← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

660047000D51353234323830

PASS Grade A Grade B
Model : C335 · Batch : 20260618
Heated bed : 110V · 500W · SSR SSR10DA
QC pad (MAC) : 0281D225B2A9
Start : 2026-07-30T00:45:15.750749 · End : 2026-07-30T00:57:53.518468 · Duration : 757 s
Received (server) : 2026-07-30T01:08:54
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C335 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=110V bedw=500 ssr=SSR10DA lot=20260618 uid=B3D7BD

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 00:45:15
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C335;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=110V;bedw=500;ssr=SSR10DA;lot=20260618;uid=B3D7BD [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=660047000D51353234323830
Home X PASS 00:45:40
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000
Home Y PASS 00:46:11
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.1919 gap=1.8081 (chauffe, ignore) tap 2: pos=-30.5819 gap=1.4181 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.5850/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-30.1431 spread=0.5850mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 00:46:17
Part fan PASS 00:46:19
Hotend fan PASS 00:46:21
Hotend heat 220°C PASS 00:46:31
Bed heat 60°C PASS 00:46:35
Cutter (feed+cut) PASS 00:48:08
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 00:48:22
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 00:51:25
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=357.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=356.9969 gap=2.0031 (1/4) tap 3: pos=356.9969 gap=2.0031 (2/4) tap 4: pos=356.9969 gap=2.0031 (3/4) tap 5: pos=356.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=356.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=357.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-29.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.996,275.995 is z=311.540000 probe at 65.996,275.995 is z=311.547500 Tap OK (diff=0.0075mm, stable 2/5) Tap OK (diff=0.0075mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) probe at 65.996,275.995 is z=311.545000 Tap OK (diff=0.0050mm, stable 5/5) VALIDATED: trigger_z=311.5450 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete!
Z tap repeatability PASS 00:57:24 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.9050, 385.9050, 385.9050, 385.9025, 385.9000, 385.9000, 385.8925, 385.9075, 385.9025, 385.9000, 385.9025, 385.9000, 385.9025, 385.8875, 385.9050
Moving to tap point X=66.0 Y=276.0... Probing with pressure switch... probe at 65.999,275.995 is z=343.747500 probe at 65.999,275.995 is z=0.902500 Tap drift (diff=342.8450mm) — reset probe at 65.999,275.995 is z=0.900000 Tap OK (diff=0.0025mm, stable 2/5) probe at 65.999,275.995 is z=0.905000 Tap OK (diff=0.0050mm, stable 3/5) probe at 65.999,275.995 is z=0.912500 Tap OK (diff=0.0075mm, stable 4/5) Tap OK (diff=0.0075mm, stable 5/5) VALIDATED: trigger_z=0.9050 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (66.0, 276.0) ~ point de tap (66.0, 276.0) Z calibration complete! probe at 65.999,275.995 is z=385.842500 probe at 65.999,275.995 is z=385.887500 Tap drift (diff=0.0450mm) — reset probe at 65.999,275.995 is z=385.907500 Tap drift (diff=0.0200mm) — reset probe at 65.999,275.995 is z=385.905000 probe at 65.999,275.995 is z=385.897500 Tap OK (diff=0.0075mm, stable 3/5) probe at 65.999,275.995 is z=385.912500 Tap drift (diff=0.0150mm) — reset Tap OK (diff=0.0000mm, stable 2/5) Tap drift (diff=0.0250mm) — reset Tap OK (diff=0.0075mm, stable 2/5) probe at 65.999,275.995 is z=385.900000 Tap OK (diff=0.0025mm, stable 4/5) VALIDATED: trigger_z=385.9050 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 65.999,275.995 is z=385.895000 Tap OK (diff=0.0100mm, stable 2/5) probe at 65.999,275.995 is z=385.870000 Tap drift (diff=0.0175mm) — reset probe at 65.999,275.995 is z=385.910000 Tap drift (diff=0.0225mm) — reset probe at 65.999,275.995 is z=385.890000 probe at 65.999,275.995 is z=385.915000 Tap OK (diff=0.0100mm, stable 3/5)
Screws tilt PASS 00:57:53
probe: at 67.000,271.004 bed will contact at z=2.165000 probe: at 67.000,271.004 bed will contact at z=2.167500 probe: at 67.000,271.004 bed will contact at z=2.145000 probe: at 267.996,271.004 bed will contact at z=2.102500 probe: at 267.996,271.004 bed will contact at z=2.095000 probe: at 267.996,271.004 bed will contact at z=2.097500 probe: at 267.996,71.995 bed will contact at z=2.157500 probe: at 267.996,71.995 bed will contact at z=2.155000 probe: at 67.000,71.995 bed will contact at z=2.190000 probe: at 67.000,71.995 bed will contact at z=2.200000 probe: at 67.000,71.995 bed will contact at z=2.207500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=84.0, y=241.0, z=2.16500 front right screw : x=285.0, y=241.0, z=2.09750 : adjust CCW 00:08 rear right screw : x=285.0, y=42.0, z=2.15750 : adjust CCW 00:01 rear left screw : x=84.0, y=42.0, z=2.20000 : adjust CW 00:04

History — 2 reports for this machine

QC dateResultQC pad (MAC)Received (server)
2026-07-30T00:45:15.750749 PASS 660047000D51353234323830 2026-07-30T01:08:54
2026-07-28T05:21:34.989275 FAIL 660047000D51353234323830 2026-07-28T05:40:19