SmartPi 1
SmartPi 2

670046000D51353234323830

PASS Grade A Grade B
Model : C235 · Batch : 20260616
Heated bed : 220V · 300W · SSR SSR10DA
QC pad (MAC) : 02813C788EB7
Start : 2026-07-01T05:02:36.950712 · End : 2026-07-01T05:12:40.382963 · Duration : 603 s
Received (server) : 2026-07-01T07:37:45
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C235 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22DH mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=300 ssr=SSR10DA lot=20260616 uid=61C229

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 05:02:37
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C235;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22DH;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=300;ssr=SSR10DA;lot=20260616;uid=61C229 [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=670046000D51353234323830
Home X PASS 05:03:02
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.3991 gap=1.6009 (chauffe, ignore) tap 2: pos=256.1919 gap=1.8081 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.8019 gap=2.1981 fenetre=0.3900/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=255.9969 spread=0.3900mm (tol=0.0500). Zero pose en butee=256.0000
Home Y PASS 05:03:33
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.3869 gap=1.6131 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.8019 gap=2.1981 (2/4) tap 4: pos=-30.1919 gap=1.8081 (3/4) tap 5: pos=-29.8019 gap=2.1981 fenetre=0.3900/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-29.9481 spread=0.3900mm (tol=0.0500). Zero pose en butee=-30.0000
Motherboard fan PASS 05:03:39
Part fan PASS 05:03:44
Hotend fan PASS 05:03:46
Hotend heat 220°C PASS 05:03:55
Bed heat 60°C PASS 05:04:13
Cutter (feed+cut) PASS 05:05:39
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.3869 gap=1.6131 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=255.9969 gap=2.0031 (2/4) tap 4: pos=256.1919 gap=1.8081 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.1950/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=256.0456 spread=0.1950mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-30.1919 gap=1.8081 (1/4) tap 3: pos=-29.9847 gap=2.0153 (2/4) tap 4: pos=-29.8141 gap=2.1859 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.3778/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.3778mm (tol=0.0500). Zero pose en butee=-30.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 05:05:53
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 05:08:17
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=256.3869 gap=1.6131 (chauffe, ignore) tap 2: pos=255.9969 gap=2.0031 (1/4) tap 3: pos=256.1919 gap=1.8081 (2/4) tap 4: pos=255.9969 gap=2.0031 (3/4) tap 5: pos=255.9969 gap=2.0031 fenetre=0.1950/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=256.0456 spread=0.1950mm (tol=0.0500). Zero pose en butee=256.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-30.7769 gap=1.2231 (chauffe, ignore) tap 2: pos=-29.9969 gap=2.0031 (1/4) tap 3: pos=-29.9969 gap=2.0031 (2/4) tap 4: pos=-29.9969 gap=2.0031 (3/4) tap 5: pos=-29.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-29.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-30.0000 Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 31.003,211.998 is z=242.807500 probe at 31.003,211.998 is z=184.390000 Tap drift (diff=58.4175mm) — reset probe at 31.003,211.998 is z=184.407500 Tap drift (diff=0.0175mm) — reset probe at 31.003,211.998 is z=184.410000 Tap OK (diff=0.0025mm, stable 2/5) probe at 31.003,211.998 is z=186.895000 Tap drift (diff=2.4850mm) — reset probe at 31.003,211.998 is z=184.405000 Tap drift (diff=2.4900mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 31.003,211.998 is z=184.382500 Tap drift (diff=0.0225mm) — reset probe at 31.003,211.998 is z=184.380000 Tap OK (diff=0.0000mm, stable 3/5) Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=184.3800 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete!
Z tap repeatability PASS 05:12:11 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=0.8975, 255.9050, 255.8975, 255.9025, 255.8925, 255.9050, 255.8975, 255.9000, 255.9025, 255.8975, 255.9000, 255.9025, 255.8975, 255.9025, 255.8950
Moving to tap point X=31.0 Y=212.0... Probing with pressure switch... probe at 30.994,211.998 is z=0.890000 probe at 30.994,211.998 is z=0.892500 Tap OK (diff=0.0025mm, stable 2/5) probe at 30.994,211.998 is z=0.897500 Tap OK (diff=0.0050mm, stable 3/5) Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=0.8975 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) Maillage OK (config): zero_reference_position (31.0, 212.0) ~ point de tap (31.0, 212.0) Z calibration complete! probe at 30.994,211.998 is z=255.900000 probe at 30.994,211.998 is z=255.902500 Tap OK (diff=0.0000mm, stable 3/5) probe at 30.994,211.998 is z=255.905000 Tap OK (diff=0.0025mm, stable 4/5) VALIDATED: trigger_z=255.9050 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.897500 Tap OK (diff=0.0000mm, stable 2/5) Tap OK (diff=0.0025mm, stable 3/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=255.8975 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) VALIDATED: trigger_z=255.9025 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) probe at 30.994,211.998 is z=255.892500 Tap OK (diff=0.0050mm, stable 2/5) probe at 30.994,211.998 is z=255.895000 VALIDATED: trigger_z=255.8925 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) VALIDATED: trigger_z=255.9000 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000) VALIDATED: trigger_z=255.8950 -> Z=0 pose 0.1000 au-dessus du tap (compression=0.0000 + z_offset=0.1000)
Screws tilt PASS 05:12:40
probe: at 32.495,205.497 bed will contact at z=1.822500 probe: at 32.495,205.497 bed will contact at z=1.832500 probe: at 32.495,205.497 bed will contact at z=1.820000 probe: at 206.996,205.497 bed will contact at z=3.927500 probe: at 206.996,205.497 bed will contact at z=3.930000 probe: at 206.996,205.497 bed will contact at z=3.935000 probe: at 206.996,31.995 bed will contact at z=4.165000 probe: at 206.996,31.995 bed will contact at z=4.170000 probe: at 206.996,31.995 bed will contact at z=4.177500 probe: at 32.495,31.995 bed will contact at z=2.452500 probe: at 32.495,31.995 bed will contact at z=2.400000 Probe samples exceed tolerance. Retrying... probe: at 32.495,31.995 bed will contact at z=2.492500 probe: at 32.495,31.995 bed will contact at z=2.422500 probe: at 32.495,31.995 bed will contact at z=2.420000 probe: at 32.495,31.995 bed will contact at z=2.455000 probe: at 32.495,31.995 bed will contact at z=2.445000 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=49.5, y=175.5, z=1.82250 front right screw : x=224.0, y=175.5, z=3.93000 : adjust CW 04:13 rear right screw : x=224.0, y=2.0, z=4.17000 : adjust CW 04:42 rear left screw : x=49.5, y=2.0, z=2.44500 : adjust CW 01:15

History — 2 reports for this machine

QC dateResultQC pad (MAC)Received (server)
2026-07-01T05:02:36.950712 PASS 670046000D51353234323830 2026-07-01T07:37:45
2026-06-29T01:39:12.439828 FAIL 670046000D51353234323830 2026-06-29T01:47:46