATED: trigger_z=485.8575 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 49.998,339.999 is z=485.942500
Screws tilt PASS 07:12:43
probe: at 54.997,328.001 bed will contact at z=4.432500 probe: at 54.997,328.001 bed will contact at z=4.440000 probe: at 54.997,328.001 bed will contact at z=4.442500 probe: at 380.001,328.001 bed will contact at z=4.365000 probe: at 380.001,328.001 bed will contact at z=4.370000 probe: at 380.001,328.001 bed will contact at z=4.367500 probe: at 380.001,101.996 bed will contact at z=4.330000 probe: at 380.001,101.996 bed will contact at z=4.337500 probe: at 380.001,101.996 bed will contact at z=4.325000 probe: at 54.997,101.996 bed will contact at z=4.345000 probe: at 54.997,101.996 bed will contact at z=4.342500 probe: at 54.997,101.996 bed will contact at z=4.350000 probe: at 217.505,214.498 bed will contact at z=4.412500 probe: at 217.505,214.498 bed will contact at z=4.420000 probe: at 217.505,214.498 bed will contact at z=4.430000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=4.44000 front right screw : x=397.0, y=298.0, z=4.36750 : adjust CCW 00:09 rear right screw : x=397.0, y=72.0, z=4.33000 : adjust CCW 00:13 rear left screw : x=72.0, y=72.0, z=4.34500 : adjust CCW 00:11 middle : x=234.5, y=184.5, z=4.42000 : adjust CCW 00:02

History — 2 reports for this machine

QC dateResultQC pad (MAC)Received (server)
2026-10-20T06:59:20.899141 PASS 5D003F000D51353234323830 2026-10-20T07:15:33
2026-10-20T06:52:44.803421 PARTIAL 5D003F000D51353234323830 2026-10-20T06:55:38