← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

640042000D51353234323830

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 110V · 550W · SSR SSR10DA
QC pad (MAC) : 02813B23751D
Start : 2026-08-04T07:04:21.665619 · End : 2026-08-04T07:17:00.632998 · Duration : 758 s
Received (server) : 2026-08-04T07:24:51
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=110V bedw=550 ssr=SSR10DA lot=20260618 uid=2ACAAE

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 07:04:21
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=550;ssr=SSR10DA;lot=20260618;uid=2ACAAE [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=640042000D51353234323830
Home X PASS 07:04:48
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.7525 gap=1.2475 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 07:05:24
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.6062 gap=1.3938 (chauffe, ignore) tap 2: pos=-18.7769 gap=1.2231 (1/4) tap 3: pos=-18.7769 gap=1.2231 (2/4) tap 4: pos=-18.7769 gap=1.2231 (3/4) tap 5: pos=-18.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 07:06:11
Part fan PASS 07:06:13
Hotend fan PASS 07:06:15
Hotend heat 220°C PASS 07:06:16
Bed heat 60°C PASS 07:06:43
Cutter (feed+cut) PASS 07:08:16
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.8141 gap=2.1859 (2/4) tap 4: pos=457.1797 gap=1.8203 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.3656/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.3656mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=-18.7769 gap=1.2231 (1/4) tap 3: pos=-18.7769 gap=1.2231 (2/4) tap 4: pos=-18.7769 gap=1.2231 (3/4) tap 5: pos=-18.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 07:08:31
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 07:11:41
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.7525 gap=1.2475 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=-18.7769 gap=1.2231 (1/4) tap 3: pos=-18.7769 gap=1.2231 (2/4) tap 4: pos=-18.7647 gap=1.2353 (3/4) tap 5: pos=-18.7891 gap=1.2109 fenetre=0.0244/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.7769 spread=0.0244mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=410.060000 probe at 49.995,339.999 is z=410.072500 Tap drift (diff=0.0125mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 49.995,339.999 is z=410.075000 Tap OK (diff=0.0025mm, stable 3/5) probe at 49.995,339.999 is z=410.077500 Tap OK (diff=0.0025mm, stable 4/5) probe at 49.995,339.999 is z=410.080000 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=410.0800 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete!
Z tap repeatability PASS 07:16:19 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.0900, 486.1025, 486.1025, 486.1025, 486.1000, 486.1025, 486.1000, 486.1000, 486.1000, 486.1000, 486.1000, 486.1025, 486.1000, 486.1075, 486.0975
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=1.052500 probe at 49.998,339.999 is z=1.065000 Tap drift (diff=0.0125mm) — reset probe at 49.998,339.999 is z=1.070000 Tap OK (diff=0.0050mm, stable 2/5) probe at 49.998,339.999 is z=1.080000 Tap drift (diff=0.0100mm) — reset probe at 49.998,339.999 is z=1.082500 Tap OK (diff=0.0025mm, stable 2/5) probe at 49.998,339.999 is z=1.085000 Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) probe at 49.998,339.999 is z=1.090000 Tap OK (diff=0.0050mm, stable 5/5) VALIDATED: trigger_z=1.0900 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete! probe at 49.998,339.999 is z=486.092500 probe at 49.998,339.999 is z=486.095000 probe at 49.998,339.999 is z=486.097500 probe at 49.998,339.999 is z=486.100000 Tap OK (diff=0.0025mm, stable 4/5) probe at 49.998,339.999 is z=486.102500 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=486.1025 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Tap OK (diff=0.0000mm, stable 5/5) Tap OK (diff=0.0000mm, stable 3/5) VALIDATED: trigger_z=486.1000 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Switch encore declenche (vibration) -> attente 2.0s puis nouvelle tentative (1/10) probe at 49.998,339.999 is z=490.322500 Tap drift (diff=4.2275mm) — reset probe at 49.998,339.999 is z=486.105000 probe at 49.998,339.999 is z=486.107500 VALIDATED: trigger_z=486.1075 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) VALIDATED: trigger_z=486.0975 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000)
Screws tilt PASS 07:17:00
probe: at 54.997,328.001 bed will contact at z=2.207500 probe: at 54.997,328.001 bed will contact at z=2.185000 probe: at 54.997,328.001 bed will contact at z=2.247500 Probe samples exceed tolerance. Retrying... probe: at 54.997,328.001 bed will contact at z=2.237500 probe: at 54.997,328.001 bed will contact at z=2.217500 probe: at 54.997,328.001 bed will contact at z=2.227500 probe: at 380.001,328.001 bed will contact at z=2.062500 probe: at 380.001,328.001 bed will contact at z=2.030000 probe: at 380.001,101.996 bed will contact at z=2.082500 probe: at 380.001,101.996 bed will contact at z=2.072500 probe: at 380.001,101.996 bed will contact at z=2.080000 probe: at 54.997,101.996 bed will contact at z=2.247500 probe: at 54.997,101.996 bed will contact at z=2.272500 probe: at 54.997,101.996 bed will contact at z=2.280000 probe: at 217.505,214.498 bed will contact at z=2.102500 probe: at 217.505,214.498 bed will contact at z=2.100000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=2.22750 front right screw : x=397.0, y=298.0, z=2.06250 : adjust CCW 00:20 rear right screw : x=397.0, y=72.0, z=2.08000 : adjust CCW 00:18 rear left screw : x=72.0, y=72.0, z=2.27250 : adjust CW 00:05 middle : x=234.5, y=184.5, z=2.10250 : adjust CCW 00:15