SmartPi 1
SmartPi 2

630046000D51353234323830

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 110V · 550W · SSR SSR10DA
QC pad (MAC) : 028103694A6F
Start : 2026-08-01T04:14:20.530225 · End : 2026-08-01T04:27:03.948480 · Duration : 763 s
Received (server) : 2026-08-01T04:29:12
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=110V bedw=550 ssr=SSR10DA lot=20260618 uid=2ACAAE

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 04:14:20
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=550;ssr=SSR10DA;lot=20260618;uid=2ACAAE [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=630046000D51353234323830
Home X PASS 04:14:47
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5819 gap=1.4181 (chauffe, ignore) tap 2: pos=456.8019 gap=2.1981 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.1950/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9481 spread=0.1950mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 04:15:23
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-30.1919 gap=1.8081 (2/4) tap 4: pos=-30.5819 gap=1.4181 (3/4) tap 5: pos=-30.1919 gap=1.8081 fenetre=0.5850/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.2406 spread=0.5850mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 04:15:31
Part fan PASS 04:15:34
Hotend fan PASS 04:15:37
Hotend heat 220°C PASS 04:15:42
Bed heat 60°C PASS 04:16:13
Cutter (feed+cut) PASS 04:17:46
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.3869 gap=1.6131 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=457.1919 gap=1.8081 (2/4) tap 4: pos=456.8019 gap=2.1981 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.3900/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.3900mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 04:18:01
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 04:21:37
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.1797 gap=1.8203 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1797 gap=1.8203 (chauffe, ignore) tap 2: pos=-30.7769 gap=1.2231 (1/4) tap 3: pos=-30.7769 gap=1.2231 (2/4) tap 4: pos=-30.7769 gap=1.2231 (3/4) tap 5: pos=-30.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-30.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,340.003 is z=412.587500 probe at 49.995,340.003 is z=412.602500 Tap drift (diff=0.0150mm) — reset probe at 49.995,340.003 is z=412.600000 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=412.6025 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete!
Z tap repeatability PASS 04:26:17 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.0700, 486.1050, 486.1025, 486.1100, 486.0975, 486.0975, 486.1050, 486.1025, 486.1000, 486.1000, 486.1000, 486.1025, 486.0975, 486.1000, 486.1025
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,340.003 is z=375.940000 probe at 49.998,340.003 is z=294.740000 Tap drift (diff=81.2000mm) — reset probe at 49.998,340.003 is z=149.732500 Tap drift (diff=145.0075mm) — reset probe at 49.998,340.003 is z=143.665000 Tap drift (diff=6.0675mm) — reset probe at 49.998,340.003 is z=1.055000 Tap drift (diff=142.6100mm) — reset probe at 49.998,340.003 is z=1.065000 Tap drift (diff=0.0100mm) — reset probe at 49.998,340.003 is z=1.067500 Tap OK (diff=0.0025mm, stable 2/5) probe at 49.998,340.003 is z=1.070000 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=1.0700 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete! probe at 49.998,340.003 is z=486.097500 probe at 49.998,340.003 is z=486.100000 probe at 49.998,340.003 is z=486.102500 probe at 49.998,340.003 is z=486.105000 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=486.1050 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,340.003 is z=486.092500 Tap OK (diff=0.0050mm, stable 2/5) Tap OK (diff=0.0050mm, stable 4/5) VALIDATED: trigger_z=486.1025 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,340.003 is z=486.095000 probe at 49.998,340.003 is z=486.107500 Tap OK (diff=0.0000mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 49.998,340.003 is z=486.110000 VALIDATED: trigger_z=486.1100 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,340.003 is z=486.090000 Tap OK (diff=0.0050mm, stable 3/5)
Screws tilt PASS 04:27:03
probe: at 54.997,315.001 bed will contact at z=1.805000 probe: at 54.997,315.001 bed will contact at z=1.815000 probe: at 54.997,315.001 bed will contact at z=1.795000 probe: at 380.001,315.001 bed will contact at z=1.687500 probe: at 380.001,315.001 bed will contact at z=1.697500 probe: at 380.001,315.001 bed will contact at z=1.680000 probe: at 380.001,83.000 bed will contact at z=1.692500 probe: at 380.001,83.000 bed will contact at z=1.690000 probe: at 380.001,83.000 bed will contact at z=1.707500 probe: at 54.997,83.000 bed will contact at z=1.597500 probe: at 54.997,83.000 bed will contact at z=1.852500 Probe samples exceed tolerance. Retrying... probe: at 54.997,83.000 bed will contact at z=1.792500 probe: at 54.997,83.000 bed will contact at z=1.845000 probe: at 54.997,83.000 bed will contact at z=1.892500 probe: at 54.997,83.000 bed will contact at z=1.840000 probe: at 54.997,83.000 bed will contact at z=1.857500 probe: at 54.997,83.000 bed will contact at z=1.835000 probe: at 54.997,83.000 bed will contact at z=1.875000 probe: at 217.505,202.498 bed will contact at z=1.735000 probe: at 217.505,202.498 bed will contact at z=1.745000 probe: at 217.505,202.498 bed will contact at z=1.740000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=285.0, z=1.80500 front right screw : x=397.0, y=285.0, z=1.68750 : adjust CCW 00:14 rear right screw : x=397.0, y=53.0, z=1.69250 : adjust CCW 00:13 rear left screw : x=72.0, y=53.0, z=1.85750 : adjust CW 00:06 rear left screw : x=234.5, y=172.5, z=1.74000 : adjust CCW 00:08