← Home · All machines · All YMS reports → · Packed printers · Trash
SmartPi 1
SmartPi 2

690051000C51353234323830

PASS Grade A Grade B
Model : C435 · Batch : 20260618
Heated bed : 220V · 750W · SSR SSR10DA
QC pad (MAC) : 0281D225B2A9
Start : 2026-10-21T02:35:05.032609 · End : 2026-10-21T02:48:30.157464 · Duration : 805 s
Received (server) : 2026-10-21T02:50:42
yumi_config : board=SMART_MAKER_1_X cpu=STM32F401 conn=UART device=C435 x=SMART_TMC2209_V2 y=SMART_TMC2209_V2 z=SMART_TMC2209_V2 e0=SMART_TMC2209_V2 e1=SMART_TMC2209_V2 mx=42BYGH3023-B-22DH my=42BYGH3023-B-22S148H mz=42BYGH2216-B-24DH piezo=YN15T-85A1-W100_15-2P pzb=Smart_Z-Offset pzbv=0.2 mains=220V bedw=750 ssr=SSR10DA lot=20260618 uid=9221AF

Proof photos (packing)

Switch to mobile pipeline mode
TestResultTimeDetails / log
MCU + firmware PASS 02:35:05
[mcu] version: 5ac7c301 [mcu] board=SMART_MAKER_1_X;cpu=STM32F401;conn=UART;device=C435;x=SMART_TMC2209_V2;y=SMART_TMC2209_V2;z=SMART_TMC2209_V2;e0=SMART_TMC2209_V2;e1=SMART_TMC2209_V2;mx=42BYGH3023-B-22DH;my=42BYGH3023-B-22S148H;mz=42BYGH2216-B-24DH;piezo=YN15T-85A1-W100_15-2P;pzb=Smart_Z-Offset;pzbv=0.2;mains=220V;bedw=750;ssr=SSR10DA;lot=20260618;uid=9221AF [mcu] comment: - [mcu SmartPiOne] version: 5ac7c301 (host SmartPi One) MCU_UID=690051000C51353234323830
Home X PASS 02:35:31
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000
Home Y PASS 02:36:06
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.9719 gap=1.0281 (chauffe, ignore) tap 2: pos=-18.9597 gap=1.0403 (1/4) tap 3: pos=-18.7769 gap=1.2231 (2/4) tap 4: pos=-18.7769 gap=1.2231 (3/4) tap 5: pos=-18.7769 gap=1.2231 fenetre=0.1828/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (0 rejetes) -> moyenne=-18.8226 spread=0.1828mm (tol=0.0500). Zero pose en butee=-18.0000
Motherboard fan PASS 02:36:19
Part fan PASS 02:36:23
Hotend fan PASS 02:36:26
Hotend heat 220°C PASS 02:36:27
Bed heat 60°C PASS 02:36:51
Cutter (feed+cut) PASS 02:38:30
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1 rejete: cible atteinte sans buter (gap=0.8453) tap 2: pos=-18.7769 gap=1.2231 (chauffe, ignore) tap 3: pos=-18.3991 gap=1.6009 (1/4) tap 4: pos=-18.7769 gap=1.2231 (2/4) tap 5: pos=-18.1919 gap=1.8081 (3/4) tap 6: pos=-18.7769 gap=1.2231 fenetre=0.5850/0.0500 YUMI_SENSORLESS_HOME Y IMPRECIS: 4 taps valides (1 rejetes) -> moyenne=-18.5362 spread=0.5850mm (tol=0.0500). Zero pose en butee=-18.0000 Extruder 'extruder1' now syncing with '' Extruder 'extruder0' now syncing with 'extruder' QC CUTTER: motion sensor YMS-1 a change d'etat (mouvement detecte) QC CUTTER: extrude 60 + refroidit poop 5s + coupe + retracte 120 Extruder 'extruder0' now syncing with ''
YMS-2 feed to head PASS 02:38:49
Extruder 'extruder0' now syncing with '' Extruder 'extruder1' now syncing with '' Extruder 'extruder1' now syncing with 'extruder' QC E1_HEAD: motion sensor YMS-2 a change d'etat (mouvement detecte) QC E1_HEAD: filament a la tete apres 100mm + motion sensor YMS-2 OK
Z tap home + Zmax PASS 02:42:32
Run Current: 0.55A Hold Current: 0.55A YUMI_SENSORLESS_HOME X: home base... Run Current: 1.20A Hold Current: 1.09A tap 1: pos=457.5941 gap=1.4059 (chauffe, ignore) tap 2: pos=456.9969 gap=2.0031 (1/4) tap 3: pos=456.9969 gap=2.0031 (2/4) tap 4: pos=456.9969 gap=2.0031 (3/4) tap 5: pos=456.9969 gap=2.0031 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME X OK: 4 taps valides (0 rejetes) -> moyenne=456.9969 spread=0.0000mm (tol=0.0500). Zero pose en butee=457.0000 YUMI_SENSORLESS_HOME Y: home base... Run Current: 1.20A Hold Current: 1.20A tap 1: pos=-18.9719 gap=1.0281 (chauffe, ignore) tap 2: pos=-18.7769 gap=1.2231 (1/4) tap 3: pos=-18.7769 gap=1.2231 (2/4) tap 4: pos=-18.7769 gap=1.2231 (3/4) tap 5: pos=-18.7769 gap=1.2231 fenetre=0.0000/0.0500 YUMI_SENSORLESS_HOME Y OK: 4 taps valides (0 rejetes) -> moyenne=-18.7769 spread=0.0000mm (tol=0.0500). Zero pose en butee=-18.0000 Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.995,339.999 is z=486.092500 probe at 49.995,339.999 is z=476.492500 Tap drift (diff=9.6000mm) — reset probe at 49.995,339.999 is z=476.167500 Tap drift (diff=0.3250mm) — reset probe at 49.995,339.999 is z=472.650000 Tap drift (diff=3.5175mm) — reset probe at 49.995,339.999 is z=472.652500 Tap OK (diff=0.0025mm, stable 2/5) probe at 49.995,339.999 is z=471.850000 Tap drift (diff=0.8025mm) — reset probe at 49.995,339.999 is z=468.492500 Tap drift (diff=3.3575mm) — reset probe at 49.995,339.999 is z=457.420000 Tap drift (diff=11.0725mm) — reset probe at 49.995,339.999 is z=426.655000 Tap drift (diff=30.7650mm) — reset probe at 49.995,339.999 is z=429.132500 Tap drift (diff=2.4775mm) — reset probe at 49.995,339.999 is z=426.532500 Tap drift (diff=2.6000mm) — reset
Z tap repeatability PASS 02:47:49 OK: 3 taps convergents spread=0.0000mm (tol=0.0500) sur 15 taps | taps=5.4325, 486.1025, 486.0925, 486.1050, 486.0975, 486.1000, 486.1000, 486.1000, 486.0975, 486.1000, 486.1025, 486.1000, 486.1000, 486.1000, 486.1000
Moving to tap point X=50.0 Y=340.0... Probing with pressure switch... probe at 49.998,339.999 is z=7.340000 probe at 49.998,339.999 is z=5.437500 Tap drift (diff=1.9025mm) — reset probe at 49.998,339.999 is z=5.432500 Tap OK (diff=0.0050mm, stable 2/5) Tap OK (diff=0.0000mm, stable 3/5) probe at 49.998,339.999 is z=5.465000 Tap drift (diff=0.0325mm) — reset Tap OK (diff=0.0000mm, stable 2/5) probe at 49.998,339.999 is z=5.435000 Tap OK (diff=0.0025mm, stable 4/5) Tap OK (diff=0.0025mm, stable 5/5) VALIDATED: trigger_z=5.4325 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) Maillage OK (config): zero_reference_position (50.0, 340.0) ~ point de tap (50.0, 340.0) Z calibration complete! probe at 49.998,339.999 is z=487.487500 probe at 49.998,339.999 is z=486.130000 Tap drift (diff=1.3575mm) — reset probe at 49.998,339.999 is z=486.102500 Tap drift (diff=0.0275mm) — reset probe at 49.998,339.999 is z=486.100000 Tap OK (diff=0.0025mm, stable 2/5) Tap OK (diff=0.0025mm, stable 3/5) probe at 49.998,339.999 is z=486.095000 Tap OK (diff=0.0075mm, stable 4/5) Tap OK (diff=0.0075mm, stable 5/5) VALIDATED: trigger_z=486.1025 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,339.999 is z=486.122500 probe at 49.998,339.999 is z=486.092500 Tap OK (diff=0.0075mm, stable 3/5) VALIDATED: trigger_z=486.0925 -> Z=0 pose -0.1000 au-dessus du tap (compression=0.0000 - z_offset=0.1000) probe at 49.998,339.999 is z=486.107500 probe at 49.998,339.999 is z=486.097500 Tap OK (diff=0.0100mm, stable 4/5) Tap drift (diff=0.0100mm) — reset probe at 49.998,339.999 is z=486.045000 Tap drift (diff=0.0625mm) — reset Tap drift (diff=0.0575mm) — reset
Screws tilt PASS 02:48:30
probe: at 54.997,328.001 bed will contact at z=1.780000 probe: at 380.001,328.001 bed will contact at z=1.717500 probe: at 380.001,328.001 bed will contact at z=1.772500 Probe samples exceed tolerance. Retrying... probe: at 380.001,328.001 bed will contact at z=1.750000 probe: at 380.001,328.001 bed will contact at z=1.752500 probe: at 380.001,101.996 bed will contact at z=1.700000 probe: at 380.001,101.996 bed will contact at z=1.745000 probe: at 380.001,101.996 bed will contact at z=1.742500 probe: at 54.997,101.996 bed will contact at z=1.752500 probe: at 54.997,101.996 bed will contact at z=1.755000 probe: at 54.997,101.996 bed will contact at z=1.757500 probe: at 217.505,214.498 bed will contact at z=1.780000 probe: at 217.505,214.498 bed will contact at z=1.782500 01:20 means 1 full turn and 20 minutes, CW=clockwise, CCW=counter-clockwise front left screw (base) : x=72.0, y=298.0, z=1.78000 front right screw : x=397.0, y=298.0, z=1.75250 : adjust CCW 00:03 rear right screw : x=397.0, y=72.0, z=1.74250 : adjust CCW 00:04 rear left screw : x=72.0, y=72.0, z=1.75500 : adjust CCW 00:03 middle : x=234.5, y=184.5, z=1.78000 : adjust CCW 00:00