SmartPi 1
SmartPi 2

60005B000C51353234323830

PASS Grade A Grade B
Model : C235 · Batch : 20260616
Heated bed : 220V · 300W · SSR SSR10DA
QC pad (MAC) : 0281DE6A3114
Start : 2026-06-30T02:17:00.619289 · End : 2026-06-30T02:28:29.538414 · Duration : 688 s
Received (server) : 2026-06-30T02:35:32
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C235 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=300 ssr=SSR10DA lot=20260616 uid=61C229

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 02:17:00
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C235;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=300;ssr=SSR10DA;lot=20260616;uid=61C229 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=60005B000C51353234323830
Home X PASS 02:17:22
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000
Home Y PASS 02:17:53
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.3991 gap=1.6009 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 02:19:17
Part fan PASS 02:19:20
Hotend fan PASS 02:19:23
Hotend heat 220°C PASS 02:19:23
Bed heat 60°C PASS 02:19:23
Cutter (feed+cut) PASS 02:21:16
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-30.1797 gap=1.8203 (2/4) tap 4: pos=-29.8141 gap=2.1859 (3/4) tap 5: pos=-30.1797 gap=1.8203 fenetre=0.3656/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.0426 spread=0.3656mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 02:21:27
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 50mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 02:23:43
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=256.1919 gap=1.8081 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.1950/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=256.0456 spread=0.1950mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1797 gap=1.8203 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-30.1797 gap=1.8203 fenetre=0.1828/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.0426 spread=0.1828mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 31.003,211.998 is z=175.855000 probe at 31.003,211.998 is z=175.895000 Tap drift (diff=0.0400mm) — reset probe at 31.003,211.998 is z=175.887500 Tap OK (diff=0.0075mm, stable 2/5) probe at 31.003,211.998 is z=175.890000 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=175.8900 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete!
Z tap repeatability PASS 02:28:00 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.8925, 255.9025, 255.8775, 255.9000, 255.8975, 255.9000, 255.9000, 255.9000, 255.9000, 255.9000, 255.9000, 255.9000, 255.9000, 255.9000, 255.9000
Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 30.994,211.998 is z=253.137500 probe at 30.994,211.998 is z=224.420000 Tap drift (diff=28.7175mm) — reset probe at 30.994,211.998 is z=124.625000 Tap drift (diff=99.7950mm) — reset probe at 30.994,211.998 is z=50.860000 Tap drift (diff=73.7650mm) — reset probe at 30.994,211.998 is z=52.225000 Tap drift (diff=1.3650mm) — reset probe at 30.994,211.998 is z=0.822500 Tap drift (diff=51.4025mm) — reset probe at 30.994,211.998 is z=0.875000 Tap drift (diff=0.0525mm) — reset probe at 30.994,211.998 is z=0.890000 Tap drift (diff=0.0150mm) — reset probe at 30.994,211.998 is z=0.892500 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=0.8925 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete! probe at 30.994,211.998 is z=255.867500 probe at 30.994,211.998 is z=255.902500 Tap drift (diff=0.0350mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 30.994,211.998 is z=255.905000 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=255.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=262.182500 probe at 30.994,211.998 is z=255.865000 Tap drift (diff=6.3175mm) — reset probe at 30.994,211.998 is z=255.877500 Tap drift (diff=0.0125mm) — reset VALIDATED: trigger_z=255.8775 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.887500
Screws tilt PASS 02:28:29
probe: at 32.495,205.497 bed will contact at z=2.460000 probe: at 32.495,205.497 bed will contact at z=2.487500 probe: at 32.495,205.497 bed will contact at z=2.552500 Probe samples exceed tolerance. Retrying... probe: at 32.495,205.497 bed will contact at z=2.520000 probe: at 32.495,205.497 bed will contact at z=2.510000 probe: at 32.495,205.497 bed will contact at z=2.540000 probe: at 206.996,205.497 bed will contact at z=3.995000 probe: at 206.996,205.497 bed will contact at z=4.012500 probe: at 206.996,31.995 bed will contact at z=6.292500 probe: at 206.996,31.995 bed will contact at z=6.315000 probe: at 206.996,31.995 bed will contact at z=6.317500 probe: at 32.495,31.995 bed will contact at z=4.952500 probe: at 32.495,31.995 bed will contact at z=5.030000 probe: at 32.495,31.995 bed will contact at z=5.007500 probe: at 32.495,31.995 bed will contact at z=5.040000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=49.5, y=175.5, z=2.52000 front right screw : x=224.0, y=175.5, z=4.01250 : adjust CW 02:59 rear right screw : x=224.0, y=2.0, z=6.31500 : adjust CW 07:35 rear left screw : x=49.5, y=2.0, z=5.00750 : adjust CW 04:58