SmartPi 1
SmartPi 2

690040000D51353234323830

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 220V · 750W · SSR SSR10DA
QC pad (MAC) : 0281AE52CB5F
Start : 2026-08-12T05:45:13.281882 · End : 2026-08-12T05:57:16.162870 · Duration : 722 s
Received (server) : 2026-08-12T06:25:50
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=750 ssr=SSR10DA lot=20260618 uid=9221AF

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 05:45:13
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=690040000D51353234323830
Home X PASS 05:45:38
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.7647 gap=1.2353 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 05:46:15
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.3747 gap=1.6253 (chauffe, ignore) tap 2: pos=-18.3991 gap=1.6009 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.4022/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-18.0974 spread=0.4022mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 05:46:25
Part fan PASS 05:46:28
Hotend fan PASS 05:46:30
Hotend heat 220°C PASS 05:46:30
Bed heat 60°C PASS 05:46:53
Cutter (feed+cut) PASS 05:48:34
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1 rejete: cible atteinte sans buter (gap=0.0653) tap 2 rejete: cible atteinte sans buter (gap=0.0531) YUMI_SENSORLESS_HOME X: home de base suspect (pas de contact) -> re-home de recuperation 1/2 tap 3 rejete: cible atteinte sans buter (gap=0.0653) tap 4 rejete: cible atteinte sans buter (gap=0.0531) YUMI_SENSORLESS_HOME X: home de base suspect (pas de contact) -> re-home de recuperation 2/2 tap 5: pos=457.3747 gap=1.6253 (chauffe, ignore) tap 6: pos=456.9969 gap=2.0031 (1/4) tap 7: pos=456.9969 gap=2.0031 (2/4) tap 8: pos=456.9969 gap=2.0031 (3/4) tap 9: pos=456.8019 gap=2.1981 fenetre=0.1950/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (4 rejetes) -> moyenne=456.9481 spread=0.1950mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-17.9969 gap=2.0031 (3/4) tap 5: pos=-17.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-17.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 05:48:49
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 75mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 05:51:59
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5697 gap=1.4303 (chauffe, ignore) tap 2: pos=457.1919 gap=1.8081 (1/4) tap 3: pos=456.8019 gap=2.1981 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.3900/0.0500 YUMI_SENSORLESS_HOME X IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.3900mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-17.9969 gap=2.0031 (chauffe, ignore) tap 2: pos=-17.9969 gap=2.0031 (1/4) tap 3: pos=-17.9969 gap=2.0031 (2/4) tap 4: pos=-18.3747 gap=1.6253 (3/4) tap 5: pos=-18.3991 gap=1.6009 fenetre=0.4022/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-18.1919 spread=0.4022mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=407.005000 probe at 49.995,339.999 is z=407.025000 Tap drift (diff=0.0200mm) — reset probe at 49.995,339.999 is z=407.030000 Tap OK (diff=0.0050mm, stable 2/5) probe at 49.995,339.999 is z=407.032500 Tap OK (diff=0.0025mm, stable 3/5) probe at 49.995,339.999 is z=407.035000 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=407.0350 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete!
Z tap repeatability PASS 05:56:38 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=1.1150, 486.1075, 486.1025, 486.1000, 486.1025, 486.1000, 486.1025, 486.1025, 486.1025, 486.1000, 486.1000, 486.1000, 486.1025, 486.1000, 486.1025
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=1.095000 probe at 49.998,339.999 is z=1.105000 Tap drift (diff=0.0100mm) — reset probe at 49.998,339.999 is z=1.107500 Tap OK (diff=0.0025mm, stable 2/5) probe at 49.998,339.999 is z=1.110000 Tap OK (diff=0.0025mm, stable 3/5) probe at 49.998,339.999 is z=1.112500 Tap OK (diff=0.0025mm, stable 4/5) probe at 49.998,339.999 is z=1.115000 Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=1.1150 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete! probe at 49.998,339.999 is z=486.095000 probe at 49.998,339.999 is z=486.105000 Tap OK (diff=0.0000mm, stable 2/5) probe at 49.998,339.999 is z=486.107500 Tap OK (diff=0.0000mm, stable 4/5) Tap OK (diff=0.0000mm, stable 5/5) VALIDATED: trigger_z=486.1075 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,339.999 is z=486.100000 Tap OK (diff=0.0050mm, stable 2/5) probe at 49.998,339.999 is z=486.102500 VALIDATED: trigger_z=486.1025 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Tap OK (diff=0.0000mm, stable 3/5) VALIDATED: trigger_z=486.1000 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,339.999 is z=486.097500 Tap OK (diff=0.0075mm, stable 2/5) probe at 49.998,339.999 is z=486.092500 probe at 49.998,339.999 is z=486.087500 Tap drift (diff=0.0150mm) — reset probe at 49.998,339.999 is z=486.090000
Screws tilt PASS 05:57:16
probe: at 54.997,328.001 bed will contact at z=1.957500 probe: at 54.997,328.001 bed will contact at z=1.972500 probe: at 380.001,328.001 bed will contact at z=1.960000 probe: at 380.001,328.001 bed will contact at z=1.965000 probe: at 380.001,101.996 bed will contact at z=1.912500 probe: at 380.001,101.996 bed will contact at z=1.917500 probe: at 380.001,101.996 bed will contact at z=1.915000 probe: at 54.997,101.996 bed will contact at z=1.980000 probe: at 54.997,101.996 bed will contact at z=1.995000 probe: at 217.505,214.498 bed will contact at z=2.022500 probe: at 217.505,214.498 bed will contact at z=2.020000 probe: at 217.505,214.498 bed will contact at z=2.037500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=1.97250 front right screw : x=397.0, y=298.0, z=1.96000 : adjust CCW 00:01 rear right screw : x=397.0, y=72.0, z=1.91500 : adjust CCW 00:07 rear left screw : x=72.0, y=72.0, z=1.99500 : adjust CW 00:03 middle : x=234.5, y=184.5, z=2.02250 : adjust CW 00:06